Search NASA⌕ Search

Engineering topics

Clark, A.

Publications and source records attributed to Clark, A..

At least 19 records

Criticality Experiments to Reduce Compensating Errors in Plutonium Nuclear Data

Compensating errors between nuclear data observables in a library can adversely impact application simulations. The primary goal of the EUCLID project (Experiments Underpinned by Computational Learning for Improvements in Nuclear Data) is to reduce compensating errors in nuclear data. A new criticality experiment, described in this work, was designed with the specific target nuclear data of 239 Pu fission, inelastic scattering, elastic scattering, capture, nu-bar, and prompt fission neutron spectrum (PFNS). This work will focus on the design and execution of the EUCLID experiment, performed on the Planet vertical lift critical assembly machine at the National Criticality Experiments Research Center (NCERC). The criticality experiment includes two different configurations with very different geometries: one is cube-like to minimize neutron leakage while the other is slab-like to maximize leakage. Having these two widely varying configurations allows the scattering sensitivities of 239 Pu to the neutron multiplication factor to be greatly changed while minimally impacting the other cross section sensitivities. Both configurations utilize the Pu ZPPR (Zero Power Physics Reactor) plates as fuel. The experiments were designed using a D-Optimality criteria, which is an optimization method minimizing the log-determinant of the adjusted nuclear data covariance for the target reactions. These experiments include not only inference of k eff , as done in all critical benchmark experiments, but several other responses as well, such as neutron multiplication measurements and reaction rate ratios. After analysis of the measured data is complete, adjustment of nuclear data will be performed to assess whether the new experimental data successfully reduced compensating errors.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Quantifying resonance behavior in the fusion of O 17 with C 12 at above-barrier energies

Recent measurement of the fusion excitation function for 17 O + 12 C reported the significant suppression of the fusion cross section at E c.m. ≈ 14 MeV. This suppression was hypothesized to signal the existence of a 16 O + n + 12 C molecular configuration. Using the active-target detector MuSIC@Indiana provided an effective means of reexamining the fusion excitation function for 17 O + 12 C.The accuracy of this thick-target measurement is strengthened through comparison with the thin-target measurement of the excitation function for 17 F + 12 C. Furthermore, the result provides important information about the dependence of the average fusion cross section for the oxygen isotopic chain on neutron excess.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Equivalent Fundamental-Mode Source Simulations for Spherical Uranium and Plutonium Systems [Abstract]

The equivalent fundamental-mode source refers to a “source” which is identically distributed in space, energy, and angle as that of a fundamental-mode fission source distribution. It has previously been shown that the system fixed source multiplication ($M_{fs}$) relates to the effective multiplication factor ($\kappa_{eff}$) as $M_{fs} = \frac{g^*}{1-k_{eff}}$ The term $\mathcal{g}$* therefore relates the system source distribution to the system equivalent fundamental-mode source. As previously shown, the $\mathcal{g}$* term is approximately 1 for deeply subcritical systems and then diverges as the system multiplication increases. For a system with a point source located in the center of an assembly (such a sphere), $\mathcal{g}$* will be greater than 1; this happens because there is a higher probability of induced fission when all of the starter neutrons originate from the center of the sphere. For a uniform source, $\mathcal{g}$* is less than 1, but does not diverge from 1 as dramatically as seen by a point source. One reason that $\mathcal{g}$* is an important parameter is that it is used in measurement methods to infer reactor kinetics parameters ($β_{eff}$ being one example). This work will discuss multiple ways to simulate $\mathcal{g}$* using MCNP®6.2, which include use of traditional methods versus a single input file method that was recently published. A discussion related to methods to simulate $M_{fs}$ will be presented. Spherical systems of Highly Enriched Uranium (HEU) will be compared with previous works. In addition, results of plutonium including multiple reflector materials will be investigated. Simulated systems will include both parametric studies as well as configurations used in recent experiments performed at the National Criticality Experiments Research Center (NCERC). These studies will include subtleties associated with system geometry that have not been previously shown. Last, this work will investigate the relationship between $\mathcal{g}$* and reactor kinetics parameters (such as $β_{eff}$).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

High-precision measurement of the W boson mass with the CDF II detector

The mass of the W boson, a mediator of the weak force between elementary particles, is tightly constrained by the symmetries of the standard model of particle physics. The Higgs boson was the last missing component of the model. After observation of the Higgs boson, a measurement of the W boson mass provides a stringent test of the model. We measure the W boson mass, M W , using data corresponding to 8.8 inverse femtobarns of integrated luminosity collected in proton-antiproton collisions at a 1.96 tera–electron volt center-of-mass energy with the CDF II detector at the Fermilab Tevatron collider. A sample of approximately 4 million W boson candidates is used to obtain M W = 80,433.5 ± 6.4 stat ± 6.9 syst = 80,433.5 ± 9.4 MeV/c 2 , the precision of which exceeds that of all previous measurements combined (stat, statistical uncertainty; syst, systematic uncertainty; MeV, mega–electron volts; c, speed of light in a vacuum). This measurement is in significant tension with the standard model expectation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Robust but weak winter atmospheric circulation response to future Arctic sea ice loss

The possibility that Arctic sea ice loss weakens mid-latitude westerlies, promoting more severe cold winters, has sparked more than a decade of scientific debate, with apparent support from observations but inconclusive modelling evidence. Here we show that sixteen models contributing to the Polar Amplification Model Intercomparison Project simulate a weakening of mid-latitude westerlies in response to projected Arctic sea ice loss. We develop an emergent constraint based on eddy feedback, which is 1.2 to 3 times too weak in the models, suggesting that the real-world weakening lies towards the higher end of the model simulations. Still, the modelled response to Arctic sea ice loss is weak: the North Atlantic Oscillation response is similar in magnitude and offsets the projected response to increased greenhouse gases, but would only account for around 10% of variations in individual years. We further find that relationships between Arctic sea ice and atmospheric circulation have weakened recently in observations and are no longer inconsistent with those in models.

54 ENVIRONMENTAL SCIENCES↗

Improving the characterization of fusion in a MuSIC detector by spatial localization

Multi-Sampling Ionization Chambers (MuSIC) provide an efficient means of measuring nuclear reactions with low beam rates (< 10 6 pps). However, in comparison to thin-target measurements, prior measurements using MuSIC detectors all manifest fusion excitation functions with wide error bars in the energy dimension. This uncertainty limits the applicability of these devices in measuring near and sub-barrier fusion cross-sections. Key to overcoming this limitation is spatial localization of the fusion in the detector. By comparing the measured ionization in the MuSIC detector with accurate energy loss calculations the position of the fusion in the detector is determined. The analysis not only provides the desired improvement in energy resolution, but it also allows extraction of the atomic number of the evaporation residues following fusion. Furthermore, the effectiveness of this approach is demonstrated for 18 O+ 12 C measured with MuSIC@Indiana.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MuSIC@Indiana: An effective tool for accurate measurement of fusion with low-intensity radioactive beams

The design, construction, and characterization of the Multi-Sampling Ionization Chamber, MuSIC@Indiana, are described. This detector provides efficient and accurate measurement of the fusion cross-section at near-barrier energies. The response of the detector to low-intensity beams of 17,18 O, 19 F, 23 Na, 24,26 Mg, 27 Al, and 28 Si at E lab 50–60MeV was examined. MuSIC@Indiana was commissioned by measuring the 18 O+ 12 C fusion excitation function for 11 < E cm < 20 MeV using CH 4 gas. Here, a simple, effective analysis cleanly distinguishes proton capture and two-body scattering events from fusion on carbon. With MuSIC@Indiana, measurement of 15 points on the excitation function for a single incident beam energy is achieved. The resulting excitation function is shown to be in good agreement with literature data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Production and integration of the ATLAS Insertable B-Layer

During the shutdown of the CERN Large Hadron Collider in 2013-2014, an additional pixel layer was installed between the existing Pixel detector of the ATLAS experiment and a new, smaller radius beam pipe. The motivation for this new pixel layer, the Insertable B-Layer (IBL), was to maintain or improve the robustness and performance of the ATLAS tracking system, given the higher instantaneous and integrated luminosities realized following the shutdown. Because of the extreme radiation and collision rate environment, several new radiation-tolerant sensor and electronic technologies were utilised for this layer. Furthermore, this paper reports on the IBL construction and integration prior to its operation in the ATLAS detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Observation of the Y (4140) structure in the J/ψΦ mass spectrum in B±→ J/ψΦK ± decays

Here, the observation of the $Y(4140)$ structure in $B^\pm\rightarrow J/\psi\,\phi K^\pm$ decays produced in $\bar{p} p $ collisions at $\sqrt{s}=1.96~TeV$ is reported with a statistical significance greater than 5 standard deviations. A fit to the $J/\psi\,\phi$ mass spectrum is performed assuming the presence of a Breit-Wigner resonance. The fit yields a signal of $19^{+6}_{-5}$ resonance events, and resonance mass and width of $4143.4^{+2.9}_{-3.0}(\mathrm{stat})\pm0.6(\mathrm{syst}) ~MeVcc$ and $15.3^{+10.4}_{-6.1}(\mathrm{stat})\pm2.5(\mathrm{syst})~MeVcc$ respectively. The parameters of this resonance-like structure are consistent with values reported from an earlier CDF analysis.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗