Neutron spectroscopy of plutonium using a handheld detection system

The ability to distinguish multiple forms of plutonium from one another, such as oxide and metal, is paramount in areas of nuclear nonproliferation and international safeguards. In its metal form, plutonium can be readily used in a nuclear weapon, while oxide forms are associated with nuclear reactor fuel. Oxide-based plutonium forms emit neutrons with an energy spectrum that is significantly different from the fission neutrons that are emitted from plutonium metal. Organic scintillation detectors output pulses that are proportional to the neutron energy deposited, and therefore present a means of distinguishing these plutonium forms based on their energy spectra. In this work, metal and oxide forms of plutonium were measured using a handheld detection system based on an organic glass scintillator. Monte Carlo modeling of these experiments was performed to provide insight into the origin of the features in the observed light output spectra. Through analysis of multiple regions of these spectra, in a matter of minutes we were able to unambiguously discriminate oxide and metal plutonium forms from one another and from a plutonium-beryllium neutron source, which was considered for comparison because these sources are commonly used in industrial applications. The ability to discriminate weapons-usable material from nuclear reactor fuel has applications in nuclear treaty verification and safeguards.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Dual particle imaging: Applications in security and environmental imaging

Radiation imaging detectors have been applied in a variety of fields for detection, localization and characterization of radioactive sources. In this work, we describe a handheld detection system (H2DPI) that can simultaneously image neutrons and gamma rays, and reconstruct the energy spectra of the incident particles. This system was applied to the detection and characterization of a plutonium metal source in experiments performed at the National Criticality Experiments Research Center, where the 4.5 kg plutonium source was placed approximately 60 cm from the H2DPI. Neutron and gamma-ray images were measured that show good agreement with the known location of the source. Furthermore, the H2DPI was also used to measure the neutron spectrum, which shows the expected shape of a Watt fission spectrum, and the gamma-ray energy spectrum, which shows the energies common to plutonium metal. Finally, we describe the application of the H2DPI in augmented reality, whereby real-time neutron and gamma-ray imaging data can be streamed to the Microsoft HoloLens to allow the user to visualize the source locations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gamma-ray imaging of Np-237 metal using an organic glass imager

Neutron and gamma-ray imaging systems are deployed within the field of nuclear safeguards for the detection and localization of special nuclear materials and other materials of interest. 237 Np is one of these materials of interest due its presence in spent nuclear fuel and potential for use in nuclear weapons when purified. Here, for the first time, a 6 kg neptunium sphere (98.8 wt% 237 Np) was measured using a dual-particle imager, from the University of Michigan, consisting of organic glass and inorganic scintillators. The novel composition of organic glass scintillator was recently developed at Sandia National Labs and has been used in particle imaging systems due to its time resolution and particle discrimination capabilities. Gamma-ray energy spectra from single and coincident events were extracted and the sequencing of Compton scatter and photoelectric absorption gamma-ray events was used to generate images using simple backprojection. The emissions of interest in this work are the 312 keV and 416 keV gamma rays from 233 Pa, a daughter isotope from the neptunium decay series. The results of this work show that there is close agreement between the true source location in angular space and the converged location from the gamma ray images created using the system. The gamma spectroscopy from single and coincident events also identified the characteristic emission from the daughter isotope and could be used to assist with the identification of 237 Np. Furthermore, successful localization of the source with 5 s of data demonstrates the practical application of the imaging system for imaging and detection of material in weapons-useable quantities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detecting and characterizing special nuclear material for nuclear nonproliferation applications

Abstract There is an urgent need for new, better instrumentation and techniques for detecting and characterizing special nuclear material (SNM), i.e., highly enriched uranium and plutonium. The development of improved instruments and techniques requires experiments performed with the SNM itself, which is of limited availability. This paper describes the findings of experiments performed at the National Criticality Experiments Research Center conducted using new instruments and techniques on unclassified, kg-quantity SNM objects. These experiments, performed in the framework of the Department of Energy, National Nuclear Security Administration Consortium for Monitoring, Technology, and Verification, focused on detecting, characterizing, and localizing SNM samples with masses ranging from 3.3 to 13.8 kg, including plutonium and highly enriched uranium using prototype detectors and techniques. The work demonstrates SNM detection and characterization using recently-developed prototype detection systems. Specifically, we present new results in passive detection and imaging of plutonium and uranium objects using gamma-ray and dual particle (fast neutron and gamma-ray) imaging. We also present a new analysis of the delayed neutron emissions during active interrogation of uranium using a neutron generator.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Prompt Photofission Neutron Detection in Depleted Uranium

The detection of prompt photofission neutrons during active interrogation is a strong indication of the presence of special nuclear materials. However, the high-energy photons used for interrogation create a very challenging radiation environment for the detection of prompt fission signatures. These challenges include detector saturation and pulse pile-up. Additionally, there is an elevated neutron background that further challenges the detection of prompt fission neutrons. This background is produced because of (γ, Xn) photonuclear reactions in the surrounding high-Z materials. Here, we demonstrate the detection of prompt photofission neutrons in these challenging environments. Depleted uranium (DU) and lead targets are interrogated with bremsstrahlung photons produced by a 9-MV electron linear accelerator. Fast neutrons are detected with trans-stilbene organic detectors, and scintillation pulses are analyzed using a previously developed and demonstrated artificial neural network system. We observe a 5 times higher photoneutron count rate when the lead target is replaced with the DU target. Additionally, we observe a difference in the photoneutron light-output distributions of lead and DU. Here, this difference in the measured distributions is due to the difference in the photoneutron-energy spectra; DU photoneutrons are emitted with (γ, n) and watt-energy spectra, whereas lead photoneutrons are emitted with only the (γ, n) spectrum.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

High-fidelity photoneutron detection via neutron activation analysis

To interdict illicit radioactive sources and prevent nuclear terror, governments have deployed portal monitor systems at ports of entry. Such portal monitors rely upon the detection of spontaneously-emitted radiation signatures, however, detection scenarios become more challenging for highly enriched uranium, which emits relatively few spontaneous radiation signatures. Photon active interrogation techniques can augment current cargo inspection scenarios and improve detection capabilities for illicit nuclear material. A high-energy photon interrogation source can induce photofission in nuclear material, producing strong radiation signatures for detection. Prompt fission signals are of specific interest because prompt neutrons are greater than 99% of the fission signal. When using detectors capable of spectroscopy, e.g., pulse shape discrimination-capable organic scintillators, the intense interrogating source often will cause pulse pile-up, degrading particle classification. In this work, we demonstrate photoneutron detection via neutron activation of aluminum and iron. The experiments rely upon nuclear reactions that can only be induced by neutrons, and are robust against pile-up, thereby providing high-confidence neutron rates. In this work, we apply neutron activation analysis for the detection of high-energy neutrons produced by high-energy photon irradiation; the depleted uranium sample was irradiated with a 9-MeV bremsstrahlung beam. We find that the irradiated depleted uranium produced an aluminum activation flux of 1.77 × 10 5 n cm –2 s –1 and an iron-56 activation flux of 1.05 × 10 5 n cm –2 s –1 . Furthermore, the ability to detect radioactivity induced by neutrons created in (, n) and photofission reactions demonstrates a new approach for photon active interrogation to identify nuclear materials.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An Artificial Neural Network System for Photon-Based Active Interrogation Applications

Active interrogation (AI) is a promising technique to detect shielded special nuclear materials (SNMs). At the University of Michigan, we are developing a photon-based AI system that uses bremsstrahlung radiation from an electron linear accelerator (linac) as an ionizing source and stilbene organic scintillating detectors for neutron detection. Stilbene scintillators are sensitive to fast neutrons and photons and have excellent pulse shape discrimination (PSD) capabilities. The traditional charge integration (CI) method commonly used for PSD analysis eliminates piled-up pulses and relies on a particle discrimination line to separate neutrons and photons. The presence of the intense photon flux during AI creates a significant number of piled-up events in the stilbene scintillator, thereby posing a great challenge to the traditional CI method. Identifying true single neutron pulses becomes challenging due to the presence of a pile-up cloud and overlapping neutron, photon and pile-up clouds in the PSD analysis. To mitigate the effect of pulse pile up and identify true single neutron pulses from stilbene scintillators, an artificial neural network (ANN) system is developed. The developed ANN system identifies single neutron pulses and neutron-photon combinations from piled-up events. The results obtained from a 252Cf measurement in the presence of the intense photon flux show that the developed ANN system outperforms the traditional CI method. Since many piled-up events lie above the particle discrimination line, they get misclassified as neutrons by the traditional CI method resulting in 25% overestimation of the net neutron count rate during the linac pulse. The overall net neutron count rate (single and restored neutrons) during the linac pulse, estimated by the ANN system is 60% of the ground truth. Energy spectroscopy of the ANN attributed single neutron pulses further provides evidence on the detection of prompt fission neutrons from the 252Cf fission source.

42 ENGINEERING↗

Fast Rossi-alpha Measurements of Plutonium Using Organic Scintillators

In this work, Rossi-alpha measurements were simultaneously performed with a 3 He-based detection system and an organic scintillator-based detection system. The assembly is 15 kg of plutonium (93 wt% 239 Pu) reflected by copper and moderated by lead. The goal of Rossi-alpha measurements is to estimate the prompt neutron decay constant, alpha. Simulations estimate $k_{eff}$ = 0:624 and α = 52:3 ± 2:5 ns for the measured assembly. The organic scintillator system estimated α = 47:4 ± 2:0 ns, having a 9.37% error (though the 1.09 standard deviation confidence intervals overlapped). The 3 He system estimated α = 37 μs. The known slowing down time of the 3 He system is 35-40 μs, which means the slowing down time dominates and obscures the prompt neutron decay constant. Subsequently, the organic scintillator system should be used for assemblies with alpha much less than 35 μs.

3He↗

DUAL-PARTICLE DOSEMETER BASED ON ORGANIC SCINTILLATOR

Abstract Traditionally available handheld dosemeters are generally sensitive to only one type of radiation: neutrons or photons. Some dosemeters also rely on very specific attenuation correlations between response and dose, are not scalable in size and multiple dosemeters are required to characterise mixed-particle fields. The research presented here serves as a proof-of-concept for a method to simultaneously measure dose rates from neutrons and photons using a particle discriminating organic scintillation detector without the need for spectral deconvolution. The method was compared with traditional instruments and to simulation. Isotopic photon dose rates measured with this method were within 4% of simulated truth, whereas fission spectrum neutron dose rates were measured within 21%. Measurements of dose rates from both particles agree with simulated truth better than traditional instruments. This new method allows for measurement of dose equivalent from both neutrons and photons with a single instrument and no reliance on spectral deconvolution.

Miller, C. A.↗

Angular distribution of neutron production by proton and carbon-ion therapeutic beams

Carbon-ion beams are increasingly used in the clinical practice for external radiotherapy treatments of deep-seated tumors. At therapeutic energies, carbon ions yield significant secondary products, including neutrons, which may be of concern for the radiation protection of the patient and personnel. We simulated the neutron yield produced by proton and carbon-ion pencil beams impinging on a clinical phantom at three different angles: 15°, 45° and 90°, with respect to the beam axis. We validated the simulated results using the measured response of organic scintillation detectors. We compared the results obtained with FLUKA 2011.2 and MCNPX 2.7.0 based on three different physics models: Bertini, Isabel, and CEM. Over the different ions, energies, and angles, the FLUKA simulation results agree better with the measured data, compared to the MCNPX results. Simulations of carbon ions at low angles exhibit both the highest deviation from measured data and inter-model discrepancy, which is probably due to the different treatment of the pre-equilibrium stage. The reported neutron yield results could help in the comparison of carbon-ion and proton treatments in terms of secondary neutron production for radiation protection applications.

60 APPLIED LIFE SCIENCES↗

Comparative Neutron Detection Efficiency in He-3 Proportional Counters and Liquid Scintillators

We present new results on the neutron detection efficiency of detection systems based on He-3 proportional counters compared to organic liquid scintillators. The experiments were conducted using a well-characterized Cf-252 neutron source, measured bare, and shielded with slabs of polyethylene. The results show that the intrinsic neutron detection efficiency for the bare source is approximately 25% for the He-3 system, and 67% for the liquid scintillator system. When polyethylene sheets were used to shield the source in 2.54 cm increments, the neutron detection efficiency of both systems decreased exponentially to approximately 10% for the case of 25.4 cm. Experimental results were simulated using MCNPX-PoliMi and good agreement was found between measurement and simulation results for all the cases considered here.

Organic scintillator, He-3, neutron detection, det↗

Shielding a monoenergetic photon source for nonproliferation applications analysis

Near-monoenergetic photon sources offer appealing improvements over broad-band bremsstrahlung sources when applied to challenges in nonproliferation efforts. The use of a laser-plasma accelerator offers electrons at the energies needed for multi-MeV Thomson sources in a compact form factor. Because these electrons have energy up to approximately 0.5 GeV, many energetic photons and neutrons are created as they are dumped out of the beam line. This fact creates challenges for performing experiments to demonstrate the advantages of such a photon source for nonproliferation applications in the short term, until effective methods for decelerating the electrons are developed. To mitigate these background particles for laboratory measurements, a system of beam dumps and secondary collimators has been designed. Once background flux is reduced to the lowest practical level, it is compared to the expected flux created by the source photon beam on a lead target. This simulation mimics a nonproliferation application by predicting measured flux off-axis from an interrogated high-Z object as a surrogate for special nuclear material. Background mitigation techniques are also expanded to a mobile interrogation case. Furthermore, these methods allow for demonstration of nonproliferation applications of near-monoenergetic photon sources and future deployment in the field.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fast-neutron multiplicity counter for active measurements of uranium oxide certified material

We developed a fast-neutron multiplicity counter (FNMC) based on stilbene and EJ-309 organic 11 scintillators. The system can detect and discriminate correlated photon and neutron multiplets emitted by fission 12 reactions. We used the system to estimate the fissile mass of uranium oxide samples in active interrogation mode at the 13 Zero Power Physics Reactor of Idaho National Laboratory (INL). Two sets of certified reference material (CRM) 14 samples were characterized. The U-235 enrichment of the first set is constant at 93.2 wt%, and the UO 2 mass ranges 15 between 0.5 and 4 kg. The second set includes samples of increasing enrichment (from 20 wt% to 97 wt%) and constant 16 UO 2 mass of 230 g. We used two AmLi sources to induce fission reactions in the samples. Despite the intense gamma17 ray background of the UO 2 and interrogating sources, the system could measure induced fission neutrons emerging from 18 the interrogated samples without additional shielding surrounding the sample and only relying on pulse shape 19 discrimination to classify neutron and gamma-ray pulses. Here, the overall neutron count rate and time-correlated counts are 20 well correlated with the sample fissile mass. We also proved that CRM samples can be used to build a calibration curve 21 to assay the U-235 mass of unknown samples of different mass, geometry and enrichment, with an average bias error of 22 8%, for U-235 mass higher than 390 g.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Artificial neural network algorithms for pulse shape discrimination and recovery of piled-up pulses in organic scintillators

We developed two neural-network (NN)-based algorithms (fully-connected neural network (Fc-NN) and recurrent neural network (RNN)) to perform pulse shape discrimination (PSD) and identification of piled-up pulses produced by organic scintillators, upon interaction with neutrons and gamma rays. We tested the algorithms on measured and verification sets of data and compared their classification performances to standard approaches. At a high acquisition count rate (100,000 counts per second, cps), in the presence of a gamma-to-neutron ratio of approximately 400–1, the proposed NN-based algorithm achieves a fraction of misclassified neutron, gamma, and piled-up pulses of approximately 1%, 1.8%, and 0.6%, respectively. Compared to the traditional approach, it exhibits 3×, 14×, and 11× improved (lower) miscalculation rates for neutron, gamma, and piled-up pulses, respectively. Here, we also demonstrate the capability of NN-based algorithms of successfully recovering and identifying neutron and gamma ray compositions from piled-up pulses in challenging, high pulse count rate conditions.

42 ENGINEERING↗

Energy resolution experiments of conical organic scintillators and a comparison with Geant4 simulations

An increase in light-collection efficiency (LCE) improves the energy resolution of scintillator-based detection systems. An improvement in energy resolution can benefit detector performance, for example by lowering the measurement threshold and achieving greater accuracy in light-output calibration. This work shows that LCE can be increased by modifying the scintillator shape to reduce optical-photon reflections, thereby decreasing transmission and absorption likelihood at the reflector boundary. The energy resolution of four organic scintillators (EJ200) were compared: two cones and two right-circular cylinders, all with equal base diameter and height (50 mm). The sides of each shape had two surface conditions: one was polished and the other was ground. Each scintillator was coupled to the center of four photomultiplier tube (PMT) configurations of different diameters. The photocathode response of all PMTs was assessed as a function of position using a small cube (5 mm height) of EJ200. The worst configuration, a highly polished conical scintillator mated to a PMT of equal base diameter, produced a smeared energy spectrum. The cause of spectrum smearing is explored in detail. Results demonstrate that a ground cone had the greatest improvement in energy resolution over a ground cylinder by approximately 16.2% at 478 keVee, when using the largest diameter (127 mm) PMT. Furthermore, this result is attributed to the greater LCE of the cone, its ground surface, and the uniform photocathode response near center of the largest PMT. Optical-photon transport simulations in Geant4 of the cone and cylinder assuming a diffuse reflector and a uniform photocathode were compared to the best experimental configuration and agreed well. If a detector application requires excellent energy resolution above all other considerations, a ground cone on a large PMT is recommended over a cylinder.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Correlated prompt fission data in transport simulations

Detailed information on the fission process can be inferred from the observation, modeling and theoretical understanding of prompt fission neutron and γ-ray observables. Beyond simple average quantities, the study of distributions and correlations in prompt data, e.g., multiplicity-dependent neutron and γ-ray spectra, angular distributions of the emitted particles, n -n, n - γ, and γ - γ correlations, can place stringent constraints on fission models and parameters that would otherwise be free to be tuned separately to represent individual fission observables. The FREYA and CGMF codes have been developed to follow the sequential emissions of prompt neutrons and γ rays from the initial excited fission fragments produced right after scission. Both codes implement Monte Carlo techniques to sample initial fission fragment configurations in mass, charge and kinetic energy and sample probabilities of neutron and γ emission at each stage of the decay. This approach naturally leads to using simple but powerful statistical techniques to infer distributions and correlations among many observables and model parameters. The comparison of model calculations with experimental data provides a rich arena for testing various nuclear physics models such as those related to the nuclear structure and level densities of neutron-rich nuclei, the γ-ray strength functions of dipole and quadrupole transitions, the mechanism for dividing the excitation energy between the two nascent fragments near scission, and the mechanisms behind the production of angular momentum in the fragments, etc. Beyond the obvious interest from a fundamental physics point of view, such studies are also important for addressing data needs in various nuclear applications. The inclusion of the FREYA and CGMF codes into the MCNP6.2 and MCNPX - PoliMi transport codes, for instance, provides a new and powerful tool to simulate correlated fission events in neutron transport calculations important in nonproliferation, safeguards, nuclear energy, and defense programs. Here, this review provides an overview of the topic, starting from theoretical considerations of the fission process, with a focus on correlated signatures. It then explores the status of experimental correlated fission data and current efforts to address some of the known shortcomings. Numerical simulations employing the FREYA and CGMF codes are compared to experimental data for a wide range of correlated fission quantities. The inclusion of those codes into the MCNP6.2 and MCNPX - PoliMi transport codes is described and discussed in the context of relevant applications. The accuracy of the model predictions and their sensitivity to model assumptions and input parameters are discussed. Lastly, a series of important experimental and theoretical questions that remain unanswered are presented, suggesting a renewed effort to address these shortcomings.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗