Search NASA⌕ Search

Engineering topics

Clay, R. W.

Publications and source records attributed to Clay, R. W..

26 records · Page 2

Observation of gamma-rays from LMC X-4 above 10(16) eV

Data from the University of Adelaide air shower array at Buckland Park taken over a three year period have been analyzed to search for evidence of ultra high energy gamma-ray emission from neutron star binary X-ray sources having known orbital periods. The detection of UHE gamma-rays from LMC X-4 above 10 to the 16th power eV, is reported; the first extragalactic object to be positively detected at these energies.

Protheroe, R. J.↗

EAS Cerenkov measurements of the composition of the cosmic ray flux around 10 to the 16th power eV

Information can be obtained about the nature of a primary cosmic ray by looking at the way in which an extensive air shower (EAS) develops in the atmosphere. Heavy nuclei give rise to showers that develop high in the atmosphere and the depth of maximum development is subjected to much smaller fluctuations than is the case for showers originating from protons. This development is followed by optical methods based on the observations of Cerenkov light or fluorescence light. The Cerenkov observations have two complementary techniques: measurement of the time profile of the Cerenkov pulse with resolution of a few nanoseconds and measurement of the lateral distribution of the Cerenkov light. In each case the measured quantities must be related to some characteristic development parameters.

Dawson, B. R.↗

Search for bursts in air shower data

There have been reports in recent years of the possible observation of bursts in air shower data. If such events are truly of an astrophysical nature then, they represent an important new class of phemonenon since no other bursts have been observed above the MeV level. The spectra of conventional gamma ray bursts are unknown at higher energies but their observed spectra at MeV energies appear generally to exhibit a steepening in the higher MeV range and are thus unlikely to extrapolate to measurable fluxes at air shower energies. An attempt has been made to look for deviations from randomness in the arrival times of air showers above approx. 10 to the 14th power eV with a number of systems and results so far are presented here. This work will be continued for a substantial period of ime with a system capable of recording bursts with multiple events down to a spacing of 4 microns. Earlier data have also been searched for the possible association of air shower events with a glitch of the Vela pulsar.

Bruce, T. E. G.↗

Air shower arrival directions measured at Buckland Park

The Buckland Park air shower array was operated for 3 years from 1979 to 1981 particularly for the study of anisotropies in the region of the knee of the size spectrum. The array which has been described in detail elsewhere was situated at a latitude of 35 S and had an effective size threshold of approx 3 x 10 to the 5th power particles (approx 3 x 10 to the 15th power Ev for vertical showers). A number of results from this experiment have already been published including anisotropy analyses (Gerhardy and Clay, 1983) and searches for very high energy gamma ray sources. The final distribution of measured shower arrival directions are presented here. These 1.3 x 10 to the 5th power events were selected as indicated in detail in Gerhardy and Clay (1983) and were essentially those events with well measured arrival directions. They are the same data set used in the above reference but no complete sky map has previously been presented.

Gerhardy, P. R.↗

Anisotropy and the knee of the energy spectrum

The measured cosmic ray energy spectrum exhibits clear structure (the knee) at approx 3 x 10 to the 15th power eV (sea level shower size approx 3 x 10 to the 5th power particles). Additionally, at energies in this general region, there occur apparent changes in shower development such that the observed characteristics of showers at this energy appear different to those characteristics observed at somewhat higher energies. At energies just below this region, the cosmic ray anisotropy amplitude apparently begins a progressive increase with energy. The latter effect does not clearly fit with the first two since there appears to be no significant change exactly at the knee. However, the phase of the first harmonic of the anisotropy appears to show a substantial change just where the energy spectrum shows structure and in the middle of the shower development changes. The first harmonic phase appears to change from approx. 18 hours R.A. to approx. 5 hours R.A. as the energy of observation moves through the knee. In this paper the latter change is examined in some detail by taking into account information contained in the second harmonic of the anisotropy.

Clay, R. W.↗

The Buckland Park air shower array

The new Buckland Park Air Shower Array has been producing analyzed shower data since July 1984. The array is described and some preliminary performance figures are presented.

Clay, R. W.↗

The longitudinal thickness of air-shower fronts

Linsely (1983) has proposed a technique for the detection and analysis of air showers at large distances from the shower axis based on a measurement of the shower front thickness and the assumption that this thickness is closely related to the core distance. Some of the problems involved with realizing such a technique were investigated, and some related observations are reported. The practical problems of how consistent the measurements of the shower front would be, how one would use the measurement, and how the rate of triggered events would depend on the minimum pulse width required are studied.

Clay, R. W.↗

A transient digitiser for fast air shower events

Air shower structure are often measured on time scales of a few nanoseconds. Longitudinal disk structure near the core is of the order of meters in dimension, air Cerenkov pulses have full widths at half maximum of the order of tens of nanoseconds, and fast timing over typical arrays is usually measured to nanosecond accuracy. oscilloscopes can be used but have very limited dynamic range and are expensive if measurements down to a few nanoseconds are to be made. For the fast Cerenkov work, an instrument with better dynamic range than an oscilloscope and with a time resolution sufficient to allow measurements limited only by system risetime of a few nanoseconds is needed. A 16/32 channel, 8 bit, fast transient digitizer was designed and built which runs at sample intervals down to approx. 1 nanosecond per channel.

Wild, N. R.↗