Search NASA⌕ Search

Engineering topics

Clowers, Kurt

Publications and source records attributed to Clowers, Kurt.

Improving Realism in Reduced Gravity Simulators

Since man was first determined to walk on the moon, simulating the lunar environment became a priority. Providing an accurate reduced gravity environment is crucial for astronaut training and hardware testing. This presentation will follow the development of reduced gravity simulators to a final comparison of environments between the currently used systems. During the Apollo program era, multiple systems were built and tested, with several NASA centers having their own unique device. These systems ranged from marionette-like suspension devices where the subject laid on his side, to pneumatically driven offloading harnesses, to parabolic flights. However, only token comparisons, if any, were made between systems. Parabolic flight allows the entire body to fall at the same rate, giving an excellent simulation of reduced gravity as far as the biomechanics and physical perceptions are concerned. While the effects are accurate, there is limited workspace, limited time, and high cost associated with these tests. With all mechanical offload systems only the parts of the body that are actively offloaded feel any reduced gravity effects. The rest of the body still feels the full effect of gravity. The Partial Gravity System (Pogo) is the current ground-based offload system used to training and testing at the NASA Johnson Space Center. The Pogo is a pneumatic type system that allows for offloaded motion in the z-axis and free movement in the x-axis, but has limited motion in the y-axis. The pneumatic system itself is limited by cylinder stroke length and response time. The Active Response Gravity Offload System (ARGOS) is a next generation groundbased offload system, currently in development, that is based on modern robotic manufacturing lines. This system is projected to provide more z-axis travel and full freedom in both the x and y-axes. Current characterization tests are underway to determine how the ground-based offloading systems perform, how they compare to parabolic flights, and which of the systems is preferable for specific uses. These tests were conducted with six degree of freedom robots and manual inputs. Initial results show a definitive difference in abilities of the two offload systems.

Cowley, Matthew↗

Effects of Varying Surface Inclines and Suit Pressure: Implications on Space Suit Design

Suited human performance studies in reduced gravity environments to date include limited observations from Apollo Lunar surface Extravehicular Activities (EVA) and from previous studies conducted in partial gravity simulation environments. The Constellation Program EVA Systems Project office has initiated tests to develop design requirements for the next generation Lunar EVA suit. Theses studies were conducted in the Space Vehicle Mock-Up Facility (SVMF) at Johnson Space Center from which the results provided recommendations for suit weight, mass, center of gravity, pressure, and suit kinematic constraints that optimize human performance in partial gravity environments.

Clowers, Kurt↗

Recent trends in digital human modeling and the concurrent issues that face human modeling approach

Tremendous strides have been made in the recent years to digitally represent human beings in computer simulation models ranging from assembly plant maintenance operations to occupants getting in and out of vehicles to action movie scenarios. While some of these tools are being actively pursued by the engineering communities, there is still a lot of work that remains to be done for the newly planned planetary exploration missions. For example, certain unique and several common challenges are seen in developing computer generated suited human models for designing the next generation space vehicle. The purpose of this presentation is to discuss NASA s potential needs for better human models and to show also many of the inherent yet not too obvious pitfalls that still are left unresolved in this new arena of digital human modeling. As part of NASA s Habitability and Human Factors Branch, the Anthropometry and Biomechanics Facility has been engaged in studying the various facets of computer generated human physical performance models; for instance, it has been engaged in utilizing three-dimensional laser scan data along with three dimensional video based motion and reach data to gather suited anthropometric and shape and size information that are not available yet in the form of computer mannequins. Our goal is to bring in new approaches to deal with heavily clothed humans (such as, suited astronauts) and to overcome the current limitations of wrongly identifying humans (either real or virtual) as univariate percentiles. We are looking at whole-body posture based anthropometric models as a means to identify humans of significantly different shapes and sizes to arrive at mathematically sound computer models for analytical purposes.

Rajulu, Sudhakar↗

A Mathematical Model to Predict and Maintain the Neutral Buoyancy of Suited Astronauts

A previous study reported that inadequate weigh outs of suited subjects contribute to fatigue and the risk of injury during training in the Neutral Buoyancy Laboratory (NBL). Another study suggested that shoulder injuries observed in suited subjects who train in the NBL may be attributed to excessive righting moments caused by a non-optimal weigh out. The purpose of this study was to develop a mathematical model to predict and maintain the neutral buoyancy of suited subjects during training operations at the NBL. Due to time constraints, one certified NBL support diver served as a subject (height: 66.54 in; weight: 182 lbs) for this study and only one complete test was conducted. The study was divided into two runs for which the first run required the NBL divers to perform a weigh out similar to a suited astronaut on a scuba diver wearing a mock Portable Life Support System and a Displays and Control Module. For the second run, the same subject and equipment were weighed out according to the mathematical model. The objective of each run was to achieve a neutrally buoyant subject floating 450 to the pool floor. Motion data was collected using two underwater cameras and analyzed using Dartfish video analysis software while force and moment data were recorded using an AMTI force plate. The results from the NBL divers visual run indicate that the subject was floating at an angle of 29.50 while the resultant force and moment data were 1.139 lb and 1.125 ft-lb respectively. The mathematical model s weigh out resulted in the subject floating at an angle of 37.40 and a resultant force of 0.765 lb and resultant moment of 1.248 ft-lb. The mathematical model was better able to orient the subject and reduce resultant moment and force as compared to the NBL divers.

Clowers, Kurt↗

Morphing: A Novel Approach to Astronaut Suit Sizing

The fitting of a spacesuit to an astronaut is an iterative process consisting of two parts. The first uses anthropometric data to provide an approximation of the suit components that will fit the astronaut. The second part is the subjective fitting, where small adjustments are made based on the astronaut s preference. By providing a better approximation of the correct suit components, the entire fit process time can be reduced significantly. The goals of this project are twofold: (1) To evaluate the effectiveness of the existing sizing algorithm for the Mark III Hybrid suit and (2) to determine what additional components are needed in order to provide adequate sizing for the existing astronaut population. A single subject was scanned using a 3D whole-body scanner (VITUS 3D) in the Mark III suit in eight different poses and four subjects in minimal clothing were also scanned in similar poses. The 3D external body scans of the suit and the subject are overlaid and visually aligned in a customized MATLAB program. The suit components were contracted or expanded linearly along the subjects limbs to match the subjects segmental lengths. Two independent measures were obtained from the morphing program on four subjects and compared with the existing sizing information. Two of the four subjects were in correspondence with the sizing algorithm and morphing results. The morphing outcome for a third subject, incompatible with the suit, suggested that an additional arm element at least 6 inches smaller than the existing smallest suit component would need to be acquired. The morphing result of the fourth subject, deemed incompatible with the suit using the sizing algorithm, indicated a different suit configuration which would be compatible. This configuration matched with the existing suit fit check data.

Margerum, Sarah↗