Search NASA⌕ Search

Engineering topics

Coffee, Ryan N.

Publications and source records attributed to Coffee, Ryan N..

Machine Learning for Real-time Fusion Plasma Behavior Prediction and Manipulation

This project set out with an ambitious goal: to develop and apply machine learning-based methods of discovering new controllers and operating regimes for achieving better performing plasmas in tokamaks. As summarized in the dozens of papers below, the project was a huge success. It developed several machine learning components and integrated them into a single ML system that was added to the DIII-D PCS. That functionality was demonstrated over a series of experiments on DIII-D. A summary of these results is given here with the details in the published papers below.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Attosecond coherent electron motion in Auger-Meitner decay

In quantum systems, coherent superpositions of electronic states evolve on ultrafast time scales (few femtoseconds to attoseconds; 1 attosecond = 0.001 femtoseconds = 10 -18 seconds), leading to a time-dependent charge density. Here we performed time-resolved measurements using attosecond soft x-ray pulses produced by a free-electron laser, to track the evolution of a coherent core-hole excitation in nitric oxide. Using an additional circularly polarized infrared laser pulse, we created a clock to time-resolve the electron dynamics and demonstrated control of the coherent electron motion by tuning the photon energy of the x-ray pulse. Core-excited states offer a fundamental test bed for studying coherent electron dynamics in highly excited and strongly correlated matter.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A self-referenced in-situ arrival time monitor for X-ray free-electron lasers

We present a novel, highly versatile, and self-referenced arrival time monitor for measuring the femtosecond time delay between a hard X-ray pulse from a free-electron laser and an optical laser pulse, measured directly on the same sample used for pump-probe experiments. Two chirped and picosecond long optical supercontinuum pulses traverse the sample with a mutually fixed time delay of 970 fs, while a femtosecond X-ray pulse arrives at an instant in between both pulses. Behind the sample the supercontinuum pulses are temporally overlapped to yield near-perfect destructive interference in the absence of the X-ray pulse. Stimulation of the sample with an X-ray pulse delivers non-zero contributions at certain optical wavelengths, which serve as a measure of the relative arrival time of the X-ray pulse with an accuracy of better than 25 fs. We find an excellent agreement of our monitor with the existing timing diagnostics at the SACLA XFEL with a Pearson correlation value of 0.98. We demonstrate a high sensitivity to measure X-ray pulses with pulse energies as low as 30 μJ. Using a free-flowing liquid jet as interaction sample ensures the full replacement of the sample volume for each X-ray/optical event, thus enabling its utility even at MHz repetition rate XFEL sources.

47 OTHER INSTRUMENTATION↗

Ionizing photon interactions modulate the optical properties of crystals with femtosecond scale temporal resolution

In this work, we continue our study of a new method for the detection of ionizing radiation with the potential for a dramatic improvement in coincidence time resolution (CTR) for time-of-flight positron emission tomography (ToF-PET) using the modulation of a material's optical properties instead of the scintillation mechanism. Our previous work has shown that for non-scintillation materials such as bismuth silicon oxide (BSO) and cadmium telluride (CdTe), their refractive index can be modulated by annihilation photon interactions. Additionally, the ultrafast nature of this process however remains unexplored. The ionizing radiation-induced charge carriers alter the local band structure in these materials, thus changing the complex refractive index. This mechanism is routinely used at the linac coherent light source (LCLS) facility of the SLAC National Accelerator Laboratory to measure x-ray pulse arrival times with femtosecond scale resolution for photon energies between 0.5 and 10 keV. The method described here follows that example by using a frequency chirped visible continuum pulse to provide a monotonic wavelength-to-time mapping by which one can measure the time-dependent refractive index modulation. In addition, we describe an interference-based measurement setup that allows for significantly improved sensitivity while preserving a timing precision of approximately 10 fs (σ) when measuring the arrival time of below 10 keV x-ray pulses with yttrium aluminum garnet (YAG) crystal. The method is presented in the context of ToF-PET application with further discussions on the potential CTR achievable if a similar detection concept is adopted for detecting 511 keV photons. Semi-empirical analysis indicates that the predicted CTR achievable is on the order of 1 ps (FWHM).

59 BASIC BIOLOGICAL SCIENCES↗