Search NASASearch

Engineering topics

Cole, R.

Publications and source records attributed to Cole, R..

At least 19 records

Performance of the PRAXyS X-Ray Polarimeter

The performance of the Time Projection Chamber (TPC) polarimeter for the Polarimeter for Relativistic Astrophysical X-ray Sources (PRAXyS) Small Explorer was evaluated using polarized and unpolarized X-ray sources. The PRAXyS mission will enable exploration of the universe through X-ray polarimetry in the 2-10 keV energy band. We carried out performance tests of the polarimeter at the Brookhaven National Laboratory, National Synchrotron Light Source (BNL-NSLS) and at NASA's Goddard Space Flight Center. The polarimeter was tested with linearly polarized, monochromatic X-rays at 11 different energies between 2.5 and 8.0 keV. At maximum sensitivity, the measured modulation factors at 2.7, 4.5 and 8.0 keV are 27%, 43% and 59%, respectively and the measured angle of polarization is consistent with the expected value at all energies. Measurements with a broadband, unpolarized X-ray source placed a limit of less than 1% on false polarization in the PRAXyS polarimeter.

PRAXyS

The LOFT Mission Concept - A Status Update

The Large Observatory For x-ray Timing (LOFT) is a mission concept which was proposed to ESA as M3 and M4 candidate in the framework of the Cosmic Vision 2015-2025 program. Thanks to the unprecedented combination of effective area and spectral resolution of its main instrument and the uniquely large field of view of its wide field monitor, LOFT will be able to study the behaviour of matter in extreme conditions such as the strong gravitational field in the innermost regions close to black holes and neutron stars and the supra-nuclear densities in the interiors of neutron stars. The science payload is based on a Large Area Detector (LAD, is greater than 8m2 effective area, 2-30 keV, 240 eV spectral resolution, 1 degree collimated field of view) and a Wide Field Monitor (WFM, 2-50 keV, 4 steradian field of view, 1 arcmin source location accuracy, 300 eV spectral resolution). The WFM is equipped with an on-board system for bright events (e.g., GRB) localization. The trigger time and position of these events are broadcast to the ground within 30 s from discovery. In this paper we present the current technical and programmatic status of the mission.

Silicon detectors

Bubble trajectories in rotating drops

The investigation summarized in this paper describes recent normal gravity experiments involving the behavior of compound drops in rotating flows and in particular, the subsequent migration of the less dense phase (air bubble) toward the rotation axis. The data are compared to two models. The first was developed to predict the trajectory of a fluid particle in an infinitely large drop in the presence of both gravitational and rotational fields at the limit of quasi-steady creeping flow. The second predicts the trajectory of a fluid particle in a compound drop in the presence of a rotational field and at the limit of creeping flow. Gravity has not yet been incorporated into this second model.

Brone, D.

Bubble and drop trajectories in rotating flows

The migration of bubbles or drops in a rotating liquid-filled sphere was observed under a variety of experimental conditions, and the trajectory, final equilibrium position, and shape were compared with results of analysis. It was found that small migrating bubbles or drops were spherical and, under the quasi-steady conditions employed, behaved in a predictable manner. Large migrating bubbles were nonspherical yet still behaved predictably except when close to the sphere wall. At low rotation rates, the final equilibrium position was offset from the rotation axis and stationary in the rotating liquid relative to a laboratory (inertial) reference frame. One of the bubble migration experiments was accomplished in the near-free-fall environment provided by the NASA KC-135 flight program. At higher rotation rates and under zero gravity conditions where the rotation axis is the final equilibrium position, the shape was reasonably predictable.

Ruggles, J. S.

Microgravity bubble migration in rotating flows

The NASA KC-135 microgravity-environment aircraft was used to gather experimental data on the migration of bubbles in rotating liquid fields under reduced gravity conditions. The data thus obtained were compared to those of an analysis for the prediction of fluid particle trajectories in the presence of both gravitational and rotational fields at the limit of quasi-steady creeping flow. Reasonable agreement with experimental results was achieved, despite the large size of the bubbles, their close proximity to a bounding surface over significant portions of their migration time, and their rather nonspherical geometry.

Ruggles, J. S.

Particle migration in rotating liquids

An analytical solution predicting the behavior of particles in the presence of both gravitational and rotational fields is obtained at the limit of quasi-steady creeping flow. The experiments performed in the present work using fluid particles, as well as the experiments already reported on solid particles, agree satisfactorily with the theory.

Annamalai, P.

Physical Phenomena in Containerless Glass Processing

An investigation into the various physical phenomena of importance in the space experiments is under way. Theoretical models of thermocapillary flow in drops, thermal migration of bubbles and droplets, the motion of bubbles inside drops, and the migration of bubbles in rotating liquid bodies are being developed. Experiments were conducted on the migration of bubbles and droplets to the axis of a rotating liquid body, and the rise of bubbles in molten glass. Also, experiments on thermocapillary motion in silicone oils as well as glass melts were performed. Experiments are currently being conducted on the migration of bubbles in a thermal gradient, and on their motion inside unconstrained liquid drops in a rotating liquid.

Subramanian, R. S.

Experimental studies of glass refining

The basic components of the experimental apparatus were selected and acquired. Techniques were developed for the fabrication of the special crucibles necessary for the experiments. Arrangements were made for the analysis of glass and gas bubble samples for composition information. Donations of major equipment were received for this project from Owens, Illinois where a similar study had been conducted a few year ago. Decisions were made regarding the actual glass composition to be used, the gas to be used in the first experiments, and the temperatures at which the experiments should be conducted. A microcomputer was acquired, and work was begun on interfacing the video analyzer to it.

Subramanian, R. S.

Drop motion in a rotating immiscible liquid body

The interaction of liquids is an important part of many processes and is often used for such purposes as causing a separation of solution components by mass transfer between phases, allowing a chemical reaction between liquids or their components, providing direct contact heating or cooling, or creating emulsions. Containerless space processing may well involve the interaction of liquids in the form of drops. For example it may be desirable to form an alloy in space by merger of two or more drops. Encapsulation of a volatile liquid by a second less volatile and immiscible liquid might be a means for avoiding volatilization. Rotation of such systems would enhance mixing where desirable and/or provide means for drop management. In this study, single drop behavior in rotating liquid bodies is studied experimentally.

Annamalai, P.

Motion driven by the interface

Due to the reduction in buoyant forces aboard orbiting spacecraft such as the Space Shuttle, fluid motion driven by gradients in interfacial tension will be important in the processing of materials in space. In this paper, preliminary results from a study of surface tension driven flow in a pendant drop are reported. The drop is heated from above, and the resulting temperature gradients on the drop surface give rise to interfacial tension gradients. These, in turn, drive a circulation in the drop which is made visible by suitable tracers. The velocities are measured using a video technique, and the data on core velocities are found to agree well with results from a predictive theoretical model.

Jayaraj, K.

Bubble migration in a rotating, liquid-filled sphere

Results and analysis of ground-based experiments performed to aid in designing experiments on the behavior of bubbles in a rotating liquid body on board the Shuttle in free fall are presented. Spherical shells filled with silicone oil containing a small gas bubble were spun and filmed by high speed motion picture photography. The rotation of the shell and the trajectory of the bubble motion were recorded and the film was exposed to a motion analyzer connected to a keypunch. The analyzer measured Cartesian coordinates as well as angle, frame number, and rotation rate. Optical correction equations were employed to determine the apparent bubble trajectory relative to an inertial frame of reference. An analytical model for the bubble motion was defined, yielding predictions of velocity and position at different times. Rotation of the fluid container is concluded to aid in centering the bubbles.

Annamalai, P.

The motion of bubbles inside drops in containerless processing

A theoretical model of thermocapillary bubble motion inside a drop, located in a space laboratory, due to an arbitrary axisymmetric temperature distribution on the drop surface was constructed. Typical results for the stream function and temperature fields as well as the migration velocity of the bubble were obtained in the quasistatic limit. The motion of bubbles in a rotating body of liquid was studied experimentally, and an approximate theoretical model was developed. Comparison of the experimental observations of the bubble trajectories and centering times with theoretical predictions lends qualified support to the theory.

Shankar, N.

Physical phenomena in containerless glass processing

Experiments were conducted on bubble migration in rotating liquid bodies contained in a sphere. Experiments were initiated on the migration of a drop in a slightly less dense continuous phase contained in a rotating sphere. A refined apparatus for the study of thermocapillar flow in a glass melt was built, and data were acquired on surface velocities in the melt. Similar data also were obtained from an ambient temperature fluid model. The data were analyzed and correlated with the aid of theory. Data were obtained on flow velocities in a pendant drop heated from above. The motion in this system was driven principally by thermocapillarity. An apparatus was designed for the study of volatilization from a glass melt.

Subramanian, R. S.

Bubble migration inside a liquid drop in a space laboratory

The design of experiments in materials processing for trials on board the Shuttle are described. Thermocapillary flows will be examined as an aid to mixing in the formation of glasses. Acoustically levitated molten glass spheres will be spot heated to induce surface flow away from the hot spot to induce mixing. The surface flows are also expected to cause internal convective motion which will drive entrained gas bubbles toward the hot spot, a process also enhanced by the presence of thermal gradients. The method is called fining, and will be augmented by rotation of the sphere to cause bubble migration toward the axes of rotation to form one large bubble which is more easily removed. Centering techniques to fix the maximum centering accuracy will also be tried. Ground-based studies of bubble migration in a rotating liquid and in a temperature gradient in a liquid drop are reviewed.

Annamalai, P.

Bubble motion in a rotating liquid body

The behavior of a single gas bubble inside a rotating liquid-filled sphere has been investigated analytically and experimentally as part of ground-based investigations aimed at aiding in the design and interpretation of Shuttle experiments. In the analysis, a quasi-static description of the motion of a bubble was developed in the limit of small values of the Taylor number. A series of rotation experiments using air bubbles and silicone oils were designed to match the conditions specified in the analysis, i.e., the bubble size, sphere rotation rate, and liquid kinematic viscosity were chosen such that the Taylor number was much less than unity. The analytical description predicts the bubble velocity and its asymptotic location. It is shown that the asymptotic position is removed from the axis of rotation.

Annamalai, P.

Thermocapillary motion of bubbles inside drops

A quasi-static analysis is performed for the thermocapillary motion of a bubble located inside a drop in free fall, with arbitrary axisymmetric temperature fields prescribed on the drop surface. It is shown that in the case of an axially symmetric temperature field, the bubble moves along the axis of symmetry toward the nearest warm pole. The bubble velocity as well as the velocity and temperature fields in the drop can be predicted on the basis of the quasi-static assumptions. An approximation is presented which adequately describes bubble migration velocities in the case where the ratio of the bubble radius to the drop radius is relatively small.

Shankar, N.

Surface tension driven flow in glass melts and model fluids

Surface tension driven flow has been investigated analytically and experimentally using an apparatus where a free column of molten glass or model fluids was supported at its top and bottom faces by solid surfaces. The glass used in the experiments was sodium diborate, and the model fluids were silicone oils. In both the model fluid and glass melt experiments, conclusive evidence was obtained to prove that the observed flow was driven primarily by surface tension forces. The experimental observations are in qualitative agreement with predictions from the theoretical model.

Mcneil, T. J.