Free-free and fixed base modal survey tests of the Space Station Common Module Prototype

This paper describes the testing aspects and the problems encountered during the free-free and fixed base modal surveys completed on the original Space Station Common Module Prototype (CMP). The CMP is a 40-ft long by 14.5-ft diameter 'waffle-grid' cylinder built by the Boeing Company and housed at the Marshall Space Flight Center (MSFC) near Huntsville, AL. The CMP modal survey tests were conducted at MSFC by the Dynamics Test Branch. The free-free modal survey tests (June '90 to Sept. '90) included interface verification tests (IFVT), often referred to as impedance measurements, mass-additive testing and linearity studies. The fixed base modal survey tests (Feb. '91 to April '91), including linearity studies, were conducted in a fixture designed to constrain the CMP in 7 total degrees-of-freedom at five trunnion interfaces (two primary, two secondary, and the keel). The fixture also incorporated an airbag off-load system designed to alleviate the non-linear effects of friction in the primary and secondary trunnion interfaces. Numerous test configurations were performed with the objective of providing a modal data base for evaluating the various testing methodologies to verify dynamic finite element models used for input to coupled load analysis.

Driskill, T. C.

Modal survey testing of the Lidar In-space Technology Experiment (LITE) - A Space Shuttle payload

This paper presents the results of the modal survey test of the Lidar In-space Technology Experiment (LITE), a Space Shuttle payload mounted in a Spacelab flight single pallet. The test was performed by the Dynamics Test Branch at Marshall Space Flight Center, AL and run in two phases. In the first phase, an unloaded orthogrid connected to the pallet with 52 tension struts was tested. This test included 73 measurement points in three directions. In the second phase, the pallet was integrated with mass simulators mounted on the flight support structure to represent the dynamics (weight and center of gravity) of the various components comprising the LITE experiment and instrumented at 213 points in 3 directions. The test article was suspended by an air bag system to simulate a free-free boundary condition. This paper presents the results obtained from the testing and analytical model correlation efforts. The effect of the suspension system on the test article is also discussed.

Anderson, J. B.

A mass additive technique for modal testing as applied to the Space Shuttle ASTRO-1 payload

Traditionally, a fixed base modal test has been performed as a means of verifying the coupled loads math model for Space Shuttle flight payloads. An alternate method, a free-free configured payload using mass loaded boundary conditions, is presented as a means of verifying the coupled loads model of the ASTRO-1 flight payload. This method allows evaluation of the influence of local load paths into the frequency range of the free-free test. The method is cost effective and does not contaminate the modal test results with fixture coupled modes or boundary condition uncertainties. This paper describes the mass additive modal test technique as applied to the Space Shuttle ASTRO-1 flight payload.

Coleman, A. D.

Insulation Debond Detection

Load-cell and acoustic responses indicate bonding condition nondestructively. Signal recorded by load cell direct and instantaneous measure of local stiffness of material at point of impact. Separate and distinctly different measurement that sensed by microphone. Spectrum analysis of pulse obtained from debonded point will only show frequencies below 425 Hz because insulation alone does not have stiffness to support energy at higher frequencies.

Johnston, G. D.

Insulation bonding test system

A method and a system for testing the bonding of foam insulation attached to metal is described. The system involves the use of an impacter which has a calibrated load cell mounted on a plunger and a hammer head mounted on the end of the plunger. When the impacter strikes the insulation at a point to be tested, the load cell measures the force of the impact and the precise time interval during which the hammer head is in contact with the insulation. This information is transmitted as an electrical signal to a load cell amplifier where the signal is conditioned and then transmitted to a fast Fourier transform (FFT) analyzer. The FFT analyzer produces energy spectral density curves which are displayed on a video screen. The termination frequency of the energy spectral density curve may be compared with a predetermined empirical scale to determine whether a igh quality bond, good bond, or debond is present at the point of impact.

Beggs, J. M.

Modal test of Shuttle engine nozzle

A structural failure occurred on the main propulsion test stand at NSTL causing a hydrogen fire and damage to the engines to be used on the Orbiter Columbia. Scattered accelerometer measurements indicated very high response levels at 254 hertz and 311 hertz. The Engine Office at MSFC asked the Dynamics Test Branch to try and find out what caused the failure. All three nozzles were sent to Huntsville for testing. Modal test data revealed very quickly how the failure occurred in the steerhorn and also pointed out two other structural problems. A complete set of data is presented along with a narrative explanation of the steps taken to identify and verify the structural problem.

Johnston, G. D.