Crossflow vortex and transition measurements by use of multielement hot films
Explore the source record for details and available documents.
Engineering topics
Publications and source records attributed to Collier, Fayette S., Jr..
Explore the source record for details and available documents.
Consideration is given to the potential application of hybrid-laminar-flow control to the external surface of a modern, high-bypass-ratio (HBR) turbofan engine nacelle. With the advent of advanced ultra-HBR fans (with bypass ratios of 10-15), the wetted areas of these nacelles approach 10 percent of the total wetted area of future commercial transports. A hybrid-laminar-flow-control pressure distribution is specified and the corresponding nacelle geometry is computed utilizing a predictor/corrector design method. Linear stability calculations are conducted to provide predictions of the extent of the laminar boundary layer. Performance studies on an advanced twin-engine transport configuration are presented to determine potential benefits in terms of reduced fuel consumption.
An experiment on a 45-degree swept wing was conducted to study three-dimensional boundary-layer characteristics using surface-mounted, micro-thin, multi-element hot-film sensors. Cross-flow vortex structure and boundary-layer transition were measured from the simultaneously acquired signals of the hot films. Spanwise variation of the root-mean-square (RMS) hot-film signal show a local minima and maxima. The distance between two minima corresponds to the stationary cross-flow vortex wavelength and agrees with naphthalene flow-visualization results. The chordwise and spanwise variation of amplified traveling (nonstationary) cross-flow disturbance characteristics were measured as Reynolds number was varied. The frequency of the most amplified cross-flow disturbances agrees with linear stability theory.
For the case of the F-15 flight tests, boundary layer transition was observed up to Mach numbers of 1.2. For very limited and specific flight conditions, laminar flow existed back to about 20 percent chord on the surface clean up glove. Hot film instrumentation was effective for locating the region of transition. For the F-106 flight tests, transition on the wing or vertical tail generally occurred very near the attachment line. Transition was believed to be caused by either attachment line contamination or strong cross flow development due to the high sweep angles of the test articles. The compressibility analysis showed that cross flow N-factors were in the range of 5 to 12 at transition.