Engineering topics
Colombo, Anthony P.
Publications and source records attributed to Colombo, Anthony P..
Four-channel optically pumped atomic magnetometer for magnetoencephalography
We have developed a four-channel optically pumped atomic magnetometer for magnetoencephalography (MEG) that incorporates a passive diffractive optical element (DOE). The DOE allows us to achieve a long, 18-mm gradiometer baseline in a compact footprint on the head. Using gradiometry, the sensitivities of the channels are < 5 fT/Hz 1/2 , and the 3-dB bandwidths are approximately 90 Hz, which are both sufficient to perform MEG. Additionally, the channels are highly uniform, which offers the possibility of employing standard MEG post-processing techniques. As a result, this module will serve as a building block of an array for magnetic source localization.
Micro-fabricated ion traps for Quantum Information Processing; Highlights and lessons learned.
Abstract not provided.
Towards a Multi-Channel Atomic Magnetometer Array for MEG.
Abstract not provided.
Micro-fabricated ion traps for Quantum Information Processing.
Abstract not provided.
Development of an Optically Pumped Atomic Magnetometer Array for Magnetoencephalography.
Abstract not provided.
Towards a Multi-Channel Atomic Magnetometer Array for MEG.
Abstract not provided.
Progress toward a multi-channel magnetoencephalography system using optically pumped atomic magnetometers.
Abstract not provided.
Atomic Magnetometers for Magnetoencephalography Design and Construction of a 36-Channel System.
Abstract not provided.
Chirped-pulse millimeter-wave spectroscopy: Spectrum, dynamics, and manipulation of Rydberg-Rydberg transitions
We apply the chirped-pulse millimeter-wave (CPmmW) technique to transitions between Rydberg states in calcium atoms. The unique feature of Rydberg-Rydberg transitions is that they have enormous electric dipole transition moments ({approx}5 kiloDebye at n*{approx} 40, where n* is the effective principal quantum number), so they interact strongly with the mm-wave radiation. After polarization by a mm-wave pulse in the 70-84 GHz frequency region, the excited transitions re-radiate free induction decay (FID) at their resonant frequencies, and the FID is heterodyne-detected by the CPmmW spectrometer. Data collection and averaging are performed in the time domain. The spectral resolution is {approx}100 kHz. Because of the large transition dipole moments, the available mm-wave power is sufficient to polarize the entire bandwidth of the spectrometer (12 GHz) in each pulse, and high-resolution survey spectra may be collected. Both absorptive and emissive transitions are observed, and they are distinguished by the phase of their FID relative to that of the excitation pulse. With the combination of the large transition dipole moments and direct monitoring of transitions, we observe dynamics, such as transient nutations from the interference of the excitation pulse with the polarization that it induces in the sample. Since the waveform produced by the mm-wave source may be precisely controlled, we can populate states with high angular momentum by a sequence of pulses while recording the results of these manipulations in the time domain. We also probe the superradiant decay of the Rydberg sample using photon echoes. The application of the CPmmW technique to transitions between Rydberg states of molecules is discussed.