Search NASA⌕ Search

Engineering topics

Conel, James E.

Publications and source records attributed to Conel, James E..

At least 37 records · Page 2

Inflight Calibration of AVIRIS in 1992 and 1993

In order to pursue the quantitative research objective of AVIRIS, the spectral, radiometric characteristic of the sensor must be known at the time of flight data acquisition. AVIRIS is rigorously calibrated in the laboratory. In addition, three times each year these characteristics of AVIRIS are validated through an inflight calibration experiment. Absolute radiometric calibration and signal-to-noise results are present for the inflight calibration experiment orchestrated in 1992 and 1993.

Chrien, Tom↗

Application of Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) to Determination of Atmospheric Aerosol Optical Depth and Precipitable Water Content

This paper focuses on determination of the temporal and spatial gas absorption and aerosol scattering properties of the atmosphere itself including the radiative properties of clouds, specifically derivation of estimates of aerosol optical depth, atmospheric water vapor, and oxygen pressure surface altitude form upwelling near-TOA spectral radiance measurements obtained with the AVIRIS.

Remote SensingAVIRIS↗

Recovery of atmospheric water vapor total column abundance from imaging spectrometer data around 940 nm - Sensitivity analysis and application to Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) data

Two simple techniques (Continuum Interpolated Band Ratio, CIBR, and Narrow/Wide ratio, N/W) to retrieve path precipitable water from AVIRIS high spectral resolution radiance data using the 940 nm water absorption band are compared. A sensitivity analysis was performed using the radiative transfer code LOWTRAN 7 to determine which one of these two approaches will provide a better estimate over land and water areas. The CIBR proved to be the technique less sensitive to perturbing effects, except for errors in visibility estimate. Both techniques were applied to AVIRIS radiance data acquired over Salton Sea, California. Resulting images confirmed that the use of a constant gray reflectance in the model led to a higher overestimation of the amount of water retrieved for N/W over vegetated areas. Validation was performed through comparison between an independent estimate of water vapor from concurrent Reagan sunphotometer measurements and AVIRIS estimates. Amounts retrieved using the N/W approach match more closely in situ measurements, even after adjusting model parameters for background reflectance, viewing geometry, and type of aerosol at the site.

Carrere, Veronique↗

Water vapor column abundance retrievals during FIFE

A variation of the modified Langley plot algorithm is reported here and applied to the retrieval of atmospheric water column abundance from a filtered sunphotometer. In this new methodology an absorption data base (LOWTRAN 7) is used to compute a water abundance versus transmittance curve of growth, rather than the square-root dependence previously assumed. Validation of the technique is provided from an uncertainty analysis, and plans to further validate using Fourier transform spectrometers are detailed. The new sunphotometer technique is used to report local column water vapor during the First ISLSCP Field Experiment (FIFE), and comparisons are made with abundances retrieved via FIFE radiosonde observations. The sunphotometer data can best be utilized, however, to in turn validate data from airborne or in-orbit measurements of water vapor. With these flight sensors, horizontal and topographic variability within the scene can be viewed. An example of the airborne data set is given using an image from the airborne visible infrared imaging spectrometer, as acquired on August 31, 1990.

Bruegge, Carol J.↗

In-flight calibration of the spectral and radiometric characteristics of AVIRIS in 1991

On 7 Mar. 1991, an in-flight calibration experiment was held at the Ivanpah Playa in southeastern California for the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) imaging spectrometer. Five AVIRIS overflights were acquired of a calibration target designated on the Ivanpah Playa surface. At the time of the overflights, the reflectance of the calibration target was measured with a field spectrometer. In addition, the atmospheric optical depths and water vapor abundance were measured from a radiometer station adjacent to the calibration target. These in-situ measurements were used to constrain the MODTRAN radiative transfer code to model the upwelling spectral radiance incident to the sensor aperture during the overflights. Analyses of this modeled radiance in conjunction with the laboratory-calibrated radiance were used to determine the spectral and radiometric calibration of AVIRIS while in flight.

Green, Robert O.↗

Empirical relationships among atmospheric variables from rawinsonde and field data as surrogates for AVIRIS measurements: Estimation of regional land surface evapotranspiration

Empirical relationships between variables are ways of securing estimates of quantities difficult to measure by remote sensing methods. The use of empirical functions was explored between: (1) atmospheric column moisture abundance W (gm H2O/cm(sup 2) and surface absolute water vapor density rho(q-bar) (gm H2O/cm(sup 3), with rho density of moist air (gm/cm(sup 3), q-bar specific humidity (gm H2O/gm moist air), and (2) column abundance and surface moisture flux E (gm H2O/(cm(sup 2)sec)) to infer regional evapotranspiration from Airborne Visible/Infrared Imaging Spectrometers (AVIRIS) water vapor mapping data. AVIRIS provides, via analysis of atmospheric water absorption features, estimates of column moisture abundance at very high mapping rate (at approximately 100 km(sup 2)/40 sec) over large areas at 20 m ground resolution.

Conel, James E.↗

AVIRIS Spectrometer Maps Total Water Vapor Column

Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) processes maps of vertical-column abundances of water vapor in atmosphere with good precision and spatial resolution. Maps provide information for meteorology, climatology, and agriculture.

Conel, James E.↗

Determination of the in-flight spectral and radiometric characteristics of the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS)

AVIRIS is a science research imaging spectrometer that measures radiance in 224 channels between 400 to 2450 nm in the electromagnetic spectrum. To determine the inflight spectral and radiometric characteristics of AVIRIS a validation and calibration experiment was performed. Five data sets were acquired over a calibration site on the homogeneous playa of Rogers Dry Lake, California, U.S. Surface reflectance, atmospheric optical depths, and atmospheric water vapor measurements were acquired concurrently with the overflights. These in situ measurements were used to constrain the LOWTRAN 7 radiative transfer code to predict the total spectral radiance incident at the AVIRIS aperture. These predicted radiances and the AVIRIS measured radiances were analyzed to validate the inflight characteristics. Inflight spectral channel positions and response functions over the AVIRIS spectral range were derived. Radiometric calibration coefficients were calculated for each channel as well as radiometric accuracy, intraflight stability, and noise equivalent delta radiance.

Green, Robert O.↗

Preliminary Analysis Of Data From AVIRIS

Report presents preliminary analysis of performance of Airborne Visible/Infrared Imaging Spectrometer (AVIRIS), a scanning instrument producing images at wavelengths from 400 to 2,450 nm. Includes four spectrometers connected by optical fibers to common set of foreoptics. Focuses upon calibration of instrument and determination of reflectance of surface of Earth from its measurements.

Conel, James E.↗

Determination of surface reflectance and estimates of atmospheric optical depth and single scattering albedo from Landsat Thematic Mapper data

Groound-reflectance data on selected targets for calbiration of a Landsat TM image of Wind River Basin, Wyoming, acquired November 21, 1982 were examined. Field-derived calibration relationships together with Landsat radiometric calibration data are used to convert scanner DN values to spectral radiance for the TM bands and (together with a simplified homogeneous atmospheric model) to obtain estimates of single-scattering albedo and optical depth consistent with the derived path radiance and transmission properties of the atmosphere. These estimates are used to study the problems of evaluation of the magnitude of adjacency effects for reference targets, the assumption of isotropic properties, and the aggregate magnitude of multiple reflections between sky and ground. The radiance calibration equations are also used together with preflight measured signal/noise properties of the TM-4 system to estimate the noise-equivalent reflectance recoverable in practice from the system.

Conel, James E.↗

In-flight validation and calibration of the spectral and radiometric characteristics of the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS)

Through an in-flight calibration experiment at Rogers Dry Lake, California on September 20, 1989, the radiometric and spectral properties of AVIRIS were determined. In-flight spectral channel positions and the spectral response function in 10 regions of the AVIRIS spectral range, taking in all four spectrometers, are shown to agree closely with the corresponding parameters measured in the laboratory. The intraflight stability for the Rogers Dry Lake calibration site is better than 2 percent with the exception of the strong atmospheric water absorptions where the measured radiance is close to zero. This experiment has provided both direct generation of an in-flight spectral and radiometric calibration and validation of the laboratory calibration at the reported level accuracy.

Green, Robert O.↗

In-situ atmospheric water-vapor retrieval in support of AVIRIS validation

A comparison is made between two ground-based atmospheric water-vapor measurement techniques, each of which uses data from a solar-pointing radiometer. One technique uses visible wavelength channels to retrieve aerosol loading, surface pressure readings for Rayleigh scattering analyses, and the 0.94 micron channel to extract water vapor from the residual of total versus scattering opacity. The other technique requires only the ratio of channels centered at 0.94 and 0.87 micron. Results are given for the April 13, 1989 AVIRIS in-flight calibration.

Bruegge, Carol J.↗

The spectral emissivity of prairie and pasture grasses at Konza Prairie, Kansas

Field measurements of spectral radiances are used to determine precise values of the spectral emissivity of grass-thatch-soil complexes to facilitate remote temperature determinations. The emissivity variation with wavelength is very small, emissivity is close to unity, and emissivity is fairly constant in terms of emission angle, land practice, and season. The prairie surface is therefore similar to a grey body and a quasiideal emitter, although determinations of the kinetic temperature are required to confirm the results.

Palluconi, Frank↗

Atmospheric water mapping with the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS), Mountain Pass, California

Observations are given of the spatial variation of atmospheric precipitable water using the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) over a desert area in eastern California, derived using a band ratio method and the 940 nm atmospheric water band and 870 nm continuum radiances. The ratios yield total path water from curves of growth supplied by the LOWTRAN 7 atmospheric model. An independent validation of the AVIRIS-derived column abundance at a point is supplied by a spectral hygrometer calibrated with respect to radiosonde observations. Water values conform to topography and fall off with surface elevation. The edge of the water vapor boundary layer defined by topography is thought to have been recovered. The ratio method yields column abundance estimates of good precision and high spatial resolution.

Conel, James E.↗

Determination of in-flight AVIRIS spectral, radiometric, spatial and signal-to-noise characteristics using atmospheric and surface measurements from the vicinity of the rare-earth-bearing carbonatite at Mountain Pass, California

An assessment of the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) performance was made for a flight over Mountain Pass, California, July 30, 1987. The flight data were reduced to reflectance using an empirical algorithm which compensates for solar, atmospheric and instrument factors. AVIRIS data in conjunction with surface and atmospheric measurements acquired concurrently were used to develop an improved spectral calibration. An accurate in-flight radiometric calibration was also performed using the LOWTRAN 7 radiative transfer code together with measured surface reflectance and atmospheric optical depths. A direct comparison with coincident Thematic Mapper imagery of Mountain Pass was used to demonstrate the high spatial resolution and good geometric performance of AVIRIS. The in-flight instrument noise was independently determined with two methods which showed good agreement. A signal-to-noise ratio was calculated using data from a uniform playa. This ratio was scaled to the AVIRIS reference radiance model, which provided a basis for comparison with laboratory and other in-flight signal-to-noise determinations.

Green, Robert O.↗

Comparison of laboratory calibrations of the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) at the beginning and end of the first flight season

Spectral and radiometric calibrations of the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) were performed in the laboratory in June and November, 1987, at the beginning and end of the first flight season. Those calibrations are described along with changes in instrument characteristics that occurred during the flight season as a result of factors such as detachment of the optical fibers to two of the four AVIRIS spectrometers, degradation in the optical alignment of the spectrometers due to thermally-induced and mechanical warpage, and breakage of a thermal blocking filter in one of the spectrometers. These factors caused loss of signal in three spectrometers, loss of spectral resolution in two spectrometers, and added uncertainty in the radiometry of AVIRIS. Results from in-flight assessment of the laboratory calibrations are presented. A discussion is presented of improvements made to the instrument since the end of the first flight season and plans for the future. Improvements include: (1) a new thermal control system for stabilizing spectrometer temperatures, (2) kinematic mounting of the spectrometers to the instrument rack, and (3) new epoxy for attaching the optical fibers inside their mounting tubes.

Vane, Gregg↗