Search NASA⌕ Search

Engineering topics

Conkin, J.

Publications and source records attributed to Conkin, J..

At least 19 records

Venous Gas Emboli and Ambulation at 4.3 PSIA

Ambulation imparts compressive and decompressive forces into the lower body, potentially creating quasi-stable micronuclei that influence the outcome of hypobaric depressurizations.

Conkin, J.↗

Decompression Sickness During Simulated Low Pressure Exposure is Increased with Mild Ambulation Exercise

Musculoskeletal activity accelerates inert gas elimination during oxygen breathing prior to decompression (prebreathe), but may also promote bubble formation (nucleation) and increase the risk of decompression sickness (DCS). The timing, pattern and intensity of musculoskeletal activity are likely critical to the net effect. The NASA Prebreathe Reduction Program (PRP) combined oxygen prebreathe and exercise preceding a 4.3 psia exposure in non-ambulatory subjects (a microgravity analog) to produce two protocols now used by astronauts preparing for extravehicular activity - one employing cycling and non-cycling exercise (CEVIS: 'cycle ergometer vibration isolation system') and one relying on non-cycling exercise only (ISLE: 'in-suit light exercise'). Current efforts investigate whether light exercise normal to 1 G environments increases the risk of DCS over microgravity simulation.

Pollock, N. W.↗

Venous Gas Emboli and Ambulation at 4.3 PSIA (Preliminary)

Ambulation imparts compressive and decompressive forces into the lower body, potentially creating quasi-stable micronuclei that influence the outcome of hypobaric depressurizations. Hypotheses: ambulation before the conclusion of a denitrogenation (prebreathe) protocol at 14.7 pounds per square inch absolute is not sufficient to increase the incidence of venous gas emboli (VGE) at 4.3 pounds per square inch absolute but is sufficient if performed after tissues become supersaturated with nitrogen at 4.3 pounds per square inch absolute.

Conkin, J.↗

Carbon Monoxide Accumulation in the Extravehicular Mobility Unit

Introduction: Life support technology in large closed systems like submarines and space stations catalyzes carbon monoxide (CO) to carbon dioxide, which is easily removed. However, in a small system like the Extravehicular Mobility Unit (EMU), spacesuit, CO from exogenous (contaminated oxygen (O (sub 2) supply) and endogenous (human metabolism) sources will accumulate in the free suit volume. The free volume becomes a sink for CO that is rebreathed by the astronaut. The accumulation through time depends on many variables: the amount absorbed by the astronaut, the amount produced by the astronaut (between 0.28 and 0.34 moles per hour per kilogram)[1], the amount that enters the suit from contaminated O (sub 2), the amount removed through suit leak, the free volume of the suit, and the O (sub 2) partial pressure[2], just to list a few. Contamination of the EMU O (sub 2) supply with no greater than 1 part per million CO was the motivation for empirical measurements from CO pulse oximetry (SpCO) as well as mathematical modeling of the EMU as a rebreather for CO. Methods: We developed a first-order differential mixing equation as well as an iterative method to compute CO accumulation in the EMU. Pre-post measurements of SpCO (Rad-57, Masimo Corporation) from EMU ground training and on-orbit extravehicular activities (EVAs) were collected. Results: Initial modeling without consideration of the astronaut as a sink but only the source of CO showed that after 8 hours breathing 100 percent O (sub 2) with a 10 milliliter per minute (760 millimeters Hg at 21 degrees Centigrade standard) suit leak, an endogenous production rate of 0.23 moles per hour per kilogram for a 70 kilogram person with 42 liters (1.5 cubic feet) free suit volume resulted in a peak CO partial pressure (pCO) of 0.047 millimeters Hg at 4.3 pounds per square inch absolute (222 millimeters Hg). Preliminary results based on a 2008 model[3] with consideration of the astronaut as a sink and source of CO suggests that most of the rebreathed CO stays bound to hemoglobin and myoglobin and; therefore, pCO only increased to 0.002 millimeters Hg in the EMU. Hemoglobin saturation after 8 hours was an insignificant 0.4 percent compared to about 4 percent for cigarette smokers in the general population. This preliminary modeling result supplements 11 pre-post index finger SpCO measurements from EMU ground training (mean 0.5 percent versus 1 percent, probability equal to 0.41 from paired t-test) and 10 on-orbit pre-post EVAs (mean 1.5 percent versus 1.1 percent, probability equal to 0.17 from paired t-test) that showed no consistent increase, at least no increase outside the accuracy of the oximeter (1 percent display resolution with plus or minus 3 percent Standard Deviation). Discussion: Simulations continue, but a preliminary conclusion is that rebreathing endogenous CO accumulating in the EMU is not a serious medical issue during EVA. The absence of CO poisoning signs or symptoms following hundreds of EVAs is also good empirical evidence that corroborates the limited SpCO measurements and preliminary modeling results.

Conkin, J.↗

Ambulation During Periods of Supersaturation Increase Decompression Stress in Spacewalk Simulations

Musculoskeletal activity accelerates inert gas elimination during oxygen breathing prior to decompression (prebreathe), but may also promote bubble formation (nucleation) and increase the risk of decompression sickness (DCS). The timing, pattern and intensity of musculoskeletal activity and the level of tissue supersaturation are likely critical to the net effect. Understanding the relationships is important to evaluate exercise prebreathe protocols and quantify decompression risk in gravity and microgravity environments. The NASA Prebreathe Reduction Program (PRP) combined oxygen prebreathe and exercise preceding a low pressure (4.3 psia; altitude equivalent of 30,300 ft [9,235 m]) simulation exposure of non-ambulatory subjects (a microgravity analog) to produce two protocols now used by astronauts preparing for extravehicular activity. One protocol included both upright cycling and non-cycling exercise (CEVIS: 'cycle ergometer vibration isolation system') and one protocol relied on non-cycling exercise only (ISLE: 'in-suit light exercise'). CEVIS trial data serve as control data for the current study to investigate the influence of ambulation exercise in 1G environments on bubble formation and the subsequent risk of DCS.

Pollock, N. W.↗

Musculoskeletal-induced Nucleation in Altitude Decompression Sickness

Musculoskeletal activity has the potential to both improve and compromise decompression safety. Exercise enhances inert gas elimination during oxygen breathing prior to decompression (prebreathe), but it may also promote bubble nuclei formation (nucleation), which can lead to gas phase separation and bubble growth and increase the risk of decompression sickness (DCS). The timing, pattern and intensity of musculoskeletal activity and the level of tissue supersaturation may be critical to the net effect. There are limited data available to evaluate cost-benefit relationships. Understanding the relationship is important to improve our understanding of the underlying mechanisms of nucleation in exercise prebreathe protocols and to quantify risk in gravity and microgravity environments. Data gathered during NASA's Prebreathe Reduction Program (PRP) studies combined oxygen prebreathe and exercise followed by low pressure (4.3 psi; altitude equivalent of 30,300 ft [9,235 m]) microgravity simulation to produce two protocols used by astronauts preparing for extravehicular activity. Both the Phase II/CEVIS (cycle ergometer vibration isolation system) and ISLE (in-suit light exercise) trials eliminated ambulation to more closely simulate the microgravity environment. The CEVIS results (35 male, 10 female) serve as control data for this NASA/Duke study to investigate the influence of ambulation exercise on bubble formation and the subsequent risk of DCS.

Pollock, N. W.↗

Ambulation Increases Decompression Sickness in Spacewalk Simulations

Musculoskeletal activity has the potential to both improve and compromise decompression safety. Exercise enhances inert gas elimination during oxygen breathing prior to decompression (prebreathe), but it may also promote bubble nuclei formation (nucleation), which can lead to gas phase separation and bubble growth and increase the risk of decompression sickness (DCS). The timing, pattern and intensity of musculoskeletal activity and the level of tissue supersaturation may be critical to the net effect. Understanding the relationships is important to evaluate exercise prebreathe protocols and quantify decompression risk in gravity and microgravity environments. Data gathered during NASA's Prebreathe Reduction Program (PRP) studies combined oxygen prebreathe and exercise followed by low pressure (4.3 psi; altitude equivalent of 30,300 ft [9,235 m]) microgravity simulation to produce two protocols used by astronauts preparing for extravehicular activity. Both the Phase II/CEVIS (cycle ergometer vibration isolation system) and ISLE (in-suit light exercise) trials eliminated ambulation to more closely simulate the microgravity environment. The CEVIS results (35 male, 10 female) serve as control data for this NASA/Duke study to investigate the influence of ambulation exercise on bubble formation and the subsequent risk of DCS. METHODS Four experiments will replicate the CEVIS exercise-enhanced oxygen prebreathe protocol, each with a different exception. The first of these is currently underway. Experiment 1 - Subjects complete controlled ambulation (walking in place with fixed cadence and step height) during both preflight and at 4.3 psi instead of remaining nonambulatory throughout. Experiment 2 - Subjects remain non-ambulatory during the preflight period and ambulatory at 4.3 psi. Experiment 3 - Subjects ambulate during the preflight period and remain non-ambulatory at 4.3 psi. Experiment 4 - The order of heavy and light exercise employed in the CEVIS protocol is reversed, with the light exercise occurring first (subjects remain non-ambulatory throughout). Decompression stress is assessed with non-invasive ultrasound during each of 14 epochs of a 4 hour simulated spacewalk at 4.3 psi; aural Doppler is used to monitor bubbles (Spencer grade 0-IV scale) passing through the pulmonary artery, and two-dimensional echocardiographic imaging is used to look for left ventricular gas emboli (LVGE; the presence of which is a test termination criterion). Venous blood is collected at baseline and twice following repressurization to determine if the decompression stress is correlated with microparticles (cell fragments) accumulation. The plan is to test 25-50 subjects in each experiment. Fisher Exact Tests (one-tailed) are used to compare test and control groups. Trials are suspended when the DCS or grade IV VGE observations reach 70% confidence of DCS risk >15% and grade IV VGE risk >20%. RESULTS Experiment 1 was concluded with 20 complete trials (15 male, 5 female) since the statistical outcome would not change with five additional trials. The observed DCS was significantly greater in Experiment 1 than in CEVIS trials (4/20 [20%] vs. 0/45 [0%], respectively, p=0.007), as was the frequency of peak grade IV VGE (6/21 [29%; including one additional subject that presented grade IV VGE but whose trial was ended before completion when LVGE were observed] vs. 3/45 [7%], respectively, p=0.024). Experiment 3 trials are now underway, with 11 trials completed (10 male, 1 female). Preliminary results indicate no difference in observed DCS between Experiment 3 and CEVIS trials (1/11 [9%] vs. 0/45 [0%], respectively, p=0.196), or between Experiment 3 and Experiment 1 trials (p=0.405). The frequency of peak grade IV VGE in Experiment 3 (2/11 [18%]) did not differ from CEVIS or Experiment 1 trials (p=0.251 and p=0.425, respectively). Microparticle patterns are widely variable and still under analysis. DISCUSSION The results of the Experiment 1 trials support the thesis that decompression stress is increased by ambulation exercise, given the higher incidence of DCS and grade IV VGE when compared to the non-ambulatory PRP CEVIS trials. Experiment 3 trials are incomplete, but suggest that the effect of ambulation during ground level preflight oxygen breathing alone, when subjects are undersaturated with inert gas, may not differ in risk from ambulation at both preflight and spacesuit pressures, the latter when subjects are supersaturated with inert gas. Further trials are needed to confirm the relative effects of ambulation in undersaturated vs. supersaturated states and to determine whether light exercise facilitates the removal of heavy exercise-induced nucleation (Experiment 4).

Pollock, N. W.↗

Towards Probablistic Assessment of Hypobaric Decompression Sickness Treatment

INTRODUCTION: Pressure, oxygen (O2), and time are the pillars to effective treatment of decompression sickness (DCS). The NASA DCS Treatment Model links a decrease in computed bubble volume to the resolution of a symptom. The decrease in volume is realized in two stages: a) during the Boyle's Law compression and b) during subsequent dissolution of the gas phase by the O2 window. METHODS: The cumulative distribution of 154 symptoms that resolved during repressurization was described with a log-logistic density function of pressure difference (deltaP as psid) associated with symptom resolution and two other explanatory variables. The 154 symptoms originated from 119 cases of DCS during 969 exposures in 47 different altitude tests. RESULTS: The probability of symptom resolution [P(symptom resolution)] = 1 / (1+exp(- (ln(deltaP) - 1.682 + 1.089×AMB - 0.00395×SYMPTOM TIME) / 0.633)), where AMB is 1 when the subject ambulated as part of the altitude exposure or else 0 and SYMPTOM TIME is the elapsed time in min from start of the altitude exposure to recognition of a DCS symptom. The P(symptom resolution) was estimated from computed deltaP from the Tissue Bubble Dynamics Model based on the "effective" Boyle's Law change: P2 - P1 (deltaP, psid) = P1×V1/V2 - P1, where V1 is the computed volume of a spherical bubble in a unit volume of tissue at low pressure P1 and V2 is computed volume after a change to a higher pressure P2. V2 continues to decrease through time at P2, at a faster rate if 100% ground level O2 was breathed. The computed deltaP is the effective treatment pressure at any point in time as if the entire deltaP was just from Boyle's Law compression. DISCUSSION: Given the low probability of DCS during extravehicular activity and the prompt treatment of a symptom with options through the model it is likely that the symptom and gas phase will resolve with minimum resources and minimal impact on astronaut health, safety, and productivity.

Conkin, J.↗

Approximate Simulation of Acute Hypobaric Hypoxia with Normobaric Hypoxia

INTRODUCTION. Some manufacturers of reduced oxygen (O2) breathing devices claim a comparable hypobaric hypoxia (HH) training experience by providing F(sub I) O2 < 0.209 at or near sea level pressure to match the ambient O2 partial pressure (iso-pO2) of the target altitude. METHODS. Literature from investigators and manufacturers indicate that these devices may not properly account for the 47 mmHg of water vapor partial pressure that reduces the inspired partial pressure of O2 (P(sub I) O2). Nor do they account for the complex reality of alveolar gas composition as defined by the Alveolar Gas Equation. In essence, by providing iso-pO2 conditions for normobaric hypoxia (NH) as for HH exposures the devices ignore P(sub A)O2 and P(sub A)CO2 as more direct agents to induce signs and symptoms of hypoxia during acute training exposures. RESULTS. There is not a sufficient integrated physiological understanding of the determinants of P(sub A)O2 and P(sub A)CO2 under acute NH and HH given the same hypoxic pO2 to claim a device that provides isohypoxia. Isohypoxia is defined as the same distribution of hypoxia signs and symptoms under any circumstances of equivalent hypoxic dose, and hypoxic pO2 is an incomplete hypoxic dose. Some devices that claim an equivalent HH experience under NH conditions significantly overestimate the HH condition, especially when simulating altitudes above 10,000 feet (3,048 m). CONCLUSIONS. At best, the claim should be that the devices provide an approximate HH experience since they only duplicate the ambient pO2 at sea level as at altitude (iso-pO2 machines). An approach to reduce the overestimation is to at least provide machines that create the same P(sub I)O2 (iso-P(sub I)O2 machines) conditions at sea level as at the target altitude, a simple software upgrade.

Conkin, J.↗

Decompression Sickness After Air Break in Prebreathe Described with a Survival Model

Data from Brooks City-Base show the decompression sickness (DCS) and venous gas emboli (VGE) consequences of air breaks in a resting 100% O2 prebreathe (PB) prior to a hypobaric exposure. METHODS: DCS and VGE survival times from 95 controls for a 60 min PB prior to 2-hr or 4-hr exposures to 4.37 psia are statistically compared to 3 break in PB conditions: a 10 min (n=40), 20 min (n=40), or 60 min break (n=32) 30 min into the PB followed by 30 min of PB. Ascent rate was 1,524 meters / min and all exposures included light exercise and 4 min of VGE monitoring of heart chambers at 16 min intervals. DCS survival time for combined control and air breaks were described with an accelerated log logistic model where exponential N2 washin during air break was described with a 10 min half-time and washout during PB with a 60 min half-time. RESULTS: There was no difference in VGE or DCS survival times among 3 different air breaks, or when air breaks were compared to control VGE times. However, 10, 20, and 60 min air breaks had significantly earlier survival times compared to control DCS times, certainly early in the exposures. CONCLUSION: Air breaks of 10, 20, and 60 min after 30 min of a 60 min PB reduced DCS survival time. The survival model combined discrete comparisons into a global description mechanistically linked to asymmetrical N2 washin and washout kinetics based on inspired pN2. Our unvalidated regression is used to compute additional PB time needed to compensate for an air break in PB within the range of tested conditions.

Conkin, J.↗

Description of the NASA Hypobaric Decompression Sickness Database (1982-1998)

The availability of high-speed computers, data analysis software, and internet communication are compelling reasons to describe and make available computer databases from many disciplines. Methods: Human research using hypobaric chambers to understand and then prevent decompression sickness (DCS) during space walks has been conducted at the Johnson Space Center (JSC) from 1982 to 1998. The data are archived in the NASA Hypobaric Decompression Sickness Database, within an Access 2003 Relational Database. Results: There are 548 records from 237 individuals that participated in 31 unique tests. Each record includes physical characteristics, the denitrogenation procedure that was tested, and the outcome of the test, such as the report of a DCS symptom and the intensity of venous gas emboli (VGE) detected with an ultrasound Doppler bubble detector as they travel in the venous blood along the pulmonary artery on the way to the lungs. We documented 84 cases of DCS and 226 cases where VGE were detected. The test altitudes were 10.2, 10.1, 6.5, 6.0, and 4.3 pounds per square inch absolute (psia). 346 records are from tests conducted at 4.3 psia, the operating pressure of the current U.S. space suit. 169 records evaluate the Staged 10.2 psia Decompression Protocol used by the Space Shuttle Program. The mean exposure time at altitude was 242.3 minutes (SD = 80.6), with a range from 120 to 360 minutes. Among our test subjects, 96 records of exposures are females. The mean age of all test subjects was 31.8 years (SD = 7.17), with a range from 20 to 54 years. Discussion: These data combined with other published databases and evaluated with metaanalysis techniques would extend our understanding about DCS. A better understanding about the cause and prevention of DCS would benefit astronauts, aviators, and divers.

Wessel, J. H., III↗

Exploiting Aerobic Fitness to Reduce Risk of Hypobaric Decompression Sickness

Decompression sickness (DCS) is multivariable. But we hypothesize an aerobically fit person is less likely to experience hypobaric DCS than an unfit person given that fitness is exploited as part of the denitrogenation (prebreathe, PB) process prior to an altitude exposure. Aerobic fitness is peak oxygen uptake (VO2pk, ml/kg/min). Treadmill or cycle protocols were used over 15 years to determine VO2pks. We evaluated dichotomous DCS outcome and venous gas emboli (VGE) outcome detected in the pulmonary artery with Doppler ultrasound associated with VO2pk for two classes of experiments: 1) those with no PB or PB under resting conditions prior to ascent in an altitude chamber, and 2) PB that included exercise for some part of the PB. There were 165 exposures (mean VO2pk 40.5 plus or minus 7.6 SD) with 25 cases of DCS in the first protocol class and 172 exposures (mean VO2pk 41.4 plus or minus 7.2 SD) with 25 cases of DCS in the second. Similar incidence of the DCS (15.2% vs. 14.5%) and VGE (45.5% vs. 44.8%) between the two classes indicates that decompression stress was similar. The strength of association between outcome and VO2pk was evaluated using univariate logistic regression. An inverse relationship between the DCS outcome and VO2pk was evident, but the relationship was strongest when exercise was done as part of the PB (exercise PB, coef. = -0.058, p = 0.07; rest or no PB, coef. = -0.005, p = 0.86). There was no relationship between VGE outcome and VO2pk (exercise PB, coef. = -0.003, p = 0.89; rest or no PB, coef. = 0.014, p = 0.50). A significant change in probability of DCS was associated with fitness only when exercise was included in the denitrogenation process. We believe a fit person that exercises during PB efficiently eliminates dissolved nitrogen from tissues.

Conkin, J.↗

Late Rather Than Early Onset Bubbles in the Pulmonary Artery During Altitude Exposures Correlate Better with the Onset of "Pain-Only" Decompression Illness

Mechanistic insight about "pain-only" decompression illness (DCI) is limited given indirect information about venous gas emboli (VGE) detected in the pulmonary artery with Doppler ultrasound. However, we show that VGE first detected late in an altitude exposure are closely associated with subsequent symptom onset. Knowing that VGE occur late is an indication that a symptom will occur soon, but this is not a sufficient condition to guarantee that a symptom will occur.

Conkin, J.↗

Field Evaluation in Four NEEMO Divers of a Prototype In-suit Doppler Ultrasound Bubble Detector

It is desirable to know if astronauts produce venous gas emboli (VGE) as a result of their exposure to 4.3 psia during space walks. The current prototype in-suit Doppler (ISD) ultrasound bubble detector provides an objective assessment of decompression stress by monitoring for VGE. The NOAA Aquarius habitat and NASA Extreme Environment Mission Operations (NEEMO) series of dives provided an opportunity to assess the ability of the prototype ISDs to record venous blood flow and possibly detect VGE in the pulmonary artery. From July 16 to 29,2003, four aquanauts (two males and two females) donned the ISD for a 4 hr automated recording session, following excursion dives (up to 6hrs and 29 MSW below storage depth) from air saturation at 17 MSW. Doppler recordings for 32 excursion dives were collected. The recordings consisted of approximately 150 digital wave files. Each wave file contained 24 sec of recording for each min. A 1 - 4 Doppler Quality Score (DQS) was assigned to each wave file in 17 of the 32 records evaluated to date. A DQS of 1 indicates a poor flow signal and a score of 4 indicates an optimum signal. Only 23% of all wave files had DQSs considered adequate to detect low grade VGE (Spencer I-II). The distribution of DQS in 2,356 wave files is as follows: DQS 1-56%, DQS 2-21%, DQS 3-18% and DQS 4-5%. Six of the 17 records had false positive VGE (Spencer I-IV) detected in one or more wave files per dive record. The false positive VGE recordings are attributable to air entrainment associated with drinking (verified by control tests), and this observation is important as astronauts drink water during space walks. The current ISD design provides quality recordings only over a narrow range of chest anatomy.

Acock, K. E.↗

The Decompression Sickness and Venous Gas Emboli Consequences of Air Breaks During 100% Oxygen Prebreathe

Not enough is known about the increased risk of hypobaric decompression sickness (DCS) and production of venous (VGE) and arterial (AGE) gas emboli following an air break in an otherwise normal 100% resting oxygen (O2) prebreathe (PB), and certainly a break in PB when exercise is used to accelerate nitrogen (N2) elimination from the tissues. Current Aeromedical Flight Rules at the Johnson Space Center about additional PB payback times are untested, possibly too conservative, and therefore not optimized for operational use. A 10 min air break at 90 min into a 120 min PB that includes initial dual-cycle ergometry for 10 min will show a measurable increase in the risk of DCS and VGE after ascent to 4.3 psia compared to a 10 min break at 15 min into the PB, or when there is no break in PB. Data collection with humans begins in 2005, but here we first evaluate the hypothesis using three models of tissue N2 kinetics: Model I is a simple single half-time compartment exponential model, Model II is a three compartment half-time exponential model, and Model III is a variable half-time compartment model where the percentage of maximum O2 consumption for the subject during dual-cycle ergometry exercise defines the half-time compartment. Model I with large rate constants to simulate an exercise effect always showed a late break in PB had the greatest consequence. Model II showed an early break had the greatest consequence. Model III showed there was no difference between early or late break in exercise PB. Only one of these outcomes will be observed when humans are tested. Our results will favor one of these models, and so advance our understanding of tissue N2 kinetics, and of altitude DCS after an air break in PB.

Conkin, J.↗

Operational Implementation of a 2-Hour Prebreathe Protocol for International Space Station

Procedures, equipment, and analytical techniques were developed to implement the ground tested 2-hour protocol in-flight operations. The methods are: 1) The flight protocol incorporates additional safety margin over the ground tested protocol. This includes up to 20 min of additional time on enriched O2 during suit purge and pressure check, increased duration of extravehicular activity (EVA) preparation exercise during O2 prebreathing (up to 90 min vs; the tested 24 min), and reduced rates of depressurization. The ground test observations were combined with model projections of the conservative measures (using statistical models from Duke University and NASA JSQ to bound the risk of Type I and Type II decompression sickness (DCS). 2) An inflight exercise device using the in-flight ergometer and elastic tubes for upper body exercise was developed to replicate the dual cycle exercise in the ground trials. 3) A new in-flight breathing system was developed and man-tested. 4) A process to monitor inflight experience with the protocol, including the use of an in-suit Doppler bubble monitor when available, was developed. The results are: 1) The model projections of the conservative factors of the operational protocol were shown to reduce the risk of DCS to levels consistent with the observations of no DCS to date in the shuttle program. 2) Cross over trials of the dual cycle ergometer used in ground tests and the in-flight exercise system verified that02consumption and the % division of work between upper and lower body was not significantly different at the p= 0.05 level. 3) The in-flight breathing system was demonstrated to support work rates generating 75% O2(max) in 95 percentile subjects. 4) An in-flight monitoring plan with acceptance criteria was put in place for the 2-hour prebreathe protocol. And the conclusions are: The 2-hour protocol has been approved for flight, and all implementation efforts are in place to allow use of the protocol as early as flight ISS 7A, now scheduled in November of 2000.

Waligora, James M.↗