Search NASA⌕ Search

Engineering topics

Conradi, Mark S.

Publications and source records attributed to Conradi, Mark S..

Bioenergy sorghum stem growth regulation: intercalary meristem localization, development, and gene regulatory network analysis

SUMMARY Bioenergy sorghum is a highly productive drought tolerant C 4 grass that accumulates 80% of its harvestable biomass in approximately 4 m length stems. Stem internode growth is regulated by development, shading, and hormones that modulate cell proliferation in intercalary meristems (IMs). In this study, sorghum stem IMs were localized above the pulvinus at the base of elongating internodes using magnetic resonance imaging, microscopy, and transcriptome analysis. A change in cell morphology/organization occurred at the junction between the pulvinus and internode where LATERAL ORGAN BOUNDARIES ( SbLOB ), a boundary layer gene, was expressed. Inactivation of an AGCVIII kinase in DDYM ( dw2 ) resulted in decreased SbLOB expression, disrupted IM localization, and reduced internode cell proliferation. Transcriptome analysis identified approximately 1000 genes involved in cell proliferation, hormone signaling, and other functions selectively upregulated in the IM compared with a non‐meristematic stem tissue. This cohort of genes is expressed in apical dome stem tissues before localization of the IM at the base of elongating internodes. Gene regulatory network analysis identified connections between genes involved in hormone signaling and cell proliferation. The results indicate that gibberellic acid induces accumulation of growth regulatory factors (GRFs) known to interact with ANGUSTIFOLIA (SbAN3), a master regulator of cell proliferation. GRF:AN3 was predicted to induce SbARF3/ETT expression and regulate SbAN3 expression in an auxin‐dependent manner. GRFs and ARFs regulate genes involved in cytokinin and brassinosteroid signaling and cell proliferation. The results provide a molecular framework for understanding how hormone signaling regulates the expression of genes involved in cell proliferation in the stem IM.

59 BASIC BIOLOGICAL SCIENCES↗

Simple through-plane spatial filter for 2D MRI projections

A simple spatial filter for 2D projection MR imaging is introduced. It works in the third (unresolved) direction to eliminate uniform or slowly varying interfering background signals. A constant amplitude gradient pulse in the unresolved direction is applied at the same time as the usual phase encode gradient during 2D acquisition. The filter is demonstrated for root imaging in soil, where background soil water signals can be troublesome. The filter suppresses the soil water signal while preserving the desired signal of plant roots. Fundamental to the operation of the filter is that the roots are sparse in the image domain, meaning there are relatively few pixels with multiple roots present. Here, the performance of the through-plane filter is demonstrated and compares favorably to more conventional in-plane spatial filtering.

47 OTHER INSTRUMENTATION↗

Design and demonstration of a low‐field magnetic resonance imaging rhizotron for in‐field imaging of energy sorghum roots

Abstract Root phenotyping provides critical information to plant breeders for developing varieties with improved drought tolerance, greater root biomass, and greater nutrient use efficiency. Phenotyping roots in the natural environment is important for understanding the effect of the soil environment on root genotypic expressions. The goal of this work was to design and test a field‐scale mobile low‐field magnetic resonance imaging (LF‐MRI) Rhizotron that produces actionable root phenotyping data. We demonstrated this novel technology for root visualization and quantification using a LF‐MRI Rhizotron operating at 47 mT with two soil types. The LF‐MRI Rhizotron weights 453 kg, with a height of 90 cm, a diameter of 28 cm and an imaging field of view of 28 cm × 28 cm. The unit was operated in a Belk clay (Entic Hapluderts) and Weswood silt loam (Udifluventic Halustepts) generating 2‐D and 3‐D image data sets. The 2‐D image data had a collection time of 16.5 min per image at an image resolution of 2.2 mm per pixel. The 3‐D data had a collection time of 13 h per image with a 2.2 × 2.2 × 2.2 mm voxel resolution. Low‐field magnetic resonance imaging worked well for visualizing roots in moderate to high clay soils, demonstrating the potential for this technology; however, the broad application of this platform is hampered due to the prohibitively long scanning time to obtain 3‐D images. By increasing the field strength, and therefore the signal‐to‐noise ratio, faster scan times can enable a more useful system for root phenotyping.

Bagnall, G. Cody↗

Probe for operando in situ electrochemical nuclear magnetic resonance spectroscopy

Electrochemical devices with metal casings have been considered incompatible with nuclear magnetic resonance (NMR) spectroscopy because the oscillating magnetic fields (“rf fields”) responsible for excitation and detection of NMR active nuclei do not penetrate metals. According to the present invention, rf fields can still efficiently penetrate into nonmetallic layers of electrochemical cells (such as a coin cell battery configuration) provided the magnetic field is oriented tangentially to the electrochemical cell electrodes in a “skimming” orientation. As an example, noninvasive high field in situ 7Li and 19F NMR of an unmodified commercial off-the-shelf rechargeable coin cell was demonstrated using a traditional external NMR coil setup. The in operando NMR measurements revealed that irreversible physical changes accumulate at the anode during electrochemical cycling.

Sorte, Eric Glenn↗

Low-cost gradient amplifiers for small MRI systems

Here, we describe low-cost gradient amplifiers for small MRI systems, such as those based on small/medium permanent magnets. The requirements for MRI gradient amplifiers are quite similar to those of modestly priced audio stereo power amplifiers. Such amplifiers for sound service can be modified to be DC coupled, extending their response down to zero frequency, as needed for MRI gradient service. We describe such modifications to one unit (Samson Servo 600) and mention a commercially available modification of another. The 600 is capable of an output greater than ±8 A and ±60 V, much greater than our needs for a greenhouse MRI. Audio amplifiers can be used this way as controlled voltage (CV) gradient amplifiers, with acceptable performance because the gradient coils typically have short L/R time constants. Superior performance can be had by using a controlled current (CC) “front end”; the circuit of our simple front end is included. The complete 3-axis CC system costs about $1200.

47 OTHER INSTRUMENTATION↗

NMR spectroscopy of coin cell batteries with metal casings

Battery cells with metal casings are commonly considered incompatible with nuclear magnetic resonance (NMR) spectroscopy because the oscillating radio-frequency magnetic fields (“rf fields”) responsible for excitation and detection of NMR active nuclei do not penetrate metals. Here, we show that rf fields can still efficiently penetrate nonmetallic layers of coin cells with metal casings provided “B 1 damming” configurations are avoided. With this understanding, we demonstrate noninvasive high-field in situ 7 Li and 19 F NMR of coin cells with metal casings using a traditional external NMR coil. This includes the first NMR measurements of an unmodified commercial off-the-shelf rechargeable battery in operando, from which we detect, resolve, and separate 7 Li NMR signals from elemental Li, anodic β-LiAl, and cathodic Li x MnO 2 compounds. Real-time changes of β-LiAl lithium diffusion rates and variable β-LiAl 7 Li NMR Knight shifts are observed and tied to electrochemically driven changes of the β-LiAl defect structure.

25 ENERGY STORAGE↗

Precision current regulator for NMR electromagnets

When using electromagnets or non-persistent superconducting magnets, the field stability can be directly proportional to the current stability. We present in this report a simple design for a current regulator based upon a high-precision, dc-dc fluxgate transformer. The output current and NMR frequency are stabilized by about a factor of 50, over times of order one hour. The method can be applied to essentially any current supply.

59 BASIC BIOLOGICAL SCIENCES↗

Revisiting Anisotropic Diffusion of Carbon Dioxide in the Metal–Organic Framework Zn 2 (dobpdc)

The diffusion of gases confined in nanoporous materials underpins membrane and adsorption-based gas separations, yet relatively few measurements of diffusion coefficients in the promising class of materials, metal–organic frameworks (MOFs), have been reported to date. Recently we reported self-diffusion coefficients for 13 CO 2 in the MOF Zn 2 (dobpdc) (dobpdc 4– = 4,4'-dioxidobiphenyl-3,3'-dicarboxylate) which has one-dimensional channels with a diameter of approximately 2 nm [Forse, A. C.; J. Am. Chem. Soc. 2018, 140, 1663-1673]. By analyzing the evolution of the residual 13 C chemical shift anisotropy line shape at different gradient strengths, we obtained self-diffusion coefficients both along (D ∥ ) and between (D ⊥ ) the one-dimensional MOF channels. The observation of nonzero D ⊥ was unexpected based on the single crystal X-ray diffraction structure and flexible lattice molecular dynamics simulations, and we proposed that structural defects may be responsible for self-diffusion between the MOF channels. In this paper we revisit this analysis and show that homogeneous line broadening must be taken into account to obtain accurate values for D ⊥ . In the presence of homogeneous line broadening, intensity at a particular NMR frequency represents signal from crystals with a range of orientations relative to the applied magnetic field and magnetic gradient field. To quantify these effects, we perform spectral simulations that take into account homogeneous broadening and allow improved D ⊥ values to be obtained. Finally, our new analysis best supports nonzero D ⊥ at all studied dosing pressures and shows that our previous analysis overestimated D ⊥ .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Anomalous H 2 Desorption Rate of NaAlH 4 Confined in Nitrogen-Doped Nanoporous Carbon Frameworks

Confining NaAlH 4 in nanoporous carbon scaffolds is known to alter the sorption kinetics and/or pathways of the characteristic bulk hydride reactions through interaction with the framework at the interface, increased specific surface area of the resulting nanoparticles, decreased hydrogen diffusion distances, and prevention of phase segregation. Although the nanosize effects have been well studied, the influence of the carbon scaffold surface chemistry remains unclear. Here we compare the hydrogen sorption characteristics of NaAlH 4 confined by melt infiltration in nitrogen-doped/undoped ordered nanoporous carbon of two different geometries. 23 Na and 27 Al MAS NMR, N 2 sorption, and PXRD verify NaAlH 4 was successfully confined and remains intact in the carbon nanopores after infiltration. Both the N-doped/undoped nanoconfined systems demonstrate improved reversibility in relation to the bulk hydride during hydrogen desorption/absorption cycling. Isothermal kinetic measurements indicate a lowering of the activation energy for H 2 desorption by as much as 70 kJ/mol in N-doped frameworks, far larger than the reduction in carbon-only frameworks. Most interestingly, this dramatic lowering of the activation energy is accompanied by an unexpected and anomalously low NaAlH 4 desorption rate in the N-doped frameworks. This suggests that the framework surface chemistry plays an important role in the desorption process and that the rate limiting step for desorption may be associated with interactions of the hydride and host surface. Our results indicate that functionalization of carbon scaffold surface chemistry with heteroatoms provides a powerful method of altering the characteristic hydrogen sorption properties of confined metal hydride systems. Furthermore, this technique may prove beneficial in the path to a viable metal hydride-based hydrogen storage system.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

CO 2 Adsorption on PIMs Studied with 13 C NMR Spectroscopy

Polymers of intrinsic microporosity (PIMs) can be functionalized with nitrogen-bearing groups, such as a nitrile group for PIM-1 and a methylated tetrazole group for MTZ-PIM, to physisorb CO 2 . Static 13 C NMR spectroscopy was used to explore CO 2 dynamics by analysis of one-dimensional spectra and T 2 relaxation times at temperatures ranging from 6 to 295 K. Each polymer had two different loadings of CO 2 to confirm the dominating relaxation mechanism at lower temperatures and deduce the identity of the weaker secondary adsorption site on the rigid polymer backbone. Both polymers, with a high loading of CO 2 , experience a narrowing of the 13 C NMR line width as the samples are warmed to 80 K, which is the onset of the weakly adsorbed CO 2 hopping on and off the polymer backbone.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A flow-through, elevated-temperature and -pressure NMR apparatus for in-situ CO 2 sequestration studies

Here we report an apparatus for in-situ nuclear magnetic resonance (NMR) studies of chemical reactions of dissolved 13 CO 2 with minerals (rock or powder) under continuous flow. The operating range of the apparatus is 18–150 °C and 1–140 bar. A flow pump is used to circulate a CO 2 -water solution, with a heated mixing vessel where CO 2 gas equilibrates with a water solution. The NMR probe is built around a strong zirconia ceramic vessel, with o-ring sealed connections; the mineral is contained inside. The horizontal orientation of the zirconia vessels allows use of a radio frequency (rf) solenoid for improved spin sensitivity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Search for Effects of an Electrostatic Potential on Clocks in the Frame of Reference of a Charged Particle

Results of experiments to confirm a theory that links classical electromagnetism with the geometry of spacetime are described. The theory, based on the introduction of a Torsion tensor into Einstein s equations and following the approach of Schroedinger, predicts effects on clocks attached to charged particles, subject to intense electric fields, analogous to the effects on clocks in a gravitational field. We show that in order to interpret this theory, one must re-interpret all clock changes, both gravitational and electromagnetic, as arising from changes in potential energy and not merely potential. The clock is provided naturally by proton spins in hydrogen atoms subject to Nuclear Magnetic Resonance trials. No frequency change of clocks was observed to a resolution of 6310(exp -9). A new "Clock Principle" was postulated to explain the null result. There are two possible implications of the experiments: (a) The Clock Principle is invalid and, in fact, no metric theory incorporating electromagnetism is possible; (b) The Clock Principle is valid and it follows that a negative rest mass cannot exist.

Ringermacher, Harry I.↗

Search For Effects of an Electrostatic Potential on Clocks in the Frame of Reference of a Charged Particle

The Program Planning meeting was held on Jan 27-28 at the Washington University, Dept. of Physics. Experiment strategies and details were discussed and milestones mapped. Dr. Ringermacher, the program technical leader and Co-Principal Investigator, presented a Physics Department seminar on the theory and experiment in progress. Following the meeting Professor Conradi (CO-PI) and his students designed the NMR probe and electronics required for the experiment and submitted the drawings to the shop for fabrication. Dr. Cassenti, at UTRC, initiated analytic and computer analysis of the experimental conditions in order to anticipate possible classical effects. Dr. Ringermacher, at KRONOTRAN, re-evaluated the experiment interpretation from the theory and continued working to secure its underpinnings.

Ringermacher, Harry I.↗