Search NASA⌕ Search

Engineering topics

Conway, Z.

Publications and source records attributed to Conway, Z..

The EIC accelerator: design highlights and project status

The design of the electron-ion collider (EIC) at Brookhaven National Laboratory is well underway, aiming at a peak electron-proton luminosity of 10e+34 cm^-1·sec^-1. This high luminosity, the wide center-of-mass energy range from 29 to 141 GeV (e-p) and the high level of polarization require innovative solutions to maximize the performance of the machine, which makes the EIC one of the most challenging accelerator projects to date. The complexity of the EIC will be discussed, and the project status and plans will be presented.

43 PARTICLE ACCELERATORS↗

Design and Prototyping of the Electron Ion Collider Electron Storage Ring 591 MHz Elliptical SRF Cavity

The Electron Ion Collider (EIC) is a new nuclear phys-ics research facility to be constructed at Brookhaven Lab (BNL). It consists a few accelerator complexes, each re-quires some different SRF and RF systems. Among them, the electron storage ring?s (ESR) 591 MHz fundamental RF system is one of the most challenging. This 17 cavi-ties system will handle a variable beam current of up to 2.5 A, and replenish up to 10 MW of beam power losses from both synchrotron radiation (SR) and high-order modes (HOM). In this paper, we will report the progress and findings of the ongoing design and prototyping of this cavity.

Guo, J.↗

The mapping & avoidance of high order cavity modes

In this paper a technique developed in 2016 is presented for mapping the multidimensional, multi-mode high order mode landscape of a beam driven super conducting RF cavity. The initial use case for this technique was intended to allow longitudinal gradient control of a beam driven super conducting cavity while simultaneously avoiding many dangerous high order modes and excessive component stresses. This paper will focus on the stability and component stress considerations of the 56MHz superconducting cavity, located in the 4 o’clock sector interaction region of the Relativistic Heavy Ion Collider (RHIC) at Brookhaven National Laboratory. The 56MHz cavity is intended to work in conjunction with the Stochastic Cooling system to improve the longitudinal confinement in the central 197MHz RF bucket and thus increase the integrated luminosity during heavy ion beam runs at RHIC.

43 PARTICLE ACCELERATORS↗

Electron-Ion Collider Design Status

The Electron-Ion Collider (EIC) is being designed for construction at Brookhaven National Laboratory. Activities have been focused on beam-beam simulations, polarization studies, and beam dynamics, as well as on maturing the layout and lattice design of the constituent accelerators and the interaction region. The latest design advances will be presented.

43 PARTICLE ACCELERATORS↗

High power coupler development for EIC

The synchrotron radiation loss in EIC Electron Storage Ring is as high as up to 10 MW. This energy loss will be compensated by 17 2K 591 MHz single-cell SRF cavities with a combined total of 34 high power fundamental power couplers. Each power coupler will operate 92% of revolution time CW and ~8% of revolution time with 400 kW forward power due to the beam abort gap. To satisfy the EIC needs, we developed two 500 kW standing-wave FPC designs at BNL based on either a BeO and an Al 2 O 3 RF window. This paper will briefly summarize test results of the BeO window FPC , and describe the design development of the Al 2 O 3 window based FPC.

43 PARTICLE ACCELERATORS↗

HIGH POWER COUPLER DEVELOPMENT FOR EIC

The synchrotron radiation loss in EIC Electron Storage Ring is as high as up to 10 MW. This energy loss will be compensated by 17 2K 591 MHz single-cell SRF cavities with a combined total of 34 high power fundamental power couplers. Each power coupler will operate 92% of revolution time CW and ~8% of revolution time with 400 kW forward power due to the beam abort gap. To satisfy the EIC needs, we developed two 500 kW standing-wave FPC designs at BNL based on either a BeO and an Al2O3 RF window. This paper will briefly summarize test results of the BeO window FPC, and describe the design development of the Al2O3 window based FPC.

43 PARTICLE ACCELERATORS↗

Design of the Multi-Ion Injector Linac for the JLAB EIC (JLEIC)

An Electron Ion Collider (EIC) is the highest priority for future U.S. accelerator-based nuclear physics facility following the completion of the Facility for Rare Isotope Beams (FRIB). Two laboratories are competing to host the future EIC: Brookhaven National Lab. (BNL) and Jefferson Lab. (JLab). The baseline design of JLab's Electron Ion Collider (JLEIC) ion complex comprises a pulsed superconducting (SC) linac injector capable of accelerating all ions from protons to lead, where proton and light ion beams can be polarized. After reviewing the design requirements for the injector linac, important design choices such as the room-temperature (RT) section design, the transition energy between the RT and SC sections and the stripping energy for heavy ions will be discussed. The design of the different linac sections will be presented as well as the results of end-to-end beam dynamics simulations for polarized deuterons and unpolarized lead ions.

Mustapha, B.↗

PRELIMINARY TEST RESULTS OF A PROTOTYPE FAST KICKER FOR APS MBA UPGRADE

The APS multi-bend achromatic (MBA) upgrade storage ring plans to support two bunch fill patterns: a 48-bunch and a 324-bunch. A “swap out” injection scheme is required. In order to provide the required kick to injected beam, to minimize the beam loss and residual oscillation of injected beam, and to minimize the perturbation to stored beam during injection, the rise, fall, and flat-top parts of the kicker pulse must be within a 16.9-ns interval. Stripline-type kickers are chosen for both injection and extraction. We developed a prototype kicker that supports a ±15kV differential pulse voltage. We performed high voltage discharge, TDR measurement, high voltage pulse test and beam test of the kicker. We report the final design of the fast kicker and the test results.

APS MBA UPGRADE↗

The PIP-II Conceptual Design Report

The Proton Improvement Plan-II (PIP-II) encompasses a set of upgrades and improvements to the Fermilab accelerator complex aimed at supporting a world-leading neutrino program over the next several decades. PIP-II is an integral part of the strategic plan for U.S. High Energy Physics as described in the Particle Physics Project Prioritization Panel (P5) report of May 2014 and formalized through the Mission Need Statement approved in November 2015. As an immediate goal, PIP-II is focused on upgrades to the Fermilab accelerator complex capable of providing proton beam power in excess of 1 MW on target at the initiation of the Long Baseline Neutrino Facility/Deep Underground Neutrino Experiment (LBNF/DUNE) program, currently anticipated for the mid- 2020s. PIP-II is a part of a longer-term goal of establishing a high-intensity proton facility that is unique within the world, ultimately leading to multi-MW capabilities at Fermilab....

43 PARTICLE ACCELERATORS↗

Low-Level RF Control of Microphonics in Superconducting Spoke-Loaded Cavities

This paper presents the results of cw RF frequency control and RF phase-stabilization experiments performed with a piezoelectric fast tuner mechanically coupled to a superconducting, 345 MHz, ? = 0.5 triple-spoke-loaded cavity operating at 4.2K. The piezoelectric fast tuner damped low-frequency microphonic-noise by an order of magnitude. Two methods of RF phase-stabilization were characterized: overcoupling with negative phase feedback, and also fast mechanical tuner feedback. The ? = 0.5 triple-spoke-loaded cavity RF field amplitude and phase errors were controlled to ±0.5% and ±30 respectively.

Conway, Z.↗

Electro-Mechanical Properties of Spoke-Loaded Superconducting Cavities

This paper presents experimental data characterizing the electro-mechanical properties of superconducting spoke-loaded cavities developed for high-intensity ion-linac applications, such as the cw ANL Advanced Exotic Beams Laboratory (AEBL) driver linac and the pulsed FNAL High Intensity Neutrino Source (HINS, now project X) proton driver linac. High-gradient cw operation at 4.2 K can produce violent boiling in the liquid helium coolant causing microphonic frequency noise. A spoke cavity designed to minimize the effects of helium pressure on RF eigenfrequency, the total microphonic induced RF frequency variations, were found to be on the level of the phase noise in the reference oscillator. To determine the pulsed cavity RF performance, the Lorentz transfer function was measured and used to predict the dynamic detuning in pulsed operation. There is good agreement between the predicted fit and the measured data, demonstrating the utility of the Lorentz transfer function, which can completely characterize the dynamics of the coupling between the mechanical cavity structure and the cavity RF field due to the Lorentz force.

Conway, Z.↗