Search NASA⌕ Search

Engineering topics

Cooper, Christopher B.

Publications and source records attributed to Cooper, Christopher B..

Sequence-dependent self-assembly of supramolecular nanofibers in periodic dynamic block copolymers

Block copolymers (BCPs) can spontaneously self-assemble into various nanostructured morphologies which enable their diverse applications in selective membranes, polymer electrolytes, and optoelectronics. To expand the range of nanostructures accessible to block copolymers, we designed dynamic block copolymers (DBCPs) that combine the phase separation of traditional block copolymers with the supramolecular self-assembly of periodic dynamic polymers. We demonstrate that DBCPs synthesized with a periodic block sequence self-assemble into high aspect ratio supramolecular nanofibers with well-ordered PEG and PDMS domains, in contrast to those synthesized with a random sequence which do not form nanofibers but have disordered morphologies. The periodicity of the block sequence ensures regular placement of dynamic bonds along the polymer chain, which enables stacking of the hydrogen bonding units into ordered 1D supramolecular nanofibers and delays the onset of terminal flow by up to 60 °C compared to the random block sequence. The hierarchically assembled supramolecular nanofibers display complex mechanical and thermal phase behavior arising from the interplay between phase separation of the dissimilar polymer backbones and supramolecular interactions between dynamic bonds. Despite identical bulk composition, the periodic DBCPs demonstrate ionic conductivity values over two orders of magnitude higher than their random counterparts due to the formation of well-ordered, interconnected, high aspect ratio ion-transporting PEG domains. In conclusion, these results highlight the potential for DBCPs as an emerging material platform to achieve advanced, self-assembled nanostructured morphologies.

36 MATERIALS SCIENCE↗

Autonomous alignment and healing in multilayer soft electronics using immiscible dynamic polymers

Self-healing soft electronic and robotic devices can, like human skin, recover autonomously from damage. While current devices use a single type of dynamic polymer for all functional layers to ensure strong interlayer adhesion, this approach requires manual layer alignment. In this study, we used two dynamic polymers, which have immiscible backbones but identical dynamic bonds, to maintain interlayer adhesion while enabling autonomous realignment during healing. These dynamic polymers exhibit a weakly interpenetrating and adhesive interface, whose width is tunable. When multilayered polymer films are misaligned after damage, these structures autonomously realign during healing to minimize interfacial free energy. Finally, we fabricated devices with conductive, dielectric, and magnetic particles that functionally heal after damage, enabling thin-film pressure sensors, magnetically assembled soft robots, and underwater circuit assembly.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Formation Mechanism of Flower-like Polyacrylonitrile Particles

Flower-like polyacrylonitrile (PAN) particles have shown promising performance for numerous applications, including sensors, catalysis, and energy storage. However, the detailed formation process of these unique structures during polymerization has not been investigated. Here, we elucidate the formation process of flower-like PAN particles through a series of in situ and ex situ experiments. We have the following key findings. First, lamellar petals within the flower-like particles were predominantly orthorhombic PAN crystals. Second, branching of the lamellae during the particle formation arose from PAN's fast nucleation and growth on pre-existing PAN crystals, which was driven by the poor solubility of PAN in the reaction solvent. Third, the particles were formed to maintain a constant center-to-center distance during the reaction. The separation distance was attributed to strong electrostatic repulsion, which resulted in the final particles' spherical shape and uniform size. Lastly, we employed the understanding of the formation mechanism to tune the PAN particles' morphology using several experimental parameters including incorporating comonomers, changing temperature, adding nucleation seeds, and adjusting the monomer concentration. Here these findings provide important insights into the bottom-up design of advanced nanostructured PAN-based materials and controlled polymer nanostructure self-assemblies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Computational approaches to model X-ray photon correlation spectroscopy from molecular dynamics

X-ray photon correlation spectroscopy (XPCS) allows for the resolution of dynamic processes within a material across a wide range of length and time scales. X-ray speckle visibility spectroscopy (XSVS) is a related method that uses a single diffraction pattern to probe ultrafast dynamics. Interpretation of the XPCS and XSVS data in terms of underlying physical processes is necessary to establish the connection between the macroscopic responses and the microstructural dynamics. To aid the interpretation of the XPCS and XSVS data, we present a computational framework to model these experiments by computing the X-ray scattering intensity directly from the atomic positions obtained from molecular dynamics simulations. We compare the efficiency and accuracy of two alternative computational methods: the direct method computing the intensity at each diffraction vector separately, and a method based on fast Fourier transform that computes the intensities at all diffraction vectors at once. Furthermore, the computed X-ray speckle patterns capture the density fluctuations over a range of length and time scales and are shown to reproduce the known properties and relations of experimental XPCS and XSVS for liquids.

36 MATERIALS SCIENCE↗

A molecular design approach towards elastic and multifunctional polymer electronics

Next-generation wearable electronics require enhanced mechanical robustness and device complexity. Besides previously reported softness and stretchability, desired merits for practical use include elasticity, solvent resistance, facile patternability and high charge carrier mobility. Here, we show a molecular design concept that simultaneously achieves all these targeted properties in both polymeric semiconductors and dielectrics, without compromising electrical performance. This is enabled by covalently-embedded in-situ rubber matrix (iRUM) formation through good mixing of iRUM precursors with polymer electronic materials, and finely-controlled composite film morphology built on azide crosslinking chemistry which leverages different reactivities with C–H and C=C bonds. The high covalent crosslinking density results in both superior elasticity and solvent resistance. When applied in stretchable transistors, the iRUM-semiconductor film retained its mobility after stretching to 100% strain, and exhibited record-high mobility retention of 1 cm 2 V -1 s -1 after 1000 stretching-releasing cycles at 50% strain. The cycling life was stably extended to 5000 cycles, five times longer than all reported semiconductors. Furthermore, we fabricated elastic transistors via consecutively photo-patterning of the dielectric and semiconducting layers, demonstrating the potential of solution-processed multilayer device manufacturing. The iRUM represents a molecule-level design approach towards robust skin-inspired electronics.

42 ENGINEERING↗

High Energy Density Shape Memory Polymers Using Strain-Induced Supramolecular Nanostructures

Shape memory polymers are promising materials in many emerging applications due to their large extensibility and excellent shape recovery. However, practical application of these polymers is limited by their poor energy densities (up to ~1 MJ/m 3 ). Here, we report an approach to achieve a high energy density, one-way shape memory polymer based on the formation of strain-induced supramolecular nanostructures. As polymer chains align during strain, strong directional dynamic bonds form, creating stable supramolecular nanostructures and trapping stretched chains in a highly elongated state. Upon heating, the dynamic bonds break, and stretched chains contract to their initial disordered state. This mechanism stores large amounts of entropic energy (as high as 19.6 MJ/m 3 or 17.9 J/g), almost six times higher than the best previously reported shape memory polymers while maintaining near 100% shape recovery and fixity. The reported phenomenon of strain-induced supramolecular structures offers a new approach toward achieving high energy density shape memory polymers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Design-to-Device Approach Affords Panchromatic Co-sensitized Solar Cells

Data–driven materials discovery has become increasingly important in identifying materials that exhibit specific, desirable properties from a vast chemical search space. Synergic prediction and experimental validation are needed to accelerate scientific advances related to critical societal applications. A design–to–device study that uses high–throughput screens with algorithmic encodings of structure–property relationships is reported to identify new materials with panchromatic optical absorption, whose photovoltaic device applications are then experimentally verified. The data–mining methods source 9431 dye candidates, which are auto–generated from the literature using a custom text–mining tool. These candidates are sifted via a data–mining workflow that is tailored to identify optimal combinations of organic dyes that have complementary optical absorption properties such that they can harvest all available sunlight when acting as co–sensitizers for dye–sensitized solar cells (DSSCs). Six promising dye combinations are shortlisted for device testing, whereupon one dye combination yields co–sensitized DSSCs with power conversion efficiencies comparable to those of the high–performance, organometallic dye, N719. Here, these results demonstrate how data–driven molecular engineering can accelerate materials discovery for panchromatic photovoltaic or other applications.

14 SOLAR ENERGY↗

A controlled statistical study to assess measurement variability as a function of test object position and configuration for automated surveillance in a multicenter longitudinal COPD study (SPIROMICS)

Purpose: A test object (phantom) is an important tool to evaluate comparability and stability of CT scanners used in multicenter and longitudinal studies. However, there are many sources of error that can interfere with the test object-derived quantitative measurements. Here the authors investigated three major possible sources of operator error in the use of a test object employed to assess pulmonary density-related as well as airway-related metrics. Methods: Two kinds of experiments were carried out to assess measurement variability caused by imperfect scanning status. The first one consisted of three experiments. A COPDGene test object was scanned using a dual source multidetector computed tomographic scanner (Siemens Somatom Flash) with the Subpopulations and Intermediate Outcome Measures in COPD Study (SPIROMICS) inspiration protocol (120 kV, 110 mAs, pitch = 1, slice thickness = 0.75 mm, slice spacing = 0.5 mm) to evaluate the effects of tilt angle, water bottle offset, and air bubble size. After analysis of these results, a guideline was reached in order to achieve more reliable results for this test object. Next the authors applied the above findings to 2272 test object scans collected over 4 years as part of the SPIROMICS study. The authors compared changes of the data consistency before and after excluding the scans that failed to pass the guideline. Results: This study established the following limits for the test object: tilt index ≤0.3, water bottle offset limits of [−6.6 mm, 7.4 mm], and no air bubble within the water bottle, where tilt index is a measure incorporating two tilt angles around x- and y-axis. With 95% confidence, the density measurement variation for all five interested materials in the test object (acrylic, water, lung, inside air, and outside air) resulting from all three error sources can be limited to ±0.9 HU (summed in quadrature), when all the requirements are satisfied. The authors applied these criteria to 2272 SPIROMICS scans and demonstrated a significant reduction in measurement variation associated with the test object. Conclusions: Three operator errors were identified which significantly affected the usability of the acquired scan images of the test object used for monitoring scanner stability in a multicenter study. The authors’ results demonstrated that at the time of test object scan receipt at a radiology core laboratory, quality control procedures should include an assessment of tilt index, water bottle offset, and air bubble size within the water bottle. Application of this methodology to 2272 SPIROMICS scans indicated that their findings were not limited to the scanner make and model used for the initial test but was generalizable to both Siemens and GE scanners which comprise the scanner types used within the SPIROMICS study.

60 APPLIED LIFE SCIENCES↗