Search NASA⌕ Search

Engineering topics

Coplan, M.

Publications and source records attributed to Coplan, M..

Plasma IMS Composition Measurements for Europa, Ganymede, and the Jovian Systems

NASA and ESA are now planning a reduced version of the joint Europa Jupiter System Mission (EJSM), potentially including a radically descoped Jupiter Europa Orbiter (JEO) but still with magnetometer and plasma instruments. Similar field and plasma instrumentation would also reside on ESA's Jupiter Ganymede Orbiter (JGO), which conceivably could carry out multiple flybys of Europa before entering orbit at Ganymede. We are developing the 3D Ion Mass Spectrometer (IMS) designed to measure both major and minor ion species within the high radiation environment of Jupiter s magnetosphere and the icy Galilean moons. The IMS covers the energy range from 10 eV to 30 keV, wide field-ofview (FOV) capability and 10-60 sec time resolution for major ions. This instrument has two main goals: 1) measure the plasma interaction between Europa and Jupiter s magnetosphere and 2) infer the global surface composition to trace elemental and significant isotopic levels; these goals are also applicable for in-situ measurements at Ganymede and Callisto, and remotely everywhere via the iogenic plasma for Io. The first goal supports the magnetometer (MAG) measurements, primarily directed at detection of Europa's sub-surface ocean, while the second goal gives information about transfer of material between the Galilean moons, e.g. mainly from Io to the other moons, and further allows detection of oceanic materials emergent to the moon surfaces from subsurface layers putatively including salt water oceans. Outgassed exospheric materials are probed by the IMS by measuring pickup ions accelerated up to spacecraft altitudes of approximately 100-200 km in electric fields extending through the local magnetospheric environment and moon exosphere to the surface. Our 3D hybrid kinetic model of the moon-magnetosphere interaction is used to construct a global model of electric and magnetic fields for tracing of pickup ion trajectories back to the sources at approximate surface resolution of 100 km. We show that Europa's exospheric ionosphere is dominated by pickup ions with energies of 100-1000 eV. We also expect field aligned polar ion outflows driven by ionospheric electrons via the polarization electric field at Europa; the IMS will observe such outflows and thus sample the ionosphere below spacecraft orbit altitude approximately 100 km. Based on previous Ganymede studies, we also comment on IMS applications to a Ganymede orbiter. The IMS and the Europa interaction model are respectively being developed with support from NASA's Astrobiology Instrument Development (ASTID) and Outer Planets Research (OPR) programs.

Sittler, E.↗

Plasma IMS Composition Measurements for Europa and Ganymede

NASA and ESA are planning the joint Europa Jupiter System Mission (EJSM) to the Jupiter system with specific emphasis to Europa and Ganymede, respectively. The Japanese Space Agency is also planning an orbiter mission to explore Jupiter's magnetosphere and the Galilean satellites. For NASA's Jupiter Europa Orbiter (JEO) we are developing the 3D Ion Mass Spectrometer (IMS) with two main goals which can also be applied to the other Galilean moons, 1) measure the plasma interaction between Europa and Jupiter's magnetosphere and 2) infer the 4n surface composition to trace elemental [1] and significant isotopic levels. The first goal supports the magnetometer (MAG) measurements, primarily directed at detection of Europa's sub-surface ocean, while the second gives information about transfer of material between the Galilean moons, and between the moon surfaces and subsurface layers putatively including oceans. The measurement of the interactions for all the Galilean moons can be used to trace the in situ ion measurements of pickup ions back to either Europa's or Ganymede's surface from the respectively orbiting spacecraft. The IMS instrument, being developed under NASA's Astrobiology Instrument Development Program, would maximally achieve plasma measurement requirements for JEO and EJSM while moving forward our knowledge of Jupiter system composition and source processes to far higher levels than previously envisaged.

Sittler, E.↗

Fisk-Gloeckler Suprathermal Proton Spectrum in the Heliosheath and the Local Interstellar Medium

Convergence of suprathermal keV-MeV proton and ion spectra approximately to the Fisk-Gloeckler (F-G) form j(E) = j(sub 0) E(sup -1.5) in Voyager land 2 heliosheath measurements is suggestive of distributed acceleration in Kolmogorov turbulence which may extend well beyond the heliopause into the local interstellar medium (LISM). Turbulence of this type is already indicated by interstellar radio scintillation measurements of electron density power spectra. Previously published extrapolations (Cooper et al., 2003, 2006) of the LISM proton spectrum from eV to GeV energies are highly consistent with the F-G power-law and further indicative of such turbulence and LISM effectiveness of the F-G cascade acceleration process. The LISM pressure computed from this spectrum well exceeds that from current estimates for the LISM magnetic field, so exchange of energy between the protons and the magnetic field would likely have a strong role in evolution of the turbulence as per the F-G theory and as long ago proposed for cosmic ray energies by Parker and others. Pressure-dependent estimates of the LISM field strength should not ignore this potentially strong and even dominant contribution from the plasma. Presence of high-beta suprathermal plasma on LISM field lines could significantly affect interactions with the heliospheric outer boundary region and might potentially account for distributed and more discrete features in ongoing measurements of energetic neutral emission from the Interstellar Boundary Explorer (IBEX) mission.

Cooper, John F.↗

Optimization of Neutral Atom Imagers

The interactions between plasma structures and neutral atom populations in interplanetary space can be effectively studied with energetic neutral atom imagers. For neutral atoms with energies less than 1 keV, the most efficient detection method that preserves direction and energy information is conversion to negative ions on surfaces. We have examined a variety of surface materials and conversion geometries in order to identify the factors that determine conversion efficiency. For chemically and physically stable surfaces smoothness is of primary importance while properties such as work function have no obvious correlation to conversion efficiency. For the noble metals, tungsten, silicon, and graphite with comparable smoothness, conversion efficiency varies by a factor of two to three. We have also examined the way in which surface conversion efficiency varies with the angle of incidence of the neutral atom and have found that the highest efficiencies are obtained at angles of incidence greater then 80deg. The conversion efficiency of silicon, tungsten and graphite were examined most closely and the energy dependent variation of conversion efficiency measured over a range of incident angles. We have also developed methods for micromachining silicon in order to reduce the volume to surface area over that of a single flat surface and have been able to reduce volume to surface area ratios by up to a factor of 60. With smooth micro-machined surfaces of the optimum geometry, conversion efficiencies can be increased by an order of magnitude over instruments like LENA on the IMAGE spacecraft without increase the instruments mass or volume.

Shappirio, M.↗

Seeking to Improve Low Energy Neutral Atom Detection in Space

The detection of energetic neutral atoms allows for the remote examination of the interactions between plasmas and neutral populations in space. Before these neutral atoms can be measured, they must first be converted to ions. For the low energy end of this spectrum, interaction with a conversion surface is often the most efficient method to convert neutrals into ions. It is generally thought that the most efficient surfaces are low work functions materials. However, by their very nature, these surfaces are highly reactive and unstable, and therefore are not suitable for space missions where conditions cannot be controlled as they are in a laboratory. We therefore are looking to optimize a stable surface for conversion efficiency. Conversion efficiency can be increased either by changing the incident angle of the neutral particles to be grazing incidence and using stable surfaces with high conversion efficiencies. We have examined how to increase the angle of incidence from -80 degrees to -89 degrees, while maintaining or improving the total active conversion surface area without increasing the overall volume of the instrument. We are developing a method to micro-machine silicon, which will reduce the volume to surface area ratio by a factor of 60. We have also examined the material properties that affect the conversion efficiency of the surface for stable surfaces. Some of the parameters we have examined are work function, smoothness, and bond structure. We find that for stable surfaces, the most important property is the smoothness of the surface.

Shappirio, M.↗

Remote Sensing of Icy Galilean Moon Surface and Atmospheric Composition Using Low Energy (1 eV-4 keV) Neutral Atom Imaging

We describe a low energy neutral atom imager suitable for composition measurements Europa and other icy Galilean moons in the Jovian magnetosphere. This instrument employs conversion surface technology and is sensitive to either neutrals converted to negative ions, neutrals converted to positive ions and the positive ions themselves depending on the power supply. On a mission such as the Jupiter Icy Moons Orbiter (JIMO), two back-to-back sensors would be flown with separate power supplies fitted to the neutral atom and iodneutral atom sides. This will allow both remote imaging of 1 eV < E < 4 keV neutrals from icy moon surfaces and atmospheres, and in situ measurements of ions at similar energies in the moon ionospheres and Jovian magnetospheric plasma. The instrument provides composition measurements of the neutrals and ions that enter the spectrometer with a mass resolution dependent on the time-of-flight subsystem and capable of resolving molecules. The lower energy neutrals, up to tens of eV, arise from atoms and molecules sputtered off the moon surfaces and out of the moon atmospheres by impacts of more energetic (keV to MeV) ions from the magnetosphere. Direct Simulation Monte Carlo (DSMC) models are used to convert measured neutral abundances to compositional distributions of primary and trace species in the sputtered surfaces and atmospheres. The escaping neutrals can also be detected as ions after photo- or plasma-ionization and pickup. Higher energy, keV neutrals come from charge exchange of magnetospheric ions in the moon atmospheres and provide information on atmospheric structure. At the jovicentric orbits of the icy moons the presence of toroidal gas clouds, as detected at Europa's orbit, provide M e r opportunities to analyze both the composition of neutrals and ions originating from the moon surfaces, and the characteristics of magnetospheric ions interacting with neutral cloud material. Charge exchange of low energy ions near the moons, and directional distributions of the resultant neutrals, allow indirect global mapping of magnetic field structures around the moons. Temporal variation of the magnetic structures can be linked to induced magnetic fields associated with subsurface oceans.

Collier, M. R.↗

CELIAS: Charge, Element and Isotope Analysis System for the SOHO mission

The status and further development as well as first calibration of the CELIAS experiment on SOHO is presented. CELIAS is designed to measure the mass, ionic charge, and energy of low and high speed solar wind of suprathermal ions and of low energy flare particles. Through analysis of the elemental and isotopic abundances (the ionic charge state and velocity distributions of ions originating on the solar atmosphere), the investigation focuses on studying the plasma processes in various temporal and spatial scales in the solar chromosphere, transition zone, and corona. Additionally, the CELIAS experiment includes the Solar EUV Monitor (SEM). This unit, which consists of an EUV transmission grating spectrometer and three isolated silicon photodiodes as detectors, is described. The three mass and charge discriminating sensors based on the time of flight technique are also described.

Hovestadt, D.↗

Ion optical design with applications to a solar wind mass spectrometer

The design of charged particle beam transport systems at lower energies is discussed. Topics discussed include: index of refraction, photometry, phase space, matrices, lenses and imaging, charged particle trajectories in crossed electric and magnetic fields, design parameters for the Wien filter, and electrostatic energy analyzer design, an annotated bibliography is presented.

Coplan, M.↗