Search NASA⌕ Search

Engineering topics

Corredor, Andrew

Publications and source records attributed to Corredor, Andrew.

Ultraviolet digital holographic microscopy (DHM) of micron-scale particles from shocked Sn ejecta

A cloud of very fast, O (km/s), and very fine, O (µm), particles may be ejected when a strong shock impacts and possibly melts the free surface of a solid metal. To quantify these dynamics, this work develops an ultraviolet, long-working distance, two-pulse Digital Holographic Microscopy (DHM) configuration and is the first to replace film recording with digital sensors for this challenging application. A proposed multi-iteration DHM processing algorithm is demonstrated for automated measures of the sizes, velocities, and three-dimensional positions of non-spherical particles. Ejecta as small as 2 µm diameter are successfully tracked, while uncertainty simulations indicate that particle size distributions are accurately quantified for diameters ≥4 µm. These techniques are demonstrated on three explosively driven experiments. Measured ejecta size and velocity statistics are shown to be consistent with prior film-based recording, while also revealing spatial variations in velocities and 3D positions that have yet to be widely investigated. Having eliminated time-consuming analog film processing, the methodologies proposed here are expected to significantly accelerate future experimental investigation of ejecta physics.

47 OTHER INSTRUMENTATION↗

New Design Yields Robust Large-Area Framing Camera

Manuscript to be submitted to Review of Scientific Instruments to determine interest in possible publication. Website: https://aip.scitation.org/rsi/authors/manuscript High-speed imaging is a core diagnostic capability for the Nevada National Security Site (NNSS). Data from experiments that measure the behavior of materials under extreme conditions are essential for the stockpile mission. For example, during subcritical experiments, materials that are shocked and compressed under high-explosive drive change behavior rapidly over timescales measured in millionths or even billionths of a second. Characterizing and understanding this behavior requires radiographic and/or optical imaging to track motion on these timescales. Framing cameras provide a discrete series of images over a short period of time in a manner that mimics a high-speed movie camera, but with individual shutter times that must be extremely short in order to capture freeze-frame images of rapidly evolving phenomena such as high-explosive shock-driven ejecta, dynamic compression of metals, and high-velocity fluid flow.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-energy radiographic imaging performance of LYSO

Here, a comprehensive comparison of the dominant sources of radiation-induced blur for radiographic imaging system performance is made. End-point energies of 6, 10, 15, and 20 MeV bremsstrahlung photon radiation produced at the Los Alamos National Laboratory Microtron facility were used to examine the performance of large-panel cerium-doped lutetium yttrium silicon oxide (LYSO:Ce) scintillators 3, 5 and 10 mm thick. The system resolution was measured and compared between the various end-point energies and scintillator thicknesses. Contrary to expectations, it is found that there was only a minor dependence of system resolution on scintillator thickness or beam end-point energy. This indicates that increased scintillator thickness does not have a dramatic effect on system performance. The data are then compared to Geant4 simulations to assess contributions to the system performance through the examination of modulation transfer functions. It was determined that the low-frequency response of the system is dominated by the radiation-induced signal, while the higher-frequency response of the system is dominated by the optical imaging of the scintillation emission.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MCNP Estimates of Scatter Sources at the FXR CFF

This is an unclassified presentation on Monte Carlo simulated observations estimated at the FXR CFF and comparisons to actual measurements are quantified appropriately.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Design Guidelines for Predicting Stress in Cemented Doublets Undergoing Temperature Change

This work explores quick predictive methods for calculating potentially risky stresses in cemented doublets underdoing temperature change that agree well with finite element analysis. We also provide guidelines for avoiding stress concentrations. Cemented doublets are ubiquitous in the optics world, but it is not always clear if they will perform as intended in a specific thermal environment due to excessive stress. The stress in the optic can cause debonding or even fracture. Yoder addressed this problem using analytical results from Chen and Nelson but also expressed some skepticism as to the accuracy and usefulness of those results. Closed-form analytical solutions are extremely useful when doing trade-off studies to see if a particular geometry or glass choice will cause stress problems. The problem of bonded materials undergoing temperature change is of great interest in the electronics industry, and improved analytical solutions are now available that address the issues raised by Yoder, and they have been validated using finite element analysis (FEA). But the newer solutions still have limitations. The analytical solutions presented here cannot predict stresses due to stress concentrations or singularities at the edge of the bondline—this still has to be done using FEA—although some advanced methods are available. Also, the existing analytical methods assume a flat interface between adjoining elements; they do not account for the effect of curvature. We find that most doublet failures start at the edges and involve debonding of the glass. Glass fracture is rare for doublets, accounting for less than 10% of the failures. This paper provides the reader with a general introduction to a large and dense body of literature in order to demystify the subject of temperature-induced glass bonding failures.

36 MATERIALS SCIENCE↗

Disentangling Radiographic Contributions

Presentation describes research program and goal to understand all large radiographic contributions for a given image and assess if quantitative predictions can be made once contributions are understood, with current focus understanding scintillator response.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Flash Radiography Studies with Microcolumnar CsI

There is growing interest in using low-energy flash x-ray sources in radiographic applications to provide high-contrast images of low-density objects. Due to the low-energy nature of the detected photons, thin bright scintillators are desired. In order to pursue an optimum radiographic system, experimental studies have been performed of the static imaging properties of thin microcolumnar CsI using a Platts x-ray source. The Platts source is a nominally 300 keV endpoint rod pinch diode x-ray source with a ~35 ns pulse time. The source was used to measure the imaging properties of microcolumnar CsI with various thicknesses and backings. The experimental setup was modeled in GEANT4, and the images were simulated to estimate system performance. Taking into account the source photon production, radiation transport, and system optical performance, an accurate assessment of the detection system can be deduced.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cygnus Zoom Lens Autofocus Capability

Presentation describes work on the Cygnus zoom lens autofocus, to include gimbal mount redesign, autofocus program development, camera tip/tilt and focus program development, and the zoom lens system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗