Robust Dual Optical Frequency Comb Spectroscopy System for Greenhouse Gas Monitoring
Explore the source record for details and available documents.
Engineering topics
Publications and source records attributed to Cossel, Kevin.
Explore the source record for details and available documents.
ARPA-E investment in long-range, frequency comb-based methane detection has resulted in the first scalable, cost-effective continuous methane emissions system. At the onset of this ARPA-E MONITOR award, the dual-frequency comb spectrometer was a sprawling, expensive, laboratory-confined device which had only recently been demonstrated capable of measuring atmospheric trace gases over open-paths. Bringing the technology to the point of being able to monitor for and characterize methane emissions at oil and natural gas production facilities seemed an almost impossible task. Over the subsequent months and years, our team transitioned the Nobel-prize-winning frequency-comb-laser spectrometer technology to a field-deployed regional methane leak detection system. The spectrometer enables highly sensitive near-infrared absorption measurements of methane along kilometer-scale laser beam paths. The measurements are coupled with an atmospheric modeling and inversion framework to triangulate the location of emission sources and quantify the emission rates.
A new method is tested in a single-blind study for detection, attribution, and quantification of methane emissions from the natural gas supply chain, which contribute substantially to annual U.S. emissions. The monitoring approach couples atmospheric methane concentration measurements from an open-path dual frequency comb laser spectrometer with meteorological data in an inversion to characterize emissions. During single-blind testing, the spectrometer is placed >1 km from decommissioned natural gas equipment configured with intentional leaks of control- lable rate. Single, steady emissions ranging from 0 to 10.7 g min -1 (0-34.7 scfh) are detected, located, and quantified at three gas pads of varying size and complexity. The system detects 100% of leaks, including leaks as small as 0.96 g min -1 (3.1 scfh). It attributes leaks to the correct pad or equipment group (tank battery, separator battery, wellhead battery) 100% of the time and to the correct equipment (specific separator, tank, or wellhead) 67% of the time. All leaks are quantified to within 3.7 g min -1 (12 scfh); 94% are quantified to within 2.8 g min -1 (9 scfh). Finally, these tests are an important initial demonstration of the methodology’s viability for continuous monitoring of large regions, with extension to other trace gases and industries.
Not Available