Search NASA⌕ Search

Engineering topics

Cottrell, Elizabeth

Publications and source records attributed to Cottrell, Elizabeth.

Fe Kα XANES, Fe Kβ HERFD XANES and EPMA flank method determinations of the oxidation state of Fe in garnet

The ferric to total iron ratios (Fe 3+ /ΣFe) of garnets can be paired with thermodynamic mineral activity models to quantify the oxygen fugacity of garnet-bearing rocks. However, techniques with a high analytical and spatial resolution are necessary to distinguish differences in garnet Fe 3+ /ΣFe ratios at the percent level and to accurately measure garnets that are zoned or contain inclusions. We acquired conventional Fe Kα and high-resolution energy fluorescence detection (HERFD) Fe Kβ X-ray absorption near edge structure (XANES) spectra and electron microprobe flank method analyses on a suite of 27 peridotitic and eclogitic garnets with Fe 3+ /ΣFe ratios previously determined by Mössbauer spectroscopy to evaluate the precision of each technique. We examined variations in the energy and intensity of three XANES spectral features as a function of Fe 3+ /ΣFe ratios: 1) the intensity ratio of two-post edge features (I-ratio; Fe Kα only); 2) the energy of the Fe edge at 90% normalized intensity (E 0.9 ; Fe Kα only) and 3) the pre-edge centroid energy (Fe Kα and HERFD Fe Kβ). In accordance with previous work, we find the energies of garnet pre-edge centroids are relatively insensitive to Fe 3+ /ΣFe ratios. The I-ratios of peridotitic and eclogitic garnets are offset from each other at low Fe 3+ /ΣFe ratios (≤0.13); I-ratio garnet XANES calibrations are composition-specific. The E 0.9 feature is independent of garnet major element composition in spectra that have been corrected for the effects of self-absorption. We produce two Fe Kα garnet XANES calibrations based on variations in the E0.9 feature; one calibration with all garnet reference materials included (Fe 3+ /ΣFe up to 1.0; “all garnet calibration”) and another calibration specific to garnets with low Fe 3+ /ΣFe ratios (“low ferric calibration”). Fe 3+ /ΣFe ratios calculated from the mean of up to 25 flank method measurements on eight garnet reference materials fall within 4% absolute of a one-to-one correlation with Fe 3+ /ΣFe ratios measured by Mössbauer. The standard error of the mean Fe 3+ /ΣFe ratio calculated from flank method approaches the Mössbauer-determined Fe 3+ /ΣFe ratio within estimated error (3%) after three analyses. Flank method precision is enhanced at higher beam current; however, the precision of the flank method does not approach the precision of XANES under any microprobe analytical condition tested here. Garnet reference materials detailed here are available by request to the Smithsonian Institution.

58 GEOSCIENCES↗

No detectable redox exchange between sulfur and iron during rapid cooling of basalts

The valence states of iron and sulfur in mantle-derived melts influence and respond to the composition of the mantle as well as the subsequent evolution of those melts in Earth's crust. Characterizing the valence states of iron and sulfur in silicate melts that have quenched to form glasses is therefore critical to understanding the composition of the mantle and the magmatic processes that take place before and during volcanic eruptions. Glasses quenched from silicate melts offer the opportunity to precisely measure sulfur and iron valence states, but whether the transition from melt to glass affects the valence state of sulfur and iron is uncertain. Here, we use the glassy margins of two pillow basalts, one from a mid-ocean ridge and one from a back-arc basin, as a natural experiment to test the effect of quench rate on sulfur and iron valence states. We report micro-X-ray Absorption Near Edge Structure (XANES) measurements of S 6+ /ΣS (S 6+ /[S 6+ +S 2- ]) and Fe 3+ /ΣFe (Fe 3+ /[Fe 2+ +Fe 3+ ]) along transects from the rapidly quenched rims of the pillows down into the slowly cooled crystal-rich interiors. The range of average quench rates estimated for our selected analysis areas range from 1.2 x 10 5 °C/sec at the pillow margin to 1.1 °C/sec in the interior and span quench rates experienced by natural and experimental glasses. On average, S6+/ΣS = 0.09 ± 0.01 and Fe 3+ /ΣFe = 0.147 ± 0.002 in the mid-ocean ridge sample and S 6+ /ΣS = 0.21 ± 0.01and Fe 3+ /ΣFe = 0.153 ± 0.004 in the back-arc sample, where the quoted uncertainty is the 1σ standard deviation of n= 9-16 analyses. We find that the S 6+ /ΣS and Fe 3+ /ΣFe values along transects in each sample show no systematic changes with depth, and by proxy, no systematic changes with quench rate. In each pillow, all measured S 6+ /ΣS and Fe 3+ /ΣFe ratios are within the absolute uncertainty of each technique. We propose that these observations are consistent with either sluggish reaction kinetics between sulfur and iron, or an insignificant temperature effect on sulfur-iron redox exchange equilibria. These observations demonstrate that sulfur and iron valence states in glasses with varying quench rates can be directly compared, and that changes in sulfur and iron valence during quench are below the limits of detection with XANES.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Garnet crystallization does not drive oxidation at arcs

Arc magmas, the building blocks of continental crust, are depleted in total iron (Fe), have higher ratios of oxidized Fe to total Fe (Fe 3+ /∑Fe), and record higher oxygen fugacities ( f O 2 ’s) compared with magmas erupted at mid-ocean ridges. Garnet crystallization could explain these observations if garnet removes substantial amounts of Fe 2+ , but not Fe 3+ , from magma, yet this model for continental crust generation has never been tested experimentally. Analysis of garnets and melts in laboratory experiments show that the compatibilities of Fe 2+ and Fe 3+ in garnet are of similar magnitudes. Our results indicate that fractional crystallization of garnet-bearing cumulates will remove 22 % of total Fe from primary arc basalts but negligibly alter the Fe 3+ /∑Fe ratio and f O 2 of the melt. Garnet crystallization is unlikely to be responsible for the relatively oxidized nature of basaltic arc magmas or the Fe-depletion trend observed in continental crust.

Science & Technology - Other Topics↗