169 Tm(n,$\gamma$) cross section measured at DANCE

During the US nuclear testing program, known tracer materials could be loaded into the device prior to detonation. If those materials had activation products from nuclear reactions, they could be recovered and counted post-test to study how they transmuted during the neutron exposure. This information may be used to try to infer information about the physical conditions during the detonation. These materials are often referred to as “radiochemical detectors” or “radiochemical tracers”. Thulium, which has only one stable isotope, thulium-169, is one such material that may be employed as a detector.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Delivery of LiH Shell for DANCE

Material for a new LiH shell for neutron shielding has been obtained for the Detector for Advanced Neutron Capture Experiments. This is a critical component for optimizing sensitivity of neutron capture experiments performed in support of Office of Experimental Sciences mission, particularly in the case of small, rare samples.

42 ENGINEERING↗

GEANT4 code for DANCE with NEUANCE detector-response simulations

A new GEANT4 model for DANCE with NEUANCE has been developed to account for the change in the DANCE configuration when NEUANCE is installed. In this model, the energy resolution and the shape of the threshold of the individual DANCE detectors are used as an input to provide realistic representation of the measured γ-ray spectra. In addition, the distance from each detector to the target is defined in an input file as well as the physical presence of the a detector in the DANCE and NEUANCE arrays. The azimuthal angle of NEUANCE is also an external parameter to be tuned to represent the measurement. Simulated spectra are compared with measurements with standard γ-ray calibrated sources.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Carbon Block Density

Within the framework of the Neutron Target Demonstrator about 1 m 3 of reactor grade graphite is available at LANSCE. In order to evaluate its suitability as a moderator, knowledge about the exact density is important, since it strongly affects the average time neutrons spend in the volume. The graphite is available in different shapes. A brief analysis was done on three different carbon blocks to determine the density of the material as well as the uncertainty in that measurement.

36 MATERIALS SCIENCE↗

Neutron-induced capture-to-fission cross section ratio measured at LANSCE

Capture-to-fission cross section ratios are used as an alternative to absolute cross section measurements. This is due to the simplification on the calculations and the reduction of the uncertainties with respect to an absolute measurement of the cross section by eliminating experimental complications like self-absorption, beam/target overlap and non-uniformities. Different capture-to-fission reactions have been measured through the years at the Los Alamos Neutron Science Center (LANSCE) at Los Alamos National Laboratory (LANL) using the Detector for Advanced Neutron Capture Experiments (DANCE) combined with different fission detectors. Some of these are a Parallel Plate Avalanche Counter (PPAC) to detect fission fragments (FF), and the NEUtron detector array at DANCE (NEUANCE) to detect fission neutrons. As DANCE detects the γ-rays produced in capture and fission reactions, the fission instrument placed inside the DANCE cavity is used to tag the fission γ-rays for background identification and subtraction. Some examples of capture-to-fission ratio measurements performed with DANCE in the last years are the 233 U, 235 U and 239 Pu. The measurement technique, the different setups, and other potential applications of the instruments will be explained.

Nuclear Criticality Safety Program (NCSP)↗

Background simulations for DANCE, FP-14 considering the Mark IV spallation target

With the installation of the Mark-IV target at LANSCE in 2022 significant changes of the beam-related backgrounds at DANCE are observed. DANCE is located at flight path 14 (FP-14) in the experimental area 2 (ER-2) at LANSCE. This new background is so severe that the array is not operational for several microseconds after the protons hit the spallation target (Figures 1 - 3).

43 PARTICLE ACCELERATORS↗

Cubical moderators for the Neutron Target Demonstator (NTD)

Neutron capture cross sections of unstable isotopes are important for neutron induced nucleosynthesis as well as for technological applications. The traditional time-of-flight method reaches its limits once the necessary detection of the reaction products is hampered by the size (mass) of the sample. Several factors may limit the sample mass: The decay properties of radioactive isotopes interfere with the signals from the neutron capture or neutron-induced fission reactions; The limited range of charged reaction products requires a thin sample. In both cases, an increased neutron fluence at the sample position with ever improved neutron sources overcomes the lack of reaction rate. Reference proposed a combination of a radioactive beam facility, an ion storage ring and a spallation neutron source surrounded by neutron moderator. This idea is part of the LANSCE strategy to stay a worldwide leader for neutron induced research. Figure 1 shows a sketch of the proposed future setup.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Study of 149 Sm Capture and Total Cross Sections for Burnup Credit Applications [Slides]

This presentation highlights how capture and transmission measurements were performed with the DANCE (Detector for Advanced Neutron Capture Experiments) instrument with capture data from 8 eV – 1 keV, and DICER (Device for Indirect Capture Experiments on Radionuclides) instruments with transmission data from 1meV – 1 keV. There were additional measurements of 147 Sm which had contaminant in the samples, 3.4 eV strong resonance, interesting abnormalities. The data analysis is complete and the R-Matrix analysis almost (90%) complete.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The new Device for Indirect Capture Experiments on Radionuclides at LANSCE: Efforts on measuring the resonance(s) responsible for the extremely large 88 Zr (n,γ) cross section

The thermal neutron capture cross section of 88 Zr was recently reported to be the second largest in nature with the largest resonance integral measured. Presumably, these very large values are caused by a resonance or resonances very near thermal energy. Determining their energies and widths, and hence the shape of the cross section away from thermal energies,is useful for applications. The short half-life (83.4 days) and associated large background, renders direct measurements of the neutron capture cross section impossible using current techniques. However, it is possible to measure the total neutron cross section, and hence the resonance properties, using the newly commissioned Device for Indirect Capture Experiments on Radionuclides (DICER) at the Los Alamos Neutron Science Center (LANSCE). Transmission measurements are utilized as a surrogate method to perform capture measurements. The 88 Zr needed for a DICER measurement was produced at the Isotope Production Facility (IPF) and cleanly separated from the production target material. A description of the new instrument, efforts and preliminary results on 88 Zr will be presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The LANSCE experimental program: accelerator requirements

The LANSCE accelerator complex exploits a flexible, high power 800 MeV proton linear accelerator to enable a broad swath of experimental work supporting multiple scientific programs. The beam requirements for these programs are diverse and change over time. The purpose of this document is to record, at a high level, the experimental requirements driving the beam delivery requirements for each experimental facility at LANSCE. Revision 0 serves to baseline the current set of experiments, and we expect to revise the document on an as-needed basis when either the experimental requirements change or are found to require a more complete definition.

43 PARTICLE ACCELERATORS↗