Search NASA⌕ Search

Engineering topics

Cowin, James P

Publications and source records attributed to Cowin, James P.

Theoretical analyses of aerosol aging on a substrate without wall-effects by a cross-flow

Long time ({approx}1 day) aging or reactions of aerosol is typically studied using either large aerosol chambers (> 10 m3) or particles supported on a substrate to minimize wall effects. To avoid wall effects in the latter, it is often essential that the wall reactivity be extremely small (<< 10-5 reactions per encounter) and that the particle loadings be very small (< 1 pg/cm2) to eliminate transport-limited trace gas depletion near the particles and substrate. We evaluate here a cross-flow approach, which greatly reduces these constraints. Particles are to be supported on a micromesh ({approx}50% or more open area) through which the reactive gas is drawn at around a few hundred cm/s. The analysis shows how the competitions between flow and diffusion establishes a 'zone of isolation' several microns wide around each reactive particle, outside of which the reactivity of other particles or the substrate are irrelevant to the local reactions. This cross-flow approach reduces the effects of substrate and collective particle reactivity typically orders of magnitude, and will facilitate aging studies of supported aerosols.

54 ENVIRONMENTAL SCIENCES↗

Making a Hybrid Microfluidic Platform Compatible for In Situ Imaging by Vacuum-Based Techniques

A self-contained microfluidic-based device was designed and fabricated for in situ imaging of aqueous surfaces using vacuum techniques. The device is a hybrid between a microfluidic PDMS block and external accessories, all portable on a small platform (10 cm-8 cm). The key feature is that a small aperture with a diameter of 2-3 micrometers is opened to the vacuum, which serves as a detection window for in situ imaging of aqueous surfaces. Vacuum compatibility and temperature drop due to water vaporization are the two most important challenges in this invention. Theoretical calculations and fabrication strategies are presented from multiple design aspects. In addition, results from the time-of-flight secondary ion mass spectrometry (ToF-SIMS) of aqueous surfaces are presented.

54 ENVIRONMENTAL SCIENCES↗

Probing Aqueous Surfaces by ToF-SIMS

We report the first observations of aqueous surfaces by a time-of-flight secondary ion mass spectrometer (ToF-SIMS) via a self-contained microfluidic module compatible in vacuum. The interface uses a microfluidic channel with a 3 {micro}m diameter window into the flowing fluid beneath it. This window supports the liquid against the vacuum by the liquid's surface tension and limits the high-density vapor region traversed by the probe beams to only a few micrometers. We demonstrate detections of aqueous surfaces such as deuterium water and sodium iodide (NaI) solution through the small aperture by ToF-SIMS. Even more, molecular signals (M-H-) of glutamic acid (C5H8NO4-) are observed. ToF-SIMS coupled with the novel interface provides a molecular recognition capability, making it a great choice to detect short-lifetime reaction intermediates in aqueous solutions. This novel microfluidic interface makes multimodal vacuum based analysis of liquid surface possible.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Probing Liquid Surfaces under Vacuum Using SEM and TOF-SIMS

Applying vacuum-based molecular probes of liquid surfaces would aid many environmental, biological, and industrial studies. However the high vapor pressure of water and most organic solvents largely prohibit this use. We report a newly developed versatile and self-contained vacuum interface for high-vapor pressure liquid surfaces, and its application in a time of flight secondary ion mass spectrometer (TOFSIMS) and scanning electron microscope (SEM). The self-contained module requires no wires or tubing connections to the outside of the instrument. It uses a microfluidic channel with a 3 micrometer diameter window into the flowing fluid beneath it. This window supports the liquid against the vacuum by the liquid’s surface tension, while limiting the high-density vapor region traversed by the probe beams to only a few microns. This aperture size also limits temperature and concentration changes due to evaporation of the solvent. The beam damage caused by the probe beams is largely negligible, as the flowing liquid surface self-renews. We demonstrate the performance of this microfluidic interface for in situ liquid surface TOFSIMS (ISLS-TOFSIMS) and SEM (ISLS-SEM) for chemical analysis of liquid surfaces. This device enables in situ liquid (ISL) studies in a wide range of vacuum analytical methods beyond SEM and TOFSIMS.

99 GENERAL AND MISCELLANEOUS↗

Fast Time-Resolved Aerosol Collector: Proof of Concept

Atmospheric particles can be collected in the field on substrates for subsequent laboratory analysis via chemically sensitive single particle methods such as scanning electron microscopy with energy dispersed x-ray analysis. With moving substrates one can achieve time resolution of seconds to minutes. We demonstrate how to increase the time resolution to a few milliseconds to provide real-time information in this paper. Our fast time-resolved aerosol collector (“Fast-TRAC”) microscopically observes the particle collection on substrate and record an on-line video. Particle arrivals are resolved to within a single frame (17 to 4 ms in this setup), and the spatial locations are matched to the subsequent single particle analysis. This approach provides real-time information on particle size and number concentration. Applications are expected in airborne studies of cloud microstructure, pollution plumes, and long term site monitoring.

54 ENVIRONMENTAL SCIENCES↗

The Oil-Water Interface: Mapping the Solvation Potential

Ions moving across the oil water interface are strongly impacted by the continuous changes in solvation. The solvation potential for Cs+ is directly measured as they approach the oil-water interface (“oil” = 3-methylpentane), from 0.4 to 4 nm away. The oil-water interfaces are created at 40K using molecular beam epitaxy and a softlanding ion beam, with pre-placed ions. The solvation potential slope was determined at each distance by balancing it against an increasing electrostatic potential made by increasing the number of imbedded ions at that distance, and monitoring the resulting ion motion. The potential approaches the Born model for greater than z>0.4nm, and shows the predicted reduction of the polarizability at z<0.4nm.

36 MATERIALS SCIENCE↗

Proton segregation on a Growing Ice Interface

Hydronium segregates to the surface of H2O (D2O) ice films grown on Pt(111) above 151K (158K). This is observed as from the voltage that develops across the films, utilizing work function measurements. The dependence of this voltage on the film’s thickness is explained by a simple equilibrium model: as the film grows, most of the surface ions migrate so as to remain at the ice-vacuum interface, while a fixed percentage (~0.05%) take the thermodynamically-unfavored route, to become incorporated into the growing bulk ice. This model implies a delta-G of about +0.1eV for the movement of ions from the ice surface into the bulk ice.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗