DEVELOPMENT OF A SMALL INTEGRATED HEAT PUMP (IHP) FOR NET ZERO ENERGY HOMES

An IHP prototype was developed and tested over a range of operating modes and conditions. Test data was used to validate a detailed analysis model and the validated analytical tool was used to calculate the yearly performance of air- and ground-source IHP system designs optimized for R-410A in five major US cities. For the air-source IHP version, the simulation results showed ~46-67% energy savings depending upon location. For the ground-source IHP version, the simulation showed over 50% savings in all locations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hot Water Distribution System Program Documentation and Comparison to Experimental Data

In 2003, the California Energy Commission s (CEC s) Public Interest Energy Research (PIER) program funded Oak Ridge National Laboratory (ORNL) to create a computer program to analyze hot water distribution systems for single family residences, and to perform such analyses for a selection of houses. This effort and its results were documented in a report provided to CEC in March, 2004 [1]. The principal objective of effort was to compare the water and energy wasted between various possible hot water distribution systems for various different house designs. It was presumed that water being provided to a user would be considered suitably warm when it reached 105 F. Therefore, what was needed was a tool which could compute the time it takes for water reaching the draw point to reach 105 F, and the energy wasted during this wait. The computer program used to perform the analyses was a combination of a calculational core, produced by Dr. Keith A. Woodbury, Professor of Mechanical Engineering and Director, Alabama Industrial Assessment Center, University of Alabama, and a user interface based on LabVIEW, created by Dr. Roberto Lenarduzzi of ORNL. At that time, the computer program was in a relatively rough and undocumented form adequate to perform the contracted work but not in a condition where it could be readily used by those not involved in its generation. Subsequently, the CEC provided funding through Lawrence Berkeley National Laboratory (LBNL) to improve the program s documentation and user interface to facilitate use by others, and to compare the program s results to experimental data generated by Dr. Carl Hiller. This report describes the program and provides user guidance. It also summarizes the comparisons made to experimental data, along with options built into the program specifically to allow these comparisons. These options were necessitated by the fact that some of the experimental data required options and features not originally included in the program. A more detailed description of these program modifications along with detailed comparisons to the experimental data are provided in a report produced by Dr. Woodbury, which accompanies this report as Appendix H.

42 ENGINEERING↗

Ground-Source Integrated Heat Pump for Near-Zero Energy Houses: Technology Status Report

The energy service needs of a net-zero-energy house (ZEH) include space heating and cooling, water heating, ventilation, dehumidification, and humidification, depending on the requirements of the specific location. These requirements differ in significant ways from those of current housing. For instance, the most recent DOE buildings energy data (DOE/BED 2007) indicate that on average {approx}43% of residential buildings primary energy use is for space heating and cooling, vs. {approx}12% for water heating (about a 3.6:1 ratio). In contrast, for the particular prototype ZEH structures used in the analyses in this report, that ratio ranges from about 0.3:1 to 1.6:1 depending on location. The high-performance envelope of a ZEH results in much lower space heating and cooling loads relative to current housing and also makes the house sufficiently air-tight to require mechanical ventilation for indoor air quality. These envelope characteristics mean that the space conditioning load will be closer in size to the water heating load, which depends on occupant behavior and thus is not expected to drop by any significant amount because of an improved envelope. In some locations such as the Gulf Coast area, additional dehumidification will almost certainly be required during the shoulder and cooling seasons. In locales with heavy space heating needs, supplemental humidification may be needed because of health concerns or may be desired for improved occupant comfort. The U.S. Department of Energy (DOE) has determined that achieving their ZEH goal will require energy service equipment that can meet these needs while using 50% less energy than current equipment. One promising approach to meeting this requirement is through an integrated heat pump (IHP) - a single system based on heat pumping technology. The energy benefits of an IHP stem from the ability to utilize otherwise wasted energy; for example, heat rejected by the space cooling operation can be used for water heating. With the greater energy savings the cost of the more energy efficient components required for the IHP can be recovered more quickly than if they were applied to individual pieces of equipment to meet each individual energy service need. An IHP can be designed to use either outdoor air or geothermal resources (e.g., ground, ground water, surface water) as the environmental energy source/sink. Based on a scoping study of a wide variety of possible approaches to meeting the energy service needs for a ZEH, DOE selected the IHP concept as the most promising and has supported research directed toward the development of both air- and ground-source versions. This report describes the ground-source IHP (GS-IHP) design and includes the lessons learned and best practices revealed by the research and development (R&D) effort throughout. Salient features of the GS-IHP include a variable-speed rotary compressor incorporating a brushless direct current permanent magnet motor which provides all refrigerant compression, a variable-speed fan for the indoor section, a multiple-speed ground coil circuit pump, and a single-speed pump for water heating operation. Laboratory IHP testing has thus far used R-22 because of the availability of the needed components that use this refrigerant. It is expected that HFC R-410A will be used for any products arising from the IHP concept. Data for a variable-speed compressor that uses R-410A has been incorporated into the DOE/ORNL Mark VI Heat Pump Design Model (HPDM). HPDM was then linked to TRNSYS, a time-series-dependent simulation model capable of determining the energy use of building cooling and heating equipment as applied to a defined house on a sub-hourly basis. This provided a highly flexible design analysis capability for advanced heat pump equipment; however, the program also took a relatively long time to run. This approach was used with the initial prototype design reported in Murphy et al. (2007a) and in the business case analysis of Baxter (2007).

15 GEOTHERMAL ENERGY↗

Development of a Low Cost Heat Pump Water Heater - Second Prototype

Since the 1980s various attempts have been made to apply the efficiency of heat pumps to water heating. The products generated in the 80s and 90s were not successful, due in part to a lack of reliability and difficulties with installation and servicing. At the turn of the century, EnvironMaster International (EMI) produced a heat pump water heater (HPWH) based on a design developed by Arthur D. Little (ADL), with subsequent developmental assistance from Oak Ridge National Laboratory (ORNL) and ADL. This design was a drop-in replacement for conventional electric water heaters. In field and durability testing conducted by ORNL, it proved to be reliable and saved on average more than 50% of the energy used by the best conventional electric water heater. However, the retail price set by EMI was very high, and it failed in the market. ORNL was tasked to examine commercially available HPWH product technology and manufacturing processes for cost saving opportunities. Several cost saving opportunities were found. To verify the feasibility of these cost saving measures, ORNL completed a conceptual design for an HPWH based on an immersed condenser coil that could be directly inserted into a standard water tank through a sleeve affixed to one of the standard penetrations at the top of the tank. After some experimentation, a prototype unit was built with a double-wall coil inserted into the tank. When tested it achieved an energy factor (EF) of 2.12 to 2.2 using DOE-specified test procedures. A.O. Smith contacted ORNL in May 2006 expressing their interest in the ORNL design. The prototype unit was shipped to A.O. Smith to be tested in their laboratory. After they completed their test, ORNL analyzed the raw test data provided by A.O. Smith and calculated the EF to be approximately 1.92. The electric resistance heating elements of a conventional electric water heater are typically retained in a heat pump water heater to provide auxiliary heating capacity in periods of high demand. A.O. Smith informed us that when they applied electric resistance backup heating, using the criterion that resistance heat would be applied whenever the upper thermostat saw water temperatures below the heater s nominal setpoint of 135oF, they found that the EF dropped to approximately 1.5. This is an extremely conservative criterion for backup resistance heating. In a field test of the previously mentioned EMI heat pump water heater, residential consumers found satisfactory performance when the criterion for use of electric resistance backup heating was the upper temperature dropping below the set point minus 27 degrees. Applying this less conservative criterion to the raw data from the original A.O. Smith EF tests indicates that electric resistance heating would never have come on during the test, and thus the EF would have remained in the vicinity of 1.9. A.O. Smith expressed concern about having an EF below 2, as that value triggers certain tax advantages and would assist in their marketing of the product. We believe that insertion of additional length of tubing plus a less conservative set point for electric resistance backup heating would remedy this concern. However, as of this writing, A.O. Smith has not decided to proceed with a commercial product.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗