Search NASA⌕ Search

Engineering topics

Craig T Johansen

Publications and source records attributed to Craig T Johansen.

Nitric Oxide Laser-Induced Fluorescence Rotational Thermometry in a Hypersonic Non-Equilibrium Flow

Spatially-resolved nitric oxide (NO) planar laser-induced fluorescence (PLIF) rotational thermometry was performed on a Mach 5 non-equilibrium flow around a blunt-body specimen in the Hypersonic Materials Environmental Test System (HyMETS) arc-heat wind tunnel at the NASA Langley Research Center. Transitions within the (0,0) band in the A(exp⁡ 2)∑(sup⁡ +) - X(exp⁡ 2)Π system of NO were excited with a 10 Hz pulsed ultra-violet laser. A multi-line fitting algorithm was applied to the PLIF spectra and transitions were filtered based on an iterative method that maximizes thermometry accuracy. NO PLIF thermometry results are compared to non-equilibrium computational fluid dynamics (CFD) simulations reported in the literature. Differences between the experiment and CFD are quantified for the free-stream, post-shock, shear-layer, and expansion-fan regions of the flow. Potential sources of error, applicable to both the CFD and experiment, are discussed.

Connor C McDougall↗

TPSAS-NF1676L-30534-DND

Explore the source record for details and available documents.

Connor C McDougall↗

Analysis of the Amplitude Response of a Two-Point and a Two-Line/Multi-Point Focused Laser Differential Interferometer

Experiments were performed with two different focused laser differential interferometer (FLDI) instruments to assess the amplitude response of each instrument to a traveling shock-wave generated by a laser spark. The first FLDI instrument generated two measurement points, with each measurement point providing sensitivity to density fluctuations induced by the shockwave. By performing a cross-correlation between the signals obtained from each measurement point, the phase velocity of density fluctuations can be obtained. The second FLDI instrument generated two measurement lines that are oriented either parallel or orthogonal to the shockwave direction of travel with the resulting interference pattern sampled at multiple equally-spaced points along each line. As a result, this instrument provides density fluctuation measurement capability at multiple points simultaneously. When the measurement lines are oriented parallel to the shockwave direction of travel, the phase velocity, rate of change of the phase velocity, and acceleration of density fluctuations traveling along each line can be obtained by performing a cross-correlation between points along a single line. When the measurement lines are oriented orthogonal to the shockwave direction of travel, the spatially-varying phase velocity can be obtained by performing a cross-correlation between points at the same relative location on each measurement line. Computations of the shockwave generated by the laser spark are used to simulate the response of each instrument and are compared to the experimental results. High-speed Schlieren imaging has also been performed and is compared with the FLDI measurements and computational results.

Focused Laser Differential Interferometer↗