Search NASASearch

Engineering topics

Craig, J. E.

Publications and source records attributed to Craig, J. E..

Visualization of flows in a motored rotary combustion engine using holographic interferometry

The use of holographic interferometry to view the small- and large-scale flow field structures in the combustion chamber of a motored Wankel engine assembly is described. In order that the flow patterns of interest could be observed, small quantities of helium were injected with the intake air. Variation of the air flow patterns with engine speed, helium flow rate, and rotor position are described. The air flow at two locations within the combustion chamber was examined using this technique.

Hicks, Y. R.

Laser diagnostic methods - A summary

This is a summary and discussion of the state of the art in the use of laser diagnostics in fluid and plasma dynamics. This will encompass: interferometry, scattering, spectroscopy, and velocimetry. Examples of such applications will be provided in the area of fluid dynamics of particle generation and breakup, analysis of three-dimensional density fields, and applications in combustion.

Trolinger, J. D.

Feasibility study of three-dimensional holographic interferometry for aerodynamics

Laser holographic interferometry was tried as a nonintrusive diagnostic tool for studying unsteady two dimensional flows. A NACA 0012 airfoil was tested, while undergoing dynamic stall, over a range of Mach numbers of 0.3 to 0.5, Reynolds number of 0.5 x 10 to the 6th power to 2 x 10 to the 6th power, and at reduced frequencies of 0.015 to 0.15. It was found that both quantitative and qualitative data could be obtained by the technique. Surface pressures on the airfoil can be measured to within 1% of those measured with orifices and pressure transducers when the flow is attached. Velocity profiles were measured near the wake region, and they compared very well with laser velocimeter data for attached flows. For separated flows with large scale vortices, densities can be measured, but pressures and velocities cannot be deduced with the assumption of constant pressure gradient in the normal direction. The sensitivity of the interferograms was good at a Mach number of 0.4 and a Reynolds number of 4 x 10 to the 6th power/ft; the sensitivity worsened at smaller Mach numbers and Reynolds numbers, and improved at larger ones.

Craig, J. E.

Laser holographic interferometry for an unsteady airfoil in dynamic stall

Laser holographic interferometry was used to study a two-dimensional NACA 0012 airfoil undergoing dynamic stall. The airfoil, fabricated from graphite fiber and epoxy, was tested at Mach numbers of 0.3 to 0.6, at Reynolds numbers of 500,000-2,000,000, at reduced frequencies of 0.015 to 0.15, and at mean angles of attack of 0-10 deg with amplitudes of 10 deg. Density and pressure fields were obtained from dual-plate interferograms. Double-pulse interferograms, which seemed to show the wake boundaries better, were also taken. Comparisons of pressures with orifice pressures were good for the attached flow cases. For the separated flow cases, which had a vortex enbedded in the flow, the comparisons were poor. Vortices, wake structures, and the dynamic stall process can be seen by holographic interferometry.

Lee, G.

Nd:YAG holographic interferometer for aerodynamic research

A holographic interferometer system has been installed in the NASA Ames 2- by 2-Foot Transonic Wind Tunnel. The system incorporates a modern 10 pps, Nd:YAG pulsed laser which provides reliable operation and is easy to align. The spatial filtering requirements of the unstable resonator beam are described, as well as the integration of the system into the existing schlieren system. A two-plate holographic interferometer is used to reconstruct flow field data. For static wind tunnel models, the single exposure holograms are recorded in the usual manner; however, for dynamic models such as oscillating airfoils, synchronous laser hologram recording is used.

Craig, J. E.

Operating manual holographic interferometry system for 2 x 2 foot transonic wind tunnel

A holographic interferometer system was installed in a 2X2 foot transonic wind tunnel. The system incorporates a modern, 10 pps, Nd:YAG pulsed laser which provides reliable operation and is easy to align. The spatial filtering requirements of the unstable resonator beam are described as well as the integration of the system into the existing Schieren system. A two plate holographic interferometer is used to reconstruct flow field data. For static wind tunnel models the single exposure holograms are recorded in the usual manner; however, for dynamic models such as oscillating airfoils, synchronous laser hologram recording is used.

Craig, J. E.