Search NASA⌕ Search

Engineering topics

Crepeau, J C

Publications and source records attributed to Crepeau, J C.

HIGH TEMPERATURE THERMAL AND STRUCTURAL MATERIAL PROPERTIES FOR METALS USED IN LWR VESSELS

Because of the impact that melt relocation and vessel failure may have on subsequent progression and associated consequences of a Light Water Reactor (LWR) accident, it is important to accurately predict heating and relocation of materials within the reactor vessel, heat transfer to and from the reactor vessel, and the potential for failure of the vessel and structures within it. Accurate predictions of such phenomena require high temperature thermal and structural properties. However, a review of vessel and structural steel material properties used in severe accident analysis codes reveals that the required high temperature material properties are extrapolated with little, if any, data above 1000 K. To reduce uncertainties in predictions relying upon extrapolated high temperature data, Idaho National Laboratory (INL) obtained high data for two metals used in LWR vessels: SA 533 Grade B, Class 1 (SA533B1) low alloy steel, which is used to fabricate most US LWR reactor vessels; and Type 304 Stainless Steel SS304, which is used in LWR vessel piping, penetration tubes, and internal structures. This paper summarizes the new data, and compares it to existing data.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Extension Wire for High Temperature Irradiation Resistant Thermocouples

In an effort to reduce production costs for the doped molybdenum/niobium alloy High Temperature Irradiation Resistant Thermocouples (HTIR-TCs) recently developed by the Idaho National Laboratory (INL), a series of evaluations were completed to identify an optimum compensating extension cable. Results indicate that of those combinations tested, two inexpensive, commercially-available copper nickel alloy wires approximate the low temperature (0 to 500oC) thermoelectric output of KW-Mo versus Nb-1%Zr in HTIR-TCs. For lower temperatures (0 to 150oC), which is the region where soft extension cable is most often used, results indicate that the thermocouple emf is best replicated by the Cu-3.5%Ni versus Cu-5%Ni combination (measured emfs were within 4% at 100 and 150oC). At higher temperatures (300 to 500oC), data suggest that the Cu-5%Ni versus Cu-10%Ni combination may yield data closer to that obtained with KW-Mo versus Nb-1%Zr wires (measured emfs were within 8%). Further, interpolation of test results suggest that a combination containing a negative thermoelement with slightly lower nickel content, such as Cu-5%Ni versus Cu-9%Ni, may yield more representative data if extension cable is needed for these higher temperatures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Enhancements to High Temperature In-Pile Thermocouple Performance

A joint University of Idaho (UI) and Idaho National Laboratory (INL) University Nuclear Research Initiative (UNERI) was to initiated to extend initial INL efforts to develop doped molybdenum/niobium alloy High Temperature Irradiation Resistant Thermocouples (HTIR-TCs). The overall objective of this UNERI was to develop recommendations for an optimized thermocouple design for high temperature, long duration, in-pile testing by expanding upon results from initial INL efforts. Tasks to quantify the impact of candidate enhancements, such as alternate alloys, alternate geometries, and alternate thermocouple fabrication techniques, on thermocouple performance were completed at INL's High Temperature Test Laboratory (HTTL), a state of the art facility equipped with specialized equipment and trained staff in the area of high temperature instrumentation development and evaluation. Key results of these evaluations, which are documented in this report, are as follows. The doped molybdenum and Nb-1%Zr, which were proposed in the initial INL HTIR-TC design, were found to retain ductility better than the developmental molybdenum-low niobium alloys and the niobium-low molybdenum alloys evaluated. Hence, the performance and lower cost of the commercially available KW-Mo makes a thermocouple containing KW-Mo and Nb-1%Zr the best option at this time. HTIR-TCs containing larger diameter wires offer the potential to increase HTIR-TC stability and reliability at higher temperatures. HTIR-TC heat treatment temperatures and times should be limited to not more than 100 C above the proposed operating temperatures and to durations of at least 4 to 5 hours. Preliminary investigations suggest that the performance of swaged and loose assembly HTIR-TC designs is similar. However, the swaged designs are less expensive and easier to construct. In addition to optimizing HTIR-TC performance, This UNERI project provided unique opportunities to several University of Idaho students, allowing them to become familiar with the techniques and equipment used for specialized high temperature instrumentation fabrication and evaluation and to author/coauthor several key conference papers and journal articles.

36 MATERIALS SCIENCE↗

Viability of Pushrod Dilatometry Techniques for High Temperature In-Pile Measurements

To evaluate the performance of new fuel, cladding, and structural materials for use in advanced and existing nuclear reactors, robust instrumentation is needed. Changes in material deformation are typically evaluated out-of-pile, where properties of materials are measured after samples were irradiated for a specified length of time. To address this problem, a series of tests were performed to examine the viability of using pushrod dilatometer techniques for in-pile instrumentation to measure deformation. The tests were performed in three phases. First, familiarity was gained in the use and accuracy of this system by testing samples with well defined thermal elongation characteristics. Second, high temperature data for steels, specifically SA533 Grade B, Class 1 (SA533B1) Low Alloy Steel and Stainless Steel 304 (SS304), found in Light Water Reactor (LWR) vessels, were aquired. Finally, data were obtained from a short pushrod in a horizontal geometry to data obtained from a longer pushrod in a vertical geometry, the configuration likely to be used for in-situ measurements. Results of testing show that previously accepted data for the structural steels tested, SA533B1 and SS304, are inaccurate at high temperatures (above 500 oC) due to extrpolation of high temperature data. This is especially true for SA533B1, as previous data do not account for the phase transformation of the material between 730 oC and 830 oC. Also, comparison of results for horizontal and vertical configurations show a maximum percent difference of 2.02% for high temperature data.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Enhancements to High Temperature In-Pile Thermocouple Performance

A joint University of Idaho (UI) and Idaho National Laboratory (INL) University Nuclear Research Initiative (UNERI) was to initiated to extend initial INL efforts to develop doped lybdenum/niobium alloy High Temperature Irradiation Resistant Thermocouples (HTIR-TCs). The overall objective of this UNERI was to develop recommendations for an optimized thermocouple design for high temperature, long duration, in-pile testing by expanding upon results from initial INL efforts. Tasks to quantify the impact of candidate enhancements, such as alternate alloys, alternate geometries, and alternate thermocouple fabrication techniques, on thermocouple performance were completed at INL's High Temperature Test Laboratory (HTTL), a state of the art facility equipped with specialized equipment and trained staff in the area of high temperature instrumentation development and evaluation. Key results of these evaluations, which are documented in this report, are as follows. The doped molybdenum and Nb-1%Zr, which were proposed in the initial INL HTIR-TC design, were found to retain ductility better than the developmental molybdenum-low niobium alloys and the niobium-low molybdenum alloys evaluated. Hence, the performance and lower cost of the commercially available KW-Mo makes a thermocouple containing KW-Mo and Nb-1%Zr the best option at this time. HTIR-TCs containing larger diameter wires offer the potential to increase HTIR-TC stability and reliability at higher temperatures. HTIR-TC heat treatment temperatures and times should be limited to not more than 100 °C above the proposed operating temperatures and to durations of at least 4 to 5 hours. Preliminary investigations suggest that the performance of swaged and loose assembly HTIR-TC designs is similar. However, the swaged designs are less expensive and easier to construct. In addition to optimizing HTIR-TC performance, This UNERI project provided unique opportunities to several University of Idaho students, allowing them to become familiar with the techniques and equipment used for specialized high temperature instrumentation fabrication and evaluation and to author/coauthor several key conference papers and journal articles.

99 GENERAL AND MISCELLANEOUS↗

HTIR-TC Compensating Extension Wire Evaluations

In an effort to reduce production costs for the doped molybdenum/niobium alloy High Temperature Irradiation Resistant Thermocouples (HTIR-TCs) recently developed by the Idaho National Laboratory, a series of evaluations were completed to identify an optimum compensating extension cable. As documented in this report, results indicate that of those combinations tested, two inexpensive, commercially-available copper nickel alloy wires approximate the low temperature (0 to 500 °C) thermoelectric output of KW-Mo (molybdenum doped with tungsten and potassium silicate) versus Nb-1%Zr in HTIR-TCs. For lower temperatures (0 to 150 °C), which is the region where soft extension cable is most often located, results indicate that the thermocouple emf is best replicated by the Cu-3.5%Ni versus Cu-5%Ni combination (measured emfs were within 4% at 100 and 150 °C). At higher temperatures (300 to 500 °C), data suggest that the Cu-5%Ni versus Cu-10%Ni combination may yield data closer to that obtained with KWMo versus Nb-1%Zr wires (measured emfs were within 8%).

36 MATERIALS SCIENCE↗