Search NASA⌕ Search

Engineering topics

Creux, Patrice

Publications and source records attributed to Creux, Patrice.

Evaluation of Electron Tomography Capabilities for Shale Imaging

Despite the advantageous resolution of electron tomography (ET), reconstruction of three-dimensional (3D) images from multiple two-dimensional (2D) projections presents several challenges, including small signal-to-noise ratios, and a limited projection range. This study evaluates the capabilities of ET for thin sections of shale, a complex nanoporous medium. A numerical phantom with 1.24 nm pixel size is constructed based on the tomographic reconstruction of a Barnett shale. A dataset of 2D projection images is numerically generated from the 3D phantom and studied over a range of conditions. First, common reconstruction techniques are used to reconstruct the shale structure. The reconstruction uncertainty is quantified by comparing overall values of storage and transport metrics, as well as the misclassification of pore voxels compared to the phantom. We then select the most robust reconstruction technique and we vary the acquisition conditions to quantify the effect of artifacts. We find a strong agreement for large pores over the different acquisition workflows, while a wider variability exists for nanometer-scale features. Furthermore, the limited projection range and reconstruction are identified as the main experimental bottlenecks, thereby suggesting that sample thinning, advanced holders, and advanced reconstruction algorithms offer opportunities for improvement.

3D scanning transmission electron microscopy↗

Influence of Standard Image Processing of 3D X-ray Microscopy on Morphology, Topology and Effective Properties

Estimating porous media properties is a vital component of geosciences and the physics of porous media. Until now, imaging techniques have focused on methodologies to match image-derived flows or geomechanical parameters with experimentally identified values. Less emphasis has been placed on the compromise between image processing techniques and the consequences on topological and morphological characteristics and on computed properties such as permeability. The effects of some of the most popular image processing techniques (filtering and segmentation) available in open source on 3D X-ray Microscopy (micro-XRM) images are qualitatively and quantitatively discussed. We observe the impacts of various filters such as erosion-dilation and compare the efficiency of Otsu’s method of thresholding and the machine-learning-based software Ilastik for segmentation.

58 GEOSCIENCES↗

Reconstructing porous media using generative flow networks

One area of intense scientific interest for the study of sandstones, carbonates, and shale at the pore scale is the use of limited image and petrophysical data to generate multiple realizations of a rock’s pore structure. Such images aid efforts to quantify uncertainty in petrophysical properties, including porosity–permeability transforms. We develop and evaluate a deep learning-based method to synthesize porous media volumes using a so-called generative flow model trained on x-ray microscope images of rock texture and pore structure. These models are optimized on a log-likelihood objective and they synthesize large and realistic three-dimensional images. Further, we demonstrate the rapid generation of sandstone image volumes that display realism as gauged by quantitative comparison of topological features using Minkowski functionals of porosity, specific surface area, and the Euler–Poincaré characteristic (i.e., pore connectivity). We also evaluate the single-phase permeability using Navier–Stokes and lattice Boltzmann methods and show that transport properties of the generated samples match measured trends.

58 GEOSCIENCES↗

A new mini-triaxial cell for combined high-pressure and high-temperature in situ synchrotron X-ray microtomography experiments up to 400°C and 24 MPa

A new experimental triaxial cell for in situ synchrotron X-ray micro-computed tomography aimed at imaging small samples of (6 mm × 19 mm) at high temperatures (up to 400°C) and pressures (up to 24 MPa confining) is presented. The system has flow-through capabilities, independent axial and radial pressure control, and has been developed and tested at the 8.3.2. beamline at the Advanced Light Source. The characteristics of this new experimental rig are described, along with the challenges, mainly concerning the combination of X-ray transparency with vessel strength at high temperature, and solutions found during the development stage. An experiment involving oil shale pyrolysis under subsurface conditions, highlighting the importance of a device able to operate in this pressure and temperature range, is also introduced. Furthermore, the availability of this cell enables an unprecedented range of experiments in the Earth Sciences, with a special focus on subsurface geothermal processes.

47 OTHER INSTRUMENTATION↗