Crocker, Robert W.

Publications and source records attributed to Crocker, Robert W..

V31 Test Report

The V31 containment vessel was procured by the US Army Recovered Chemical Materiel Directorate (RCMD) as a third-generation EDS containment vessel. It is the fifth EDS vessel to be fabricated under Code Case 2564 of the 2019 ASME Boiler and Pressure Vessel Code, which provides rules for the design of impulsively loaded vessels. The explosive rating for the vessel, based on the code case, is twenty-four (24) pounds TNT-equivalent for up to 1092 detonations. This report documents the results of explosive tests that were performed on the vessel at Sandia National Laboratories in Albuquerque, New Mexico to qualify the vessel for field operations use. There were three design basis configurations for qualification testing. Qualification test (1) consisted of a simulated M55 rocket motor and warhead assembly of 24lbs of Composition C-4 (30 lb TNT equivalent). This test was considered the maximum load case, based on modeling and simulation methods performed by Sandia prior to the vessel design phase. Qualification test (2) consisted of a regular, right circular cylinder, unitary charge, located central to the vessel interior of 19.2 lb of Composition C-4 (24 lb TNT equivalent). Qualification test (3) consisted of a 12-pack of regular, right circular cylinders of 2 lb each, distributed evenly inside the vessel (totaling 19.2 lb of C-4, or 24 lb TNT equivalent). All vessel acceptance criteria were met .

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

V31 Test Report

The V31 containment vessel was procured by the US Army Recovered Chemical Material Directorate (RCMD) as a third - generation EDS containment vessel. It is the fifth EDS vessel to be fabricated under Code Case 2564 of the 2019 ASME Boiler and Pressure Vessel Code, which provides rules for the design of impulsively loaded vessels. The explosive rating for the vessel, based on the code case, is twenty-four (24) pounds TNT - equivalent for up to 1092 detonations. This report documents the results of explosive tests that were performed on the vessel at Sandia National Laboratories in Albuquerque, New Mexico to qualify the vessel for field operations use. There were three design basis configurations for qualification testing. Qualification test (1) consisted of a simulated M55 rocket motor and warhead assembly of 24lbs of Composition C-4 (30 lb TNT equivalent). This test was considered the maximum load case, based on modeling and simulation methods performed by Sandia prior to the vessel design phase. Qualification test (2) consisted of a regular, right circular cylinder, unitary charge, located central to the vessel interior of 19.2 lb of Composition C-4 (24 lb TNT equivalent). Qualification test (3) consisted of a 12-pack of regular, right circular cylinders of 2 lb each, distributed evenly inside the vessel (totaling 19.2 lb of C-4, or 24 lb TNT equivalent). All vessel acceptance criteria were met.

42 ENGINEERING↗

Preliminary EDS Liquid Sample Adapter Design Assurance Testing

A new liquid sample adapter design for the Explosive Destruction Systems has been developed. The design features a semi-transparent fluoropolymer tube coupled to the vessel high pressure sample valve with a closing quick connect fitting. The sample tubes are the pressure-limiting component. The tubes were hydrostatically tested to establish failure characteristics and pressure limits at ambient and operational temperatures. A group of tubes from two manufacturing lots were tested to determine the consistency of the commercial part. An upper pressure limit was determined for typical operations.

42 ENGINEERING↗

Phosgene Neutralization Chemistry for the Explosive Destruction System (EDS)

This report summarizes activities at Sandia National Laboratories as part of the Explosive Destruction System (EDS) Phase 3 (P3) System design. An exploration of chemical neutralization strategies of phosgene was conducted for safe disposal of recovered mortars and M79 1000 lb. bombs filled with carbonyl dichloride "phosgene" or "CG agent" (molecular formula = COCl 2 ). The incumbent strategy utilized aqueous sodium hydroxide was found to be the worst-case scenario, producing enough CO 2 gas that would cause an unacceptable pressure and temperature spike. Several chemical neutralization strategies were evaluated based on criteria set by the operating envelope of the P3 design. In the end, it was determined that a pure solution of N-methyl ethanolamine (MeEA) or 90% monoethanolamine (MEA)(aqueous) provided the best balance reaction profile, cost, and safety.

36 MATERIALS SCIENCE↗

V28 Test Report

The V28 containment vessel was procured by the US Army Recovered Chemical Material Directorate (RCMD) as a replacement vessel for use on the P2 Explosive Destruction Systems. It is the fourth EDS vessel to be fabricated under Code Case 2564 of the ASME Boiler and Pressure Vessel Code, which provides rules for the design of impulsively loaded vessels. The explosive rating for the vessel, based on the Code Case, is nine (9) pounds TNT- equivalent for up to 637 detonations. This report documents the results of explosive tests that were done on the vessel at Sandia National Laboratories in Albuquerque New Mexico to qualify the vessel for explosive use. The primary qualification test consisted of six, 1.5 pounds charges of Composition C-4 (equivalent to 11.25 pounds TNT) distributed around the vessel in accordance with the User Design Specification. This test was repeated due to a lack of proper clamp settings. Two additional tests using less explosive were performed, one identical in configuration to a test performed in the V27 qualification series as a baseline for comparison, and one where the separation distance of the charges was increased to extend the V27 analysis of distributed load effects on the P2 vessel. All vessel acceptance criteria were met.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

EDS V26 Vessel Clamp Explosive Test Report

This report documents the results of explosive re-qualification tests of the EDS V26 Vessel that were conducted at Sandia National Laboratories in Albuquerque, New Mexico in May 2015 following the retrofitting of the vessel with a three piece clamp for use on the P2A system. The V26 containment vessel is the second EDS vessel to be fabricated under Code Case 2564 of the ASME Boiler and Pressure Vessel Code, which provides rules for the design of impulsively loaded vessels. The explosive rating for the vessel, based on the code case, is nine (9) pounds TNT-equivalent for up to 637 detonations. The goals of the tests were to qualify the vessel, particularly the clamping system, for explosive use. The explosive tests consisted of a 9 pound bare charge of Composition C-4 (equivalent to 11.25 pounds TNT), followed by a 7.2 pound bare charge of Composition C-4 (equivalent to 9 pounds of TNT). Helium permeation measurements of the seal and strain measurements using a pi tape and strain gauges were made. All vessel acceptance criteria were met.

36 MATERIALS SCIENCE↗

V27 Test Report.

The V27 containment vessel was procured by the US Army Recovered Chemical Material Directorate ( RCMD ) as a replacement vessel for use on the P2 Explosive Destruction Systems. It is the third EDS vessel to be fabricated under Code Case 2564 of the ASME Boiler and Pressure Vessel Code, which provides rules for the design of impulsively loaded vessels. The explosive rating for the vessel, based on the Code Case, is nine (9) pounds TNT - equivalent for up to 637 detonations . This report documents the results of explosive tests that were done on the vessel at Sandia National Laboratories in Albuquerque New Mexico to qualify the vessel for explosive use . The primary qualification test consisted of si x 1.5 pound charges of Composition C - 4 (equivalent to 11.25 pounds TNT) distributed around the vessel in accordance with the User Design Specification. Four subsequent tests using less explosive evaluated the effects of slight variations in orientation of the charges . All vessel acceptance criteria were met.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

EDS V26 Containment Vessel Explosive Qualification Test Report

The objective of the test was to qualify the vessel for its intended use by subjecting it to a 1.25 times overtest. The criteria for success are that the measured strains do not exceed the calculated strains from the vessel analysis, there is no significant additional plastic strain on subsequent tests at the rated design load (shakedown), and there is no significant damage to the vessel and attached hardware that affect form, fit, or function. Testing of the V25 Vessel in 2011 established a precedent for testing V26 [2]. As with V25, two tests were performed to satisfy this objective. The first test used 9 pounds of Composition C-4 (11.25 lbs. TNT-equivalent), which is 125 percent of the design basis load. The second test used 7.2 pounds of Composition C-4 (9 lbs. TNT-equivalent) which is 100 percent of the design basis load. The first test provided the required overtest while the second test served to demonstrate shakedown and the absence of additional plastic deformation. Unlike the V25 vessel, which was mounted in a shipping cradle during testing, the V26 vessel was mounted on the EDS P2U3 trailer prior to testing. Visual inspections of the EDS vessel, surroundings, and diagnostics were completed before and after each test event. This visual inspection included analyzing the seals, fittings, and interior surfaces of the EDS vessel and documenting any abnormalities or damages. Photographs were used to visually document vessel conditions and findings before and after each test event.

36 MATERIALS SCIENCE↗

Magneto-hydrodynamic detection of vortex shedding for molten salt flow sensing.

High temperature flow sensors must be developed for use with molten salts systems at temperatures in excess of 600ÀC. A novel magneto-hydrodynamic sensing approach was investigated. A prototype sensor was developed and tested in an aqueous sodium chloride solution as a surrogate for molten salt. Despite that the electrical conductivity was a factor of three less than molten salts, it was found that the electrical conductivity of an electrolyte was too low to adequately resolve the signal amidst surrounding noise. This sensor concept is expected to work well with any liquid metal application, as the generated magnetic field scales proportionately with electrical conductivity.

Kruizenga, Alan Michael↗