Search NASA⌕ Search

Engineering topics

Croft, Stephen

Publications and source records attributed to Croft, Stephen.

At least 55 records · Page 3

Using the JCC-71 neutron coincidence collar as a benchmark for detector characterization with PTR-32 list mode data acquisition

Augmenting or interchanging current international safeguards shift registerbased data acquisition systems with list mode data acquisition systems gives nondestructive assay (NDA) systems greater versatility. Neutron list mode data analysis offers comparable analytical results to the more widely used shift register analysis in nuclear material quantification applications and offers several diagnostic tools that are specifically beneficial to in-laboratory characterization and calibration measurements. These benefits include identification of non-ideal behavior, optimization of operational parameters from a single measurement, and an improved understanding of the physics-based behavior of NDA systems for a more precise system representation and more confident assay results. In this work the advantages of using list mode data acquisition for detector characterization are demonstrated experimentally. Two commercial-off-the-shelf International Atomic Energy Agency-supported technologies are used for a typical detector characterization procedure and their performance is compared. Specifically, a 3 He-based Canberra Industries JCC-71 Neutron Coincidence Collar is characterized using the Hungarian Institute of Isotopes’ Pulse Train Recorder-32 (PTR-32) list mode data acquisition system, and the results are compared to those obtained using the standard Canberra Industries JSR-15 model shift register. The quantitative results from the two systems are in agreement, which demonstrates that the PTR-32 is a technically viable alternative to conventional shift register electronics for this task. A suitable procedure for full instrument characterization is described, and the added benefits of list mode for characterization and data collection are discussed. Furthermore, this is an important step toward establishing a procedure for the routine use of list mode data acquisition and analysis for neutron NDA system characterization in safeguards field applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Determining 235 U enrichment in bulk uranium items using dual-energy interrogation with delayed neutron measurement

Bulk uranium items are often measured using active neutron interrogation systems to take advantage of the relatively high penetrability of neutrons, providing the ability to measure uranium mass in large, dense configurations. Because the emitted neutrons from 235 U and 238 U in such configurations are, for all practical purposes, indistinguishable, established active measurement techniques require many representative calibration standards and/or well-known isotopic information to interpret the assay results (i.e., extract an isotopic mass from the effective mass). Here, the primary objective of this work is to investigate the ability of a dual-energy neutron interrogation technique to estimate uranium enrichment for bulk materials, which has the potential to eliminate the need for a (traditionally separate) gamma isotopic measurement. Dual neutron interrogation energies were achieved by adding a deuterium–tritium (D–T) neutron generator into the measurement chamber of the Oak Ridge National Laboratory 252 Cf Shuffler. This new technique exploits the change in fission rates as a function of interrogating neutron energy to independently determine the 235 U and 238 U content in the measurement item. Results from traditional 252 Cf measurements and the new D–T measurements were then used to develop a relationship between uranium enrichment and the ratio of the two delayed neutron count rates. Lastly, technical feasibility is successfully demonstrated using the modified 252 Cf Shuffler as a test bed, although several areas where refinements are both possible and needed before DEANI can be deployed as an analytical tool to meet specific measurement goals are identified.

252cf shuffler↗

High-Resolution Gamma Spectrometry Data Set for High Burnup Pressurized Water Reactor Used Fuel

Over the past decade, considerable resources have been applied to investigate verification of used nuclear fuel assemblies for international safeguards. The opportunity to expand the available data used to validate these verification techniques was presented in 2016 by the High Burnup Spent Fuel Data Project, which made 25 high-burnup pressurized water reactor used fuel rods available for measurement in the Irradiated Fuels Examination Laboratory at Oak Ridge National Laboratory. With the support of the National Nuclear Security Administration Office of Nonproliferation and Arms Control, a 2017 campaign measured the 25 used fuel rods with a high-resolution gamma spectrometer. A planar high-purity germanium detector was used to provide high-efficiency across an energy range from 60 keV to 3 MeV. Gamma spectra of individual fuel rods were collected in 4.5 mm steps along the entire length of each rod. In addition, spectra were collected on select rods in rotational increments of 30 degrees to provide data on the distribution of fission products along the rod perimeter. The spectra are stored on a controlled-access website for use by others. This paper describes the measurement geometry, used fuel rod characteristics, example spectra, and preliminary analyses performed during the measurement campaign.

Smith, Susan↗

Advanced Neutron Counting Electronics Designed and Implemented on the JCC-71 Neutron Coincidence Collar to Replace Standard JAB-01 Preamplifier/Amplifier/Discriminator Boards

New in-house neutron counting electronics were designed and built at Oak Ridge National Laboratory to replace the Canberra Industries JAB-01 preamplifier/amplifier/discriminator boards on their JCC-71 Neutron Coincidence Collar model system. The new electronics include a preamplifier and motherboard design, which fit inside the footprint of the existing junction box, as well as an external “ORNL Neutron Collar Processor” board. The goal of the new electronics is to provide the same neutron processing functionalities as the JAB-01 boards and extend the capabilities of the JCC-71 system by placing a preamplifier on each of the 18 3He tubes to facilitate neutron list mode data acquisition. Each 3He tube is then capable of producing an individual signal output to be analyzed using a list mode data acquisition system such as the PTR-32 or N2000. List mode data analysis provides the opportunity to use all 18 signal channels to produce a spatial response matrix to assay fresh nuclear fuel assemblies. This paper describes the development of the new electronics and provides performance comparison measurements between the two electronics board systems using list mode data acquisition.

Moore, Angela↗

High-resolution Gamma Spectroscopy Measurements of Pressurized Water Reactor Spent Nuclear Fuel Rods

International nuclear safeguards use nondestructive assay techniques to verify declared characteristics of spent nuclear fuel (SNF) assemblies. The declared characteristics usually include the initial enrichment, assembly average burnup, and irradiation history. The primary nondestructive assay tool used by the International Atomic Energy Agency has been the fork detector irradiated fuel measurement system, which uses gross gamma and neutron correlations; however, there have been several research publications within the last decade on the use of high-resolution gamma spectroscopy for the determination of SNF characteristics. References [1]–[6] are published journal articles on this subject from 2006–2016. This report describes measurements of 25 individual SNF rods using high-resolution gamma spectroscopy. Details of the measurement geometry, measurement settings, and rod characteristics are documented. These spectra are intended for the validation of simulation codes that calculate SNF inventory and source term characteristics. The spectrum archive is available to evaluate future spectrum analysis methods. The archive contains full axial scan spectra of each SNF rod. This allows more detailed comparison between simulation and nondestructive analysis than is possible on assemblies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of a Boron-Coated-Straw-Based HLNCC for International Safeguards Applications

3He gas has been used in various scientific and security applications for decades, but it is now in short supply. Alternatives to 3He detectors are currently being integrated and tested in neutron coincidence counter designs, of a type which are widely used in nuclear safeguards for nuclear materials assay. A boron-coated-straw-based design, similar to the High-Level Neutron Coincidence Counter-II, was built by Proportional Technologies Inc., and has been tested by the Oak Ridge National Laboratory (ORNL) at both the JRC in Ispra and ORNL. Characterization measurements, along with nondestructive assays of various plutonium samples, have been conducted to determine the performance of this coincidence counter replacement in comparison with other similar counters. This paper presents results of these measurements.

Moore, Angela↗

OR14-V-Uncertainty-PD2La Uncertainty Quantification for Nuclear Safeguards and Nondestructive Assay Final Report

The various methods of nondestructive assay (NDA) of special nuclear material (SNM) have applications in nuclear nonproliferation, including detection and identification of illicit SNM at border crossings and quantifying SNM at nuclear facilities for safeguards. No assay method is complete without “error bars,” which provide one way of expressing confidence in the assay result. Consequently, NDA specialists typically provide error bars and also partition total uncertainty into “random” and “systematic” components so that, for example, an error bar can be developed for the total mass estimate in multiple items. Uncertainty Quantification (UQ) for NDA has always been important, but it is recognized that greater rigor is needed and achievable using modern statistical methods.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Extension of the Dytlewski-style dead time correction formalism for neutron multiplicity counting to any order

Here, neutron multiplicity counting using shift-register calculus is an established technique in the science of international nuclear safeguards for the identification, verification, and assay of special nuclear materials. Typically passive counting is used for Pu and mixed Pu-U items and active methods are used for U materials. Three measured counting rates, singles, doubles and triples are measured and, in combination with a simple analytical point-model, are used to calculate characteristics of the measurement item in terms of known detector and nuclear parameters. However, the measurement problem usually involves more than three quantities of interest, but even in cases where the next higher order count rate, quads, is statistically viable, it is not quantitatively applied because corrections for dead time losses are currently not available in the predominant analysis paradigm. In this work we overcome this limitation by extending the commonly used dead time correction method, developed by Dytlewski, to quads. We also give results for pents, which may be of interest for certain special investigations. Extension to still higher orders, may be accomplished by inspection based on the sequence presented. We discuss the foundations of the Dytlewski method, give limiting cases, and highlight the opportunities and implications that these new results expose. In particular there exist a number of ways in which the new results may be combined with other approaches to extract the correlated rates, and this leads to various practical implementations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

OR14-V-Uncertainty-PD2La Uncertainty Quantification Workshop Report

The Uncertainty Quantification (UQ) research team held the Uncertainty Quantification for Nondestructive Assay Workshop as part of the Advances in Nuclear Nonproliferation Technology & Policy Conference held in Santa Fe, New Mexico, on September 28–30, 2016. The workshop had 14 speakers, each of whom submitted a paper for publication in the conference proceedings. They gave lectures in the mornings and participated in discussions in the afternoons. Forty-three people from the national laboratories, industry, and academia attended the workshop. Their research interests ranged from uncertainties in nuclear data to uncertainties in human reliability.

97 MATHEMATICS AND COMPUTING↗

Estimating the Effective System Dead Time Parameter for Correlated Neutron Counting

We present that neutron time correlation analysis is one of the main technical nuclear safeguards techniques used to verify declarations of, or to independently assay, special nuclear materials. Quantitative information is generally extracted from the neutron-event pulse train, collected from moderated assemblies of 3 He proportional counters, in the form of correlated count rates that are derived from event-triggered coincidence gates. These count rates, most commonly referred to as singles, doubles and triples rates etc., when extracted using shift-register autocorrelation logic, are related to the reduced factorial moments of the time correlated clusters of neutrons emerging from the measurement items. Correcting these various rates for dead time losses has received considerable attention recently. The dead time losses for the higher moments in particular, and especially for large mass (high rate and highly multiplying) items, can be significant. Consequently, even in thoughtfully designed systems, accurate dead time treatments are needed if biased mass determinations are to be avoided. In support of this effort, in this paper we discuss a new approach to experimentally estimate the effective system dead time of neutron coincidence counting systems. It involves counting a random neutron source (e.g. AmLi is a good approximation to a source without correlated emission) and relating the second and higher moments of the neutron number distribution recorded in random triggered interrogation coincidence gates to the effective value of dead time parameter. We develop the theoretical basis of the method and apply it to the Oak Ridge Large Volume Active Well Coincidence Counter using sealed AmLi radionuclide neutron sources and standard multiplicity shift register electronics. The method is simple to apply compared to the predominant present approach which involves using a set of 252 Cf sources of wide emission rate, it gives excellent precision in a conveniently short time, and it yields consistent results as a function of the order of the moment used to extract the dead time parameter. In addition, this latter observation is reassuring in that it suggests the assumptions underpinning the theoretical analysis are fit for practical application purposes. However, we found that the effective dead time parameter obtained is not constant, as might be expected for a parameter that in the dead time model is characteristic of the detector system, but rather, varies systematically with gate width.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

DN/DG Screening of Environmental Swipe Samples: FY2016 Report

The Delayed Neutron Delayed Gamma (DNDG) technique provides a new analytical capability to the International Atomic Energy Agency (IAEA) for detecting undeclared nuclear activities. IAEA’s Long Term R&D (LTRD) plan has a stated high urgency need to develop elemental and isotopic signatures of nuclear fuel cycle activities and processes (LTRD 2.2). The new DNDG capability is used to co-detect both uranium and plutonium as an extension of a DN only method that is already being utilized by the IAEA for the analysis of swipes to inform on undeclared nuclear activities. Analytical method involving irradiation of swipe samples potentially containing trace quantities of fissile material in a thermal neutron field, followed by the counting of delayed neutrons, is a well-known technique in the field of safeguards and nonproliferation. It is used for detecting the presence of microscopic amounts of fissile material, (typically a linear combination of 233 U, 235 U, 239 Pu, and 241 Pu)and quantifying it in terms of the equivalent mass of 235U. The delayed neutron (DN) technique is very sensitive and is been routinely employed at the High Flux Isotope Reactor (HFIR) facility at Oak Ridge National Laboratory (ORNL). Both uranium and plutonium are of high safeguards value. However, the DN technique is not well suited for distinguishing between U and Pu isotopes since the decay curves overlap closely. The delayed gamma (DG) technique will help detect the presence of 239Pu in a mixture of U and Pu. Thus the DNDG approach combines the best of both worlds; the sensitivity of DN counting and the isotopic specificity of DG counting. The present work seeks to build on the delayed neutron and delayed gamma methods that have been developed at ORNL. It is recognized that the distribution profile of heavy fission products remains fairly invariant for the fissile nuclides whereas the distribution of light fission products varies from one isotope to another. That is, the ratio of the yield of a light fission fragment to a heavy fission fragments is isotope specific. Measurement of the ratio of the net full energy peak (FEP) from low/high mass fission products is an elegant way to characterize the fraction of fissile materials present in a mixture. By empirically calibrating the ratio of the net FEP as a function of known concentration of the binary mixture, one can determine the fraction of fissile isotopes in an unknown sample. In the work done in fiscal year (FY) 2016, samples of single fissile material isotopes as well as binary mixtures were irradiated in a well thermalized irradiation field in the HFIR. Delayed neutron counting was performed using the neutron counter at the HFIR Neutron Activation Analysis (NAA) laboratory. Delayed gamma counting was performed using a shielded high purity germanium (HPGe) detector. Delayed neutron decay curve results highlighted the difficulty of distinguishing between U and Pu isotopes, and the need for including the delayed gamma component. Based on delayed gamma spectrometry, twelve ratios of low mass/high fission product gamma ray FEP have been identified as valid candidates. Linearity of the ratios, as a function of 239 Pu fraction in 235 U+ 239 Pu mixtures, was confirmed for the low mass/high mass candidates that were selected. The DNDG method we are spearheading allows not only the presence of total fissile content to be detected, but whether the material is predominantly U or predominantly Pu, or a mixture. This provides additional SG relevant information.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Boron-Coated Straw Collar for Uranium Neutron Coincidence Collar Replacement

The objective of this project was to design and optimize, in simulation space, an active neutron coincidence counter (or collar) using boron-coated straws (BCSs) as a non- 3 He replacement to the Uranium Neutron Coincidence Collar (UNCL). UNCL has been used by the International Atomic Energy Agency (IAEA) and European Atomic Energy Community (Euratom) since the 1980s to verify the 235 U content in fresh light water reactor fuel assemblies for safeguards purposes. This report documents the design and optimization of the BCS collar.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗