Sci—Fri AM: Mountain — 01: Validation of a new formulism and the related correction factors on output factor determination for small photon fields

Small field dosimetry measurements including output factors are difficult due to lack of charged-particle equilibrium, occlusion of the radiation source, the finite size of detectors, and non-water equivalence of detector components. With available detectors significant variations could be measured that will lead to incorrect delivered dose to patients. IAEA/AAPM have provided a framework and formulation to correct the detector response in small photon fields. Monte Carlo derived correction factors for some commonly used small field detectors are now available, however validation has not been performed prior to this study. An Exradin A16 chamber, EDGE detector and SFD detector were used to perform the output factor measurement for a series of conical fields (5–30mm) on a Varian iX linear accelerator. Discrepancies up to 20%, 10% and 6% were observed for 5, 7.5 and 10 mm cones between the initial output factors measured by the EDGE detector and the A16 ion chamber, while the discrepancies for the conical fields larger than 10 mm were less than 4%. After the application of the correction, the output factors agree well with each other to within 1%. Caution is needed when determining the output factors for small photon fields, especially for fields 10 mm in diameter or smaller. More than one type of detector should be used, each with proper corrections applied to the measurement results. It is concluded that with the application of correction factors to appropriately chosen detectors, output can be measured accurately for small fields.

60 APPLIED LIFE SCIENCES↗

Poster — Thur Eve — 13: Inter-Fraction Target Movement in Image-Guided Radiation Therapy of Prostate Cancer

We investigated the setup variations over the treatment courses of 113 patients with intact prostate treated with 78Gy/39fx. Institutional standard bladder and bowel preparation and image guidance protocols were used in CT simulation and treatment. The RapidArc treatment plans were optimized in Varian Eclipse treatment planning system and delivered on Varian 2100X Clinacs equipped with On-Board Imager to localize the target before beam-on. The setup variations were calculated in terms of mean and standard deviation of couch shifts. No correlation was observed between the mean shift and standard deviation over the treatment course and patient age, initial prostate volume and rectum size. The mean shifts in the first and last 5 fractions are highly correlated (P < 10{sup −10}) while the correlation of the standard deviations cannot be determined. The Mann-Kendall tests indicate trends of the mean daily Ant-Post and Sup-Inf shifts of the group. The target is inferior by ∼1mm to the planned position when the treatment starts and moves superiorly, approaching the planned position at 10th fraction, and then gradually moves back inferiorly by ∼1mm in the remain fractions. In the Ant-Post direction, the prostate gradually moves posteriorly during the treatment course from a mean shift of ∼2.5mm in the first fraction to ∼1mm in the last fraction. It may be related to a systematic rectum size change in the progress of treatment. The biased mean shifts in Ant-Post and Sup-Inf direction of most patients suggest systematically larger rectum and smaller bladder during the treatment than at CT simulation.

60 APPLIED LIFE SCIENCES↗

Massively parallel X-ray holography

Advances in the development of free-electron lasers offer the realistic prospect of nanoscale imaging on the timescale of atomic motions. We identify X-ray Fourier-transform holography1,2,3 as a promising but, so far, inefficient scheme to do this. We show that a uniformly redundant array4 placed next to the sample, multiplies the efficiency of X-ray Fourier transform holography by more than three orders of magnitude, approaching that of a perfect lens, and provides holographic images with both amplitude- and phase-contrast information. The experiments reported here demonstrate this concept by imaging a nano-fabricated object at a synchrotron source, and a bacterial cell with a soft-X-ray free-electron laser, where illumination by a single 15-fs pulse was successfully used in producing the holographic image. As X-ray lasers move to shorter wavelengths we expect to obtain higher spatial resolution ultrafast movies of transient states of matter