Search NASA⌕ Search

Engineering topics

Cui, Y.

Publications and source records attributed to Cui, Y..

At least 55 records · Page 3

Point defects: Their influence on electron trapping, resistivity, and electron mobility-lifetime product in CdTe{sub x}Se{sub 1−x} detectors

In this research, we assessed the abundance of point defects and their influence on the resistivity, the electron mobility-lifetime (μτ{sub e}) product, and the electron trapping time in CdTeSe crystals grown under different conditions using the traveling heater method. We used current-deep level transient spectroscopy to determine the traps' energy, their capture cross-section, and their concentration. Further, we used these data to determine the trapping and de-trapping times for the charge carriers. The data show that detectors with a lower concentration of In-dopant have a higher density of A-centers and Cd double vacancies (V{sub Cd}{sup - -}). The high concentrations of V{sub Cd}{sup - -} and A-centers, along with the deep trap at 0.86 eV and low density of 1.1 eV energy traps, are the major cause of the detectors' low resistivity, and most probably, a major contributor to the low μτ{sub e} product. Our results indicate that the energy levels of point defects in the bandgap, their concentrations, capture cross-sections, and their trapping and de-trapping times play an important role in the detector's performance, especially for devices that rely solely on electron transport.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Effects of magnetic field treatment on dielectric properties of CCTO@Ni/PVDF composite with low concentration of ceramic fillers

Using melt mixing, we produced a ceramic/polymer composite with a matrix of polyvinylidene fluoride (PVDF) and a filler of 5 vol.% Ni-deposited CaCu{sub 3}Ti{sub 4}O{sub 12} core-shell ceramic particles (CCTO@Ni), and studied its prominent dielectric characteristics for the first. Its phase composition and morphology were analyzed by X-ray diffraction and scanning electron microscopy, respectively. After treating the composite films with various durations of a magnetic field treatment, we compared their dielectric properties. We found that the CCTO@Ni ceramic had a typical urchin-like core-shell structure, and that different durations of the magnetic field treatment produced different distributions of ceramic particles in the PVDF matrix. The dielectric permittivity of the untreated CCTO@Ni/PVDF composite was 20% higher than that of neat PVDF, and it had a low loss tangent. However, only the composite treated for 30 min in the magnetic field had an ultra-high dielectric permittivity of 1.41 × 10{sup 4} at 10 Hz, three orders of magnitude higher than the untreated composite, which declined dramatically with increasing frequency, accompanied by an insulating-conducting phase transition and an increase in loss tangent. Our results demonstrate that changes in the dielectric properties of PVDF composites with magnetic field treatment are closely related to the percolation effect and interfacial polarization.

36 MATERIALS SCIENCE↗

High-Efficiency CdZnTe Position-Sensitive VFG Gamma-Ray Detectors for Safeguards Applications

The goal of this project is to incorporate a Cadmium-Zinc-Telluride (CdZnTe or CZT) detector (with 1% or better resolution) into a bench-top prototype for isotope identification and related safeguards applications. The bench-top system is based on a 2x2 array of 6x6x20 mm 3 position-sensitive virtual Frisch-grid (VFG) CZT detectors. The key features of the array are that it allows for the use of average-grade CZT material with a moderate content of defects, and yet it provides high energy resolution, 1% FWHM at 662 keV, large effective area, and low-power consumption. The development of this type of 3D detector and new instruments incorporating them is motivated by the high cost and low availability of large, > 1 cm 3 , CZT crystals suitable for making multi-pixel detectors with acceptable energy resolution and efficiency.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Use of high-granularity CdZnTe pixelated detectors to correct response non-uniformities caused by defects in crystals

Following our successful demonstration of the position-sensitive virtual Frisch-grid detectors, we investigated the feasibility of using high-granularity position sensing to correct response non-uniformities caused by the crystal defects in CdZnTe (CZT) pixelated detectors. The development of high-granularity detectors able to correct response non-uniformities on a scale comparable to the size of electron clouds opens the opportunity of using unselected off-the-shelf CZT material, whilst still assuring high spectral resolution for the majority of the detectors fabricated from an ingot. Here, we present the results from testing 3D position-sensitive 15×15×10 mm 3 pixelated detectors, fabricated with conventional pixel patterns with progressively smaller pixel sizes: 1.4, 0.8, and 0.5 mm. We employed the readout system based on the H3D front-end multi-channel ASIC developed by BNL's Instrumentation Division in collaboration with the University of Michigan. We use the sharing of electron clouds among several adjacent pixels to measure locations of interaction points with sub-pixel resolution. By using the detectors with small-pixel sizes and a high probability of the charge-sharing events, we were able to improve their spectral resolutions in comparison to the baseline levels, measured for the 1.4-mm pixel size detectors with small fractions of charge-sharing events. These results demonstrate that further enhancement of the performance of CZT pixelated detectors and reduction of costs are possible by using high spatial-resolution position information of interaction points to correct the small-scale response non-uniformities caused by crystal defects present in most devices.

36 MATERIALS SCIENCE↗

An array of virtual Frisch-grid CdZnTe detectors and a front-end application-specific integrated circuit for large-area position-sensitive gamma-ray cameras

We developed a robust and low-cost array of virtual Frisch-grid CdZnTe (CZT) detectors coupled to a front-end readout ASIC for spectroscopy and imaging of gamma rays. The array operates as a self-reliant detector module. It is comprised of 36 close-packed 6x6x15 mm 3 detectors grouped into 3x3 sub-arrays of 2x2 detectors with the common cathodes. The front-end analog ASIC accommodates up to 36 anode and 9 cathode inputs. Several detector modules can be integrated into a single- or multi-layer unit operating as a Compton or a coded-aperture camera. We present the results from testing two fully assembled modules and readout electronics. The further enhancement of the arrays’ performance and reduction of their cost are made possible by using position-sensitive virtual Frisch-grid detectors, which allow for accurate corrections of the response of material non-uniformities caused by crystal defects.

36 MATERIALS SCIENCE↗

Magneto-transport anisotropy in epitaxially grown hybrid MnAs/GaAs multilayer

Using molecular-beam epitaxy, we grew a MnAs/GaAs multilayer on a GaAs(100) substrate and compared its magneto-transport characteristics to those of a single-layer MnAs thin film. The crystal orientation of the MnAs layers in both samples was type-B. M–H measurements revealed two-fold symmetric magnetic anisotropy on the surface with the easy and hard direction of magnetization. When the current flowed along the hard direction, the MnAs/GaAs multilayer exhibited negative magnetoresistance below Curie temperature; when the current flowed along the easy direction, it turned positive. We suggest that this peculiar anisotropic magneto-transport behavior in the multilayer originated from two-dimensional carrier confinement and spin-orbit coupling.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Voltammetric and impedance behaviours of surface-treated nano-crystalline diamond film electrodes

The electrochemical performances of hydrogen- and oxygen-terminated nano-crystalline diamond film electrodes were investigated by cyclic voltammetry and AC impedance spectroscopy. In addition, the surface morphologies, phase structures, and chemical states of the two diamond films were analysed by scanning probe microscopy, Raman spectroscopy, and X-ray photoelectron spectroscopy, respectively. The results indicated that the potential window is narrower for the hydrogen-terminated nano-crystalline diamond film than for the oxygen-terminated one. The diamond film resistance and capacitance of oxygen-terminated diamond film are much larger than those of the hydrogen-terminated diamond film, and the polarization resistances and double-layer capacitance corresponding to oxygen-terminated diamond film are both one order of magnitude larger than those corresponding to the hydrogen-terminated diamond film. The electrochemical behaviours of the two diamond film electrodes are discussed.

36 MATERIALS SCIENCE↗

Point defects in CdTe x Se 1-x crystals grown from a Te-rich solution for applications in detecting radiation

We investigated cadmium telluride selenide (CdTeSe) crystals, newly grown by the Traveling Heater Method (THM), for the presence and abundance of point defects. Deep Level Transient spectroscopy (I-DLTS) was used to determine the energies of the traps, their capture cross sections, and densities. The bias across the detectors was varied from (1–30) V. Four types of point defects were identified, ranging from 10 meV to 0.35 eV. Two dominant traps at energies of 0.18 eV and 0.14 eV were studied in depth. Cd vacancies are found at lower concentrations than other point defects present in the material.

36 MATERIALS SCIENCE↗

The 2012 flare of PG 1553+113 seen with H.E.S.S. and Fermi-LAT

Very high energy (VHE, E > 100 GeV) γ-ray flaring activity of the high-frequency peaked BL Lac object PG 1553+113 has been detected by the H.E.S.S. telescopes. Also, the flux of the source increased by a factor of 3 during the nights of 2012 April 26 and 27 with respect to the archival measurements with a hint of intra-night variability. No counterpart of this event has been detected in the Fermi-Large Area Telescope data. This pattern is consistent with VHE γ-ray flaring being caused by the injection of ultrarelativistic particles, emitting γ-rays at the highest energies. The dataset offers a unique opportunity to constrain the redshift of this source at z = 0.49 ± 0.04 using a novel method based on Bayesian statistics. In addition, the indication of intra-night variability is used to introduce a novel method to probe for a possible Lorentz invariance violation (LIV), and to set limits on the energy scale at which Quantum Gravity (QG) effects causing LIV may arise. For the subluminal case, the derived limits are E QG,1 > 4.10 × 10 17 GeV and E QG,2 > 2.10 × 10 10 GeV for linear and quadratic LIV effects, respectively.

79 ASTRONOMY AND ASTROPHYSICS↗

Probing the gamma-ray emission from HESS J1834–087 using H.E.S.S. and Fermi LAT observations

Aims. Previous observations with the High Energy Stereoscopic System (H.E.S.S.) have revealed an extended very-high-energy (VHE; E> 100 GeV) γ-ray source, HESS J1834-087, coincident with the supernova remnant (SNR) W41. The origin of the γ-ray emission was investigated in more detail with the H.E.S.S. array and the Large Area Telescope (LAT) onboard the Fermi Gamma-ray Space Telescope. Methods. For this research, the γ-ray data provided by 61 h of observations with H.E.S.S., and four years with the Fermi LAT were analyzed, covering over five decades in energy from 1.8 GeV up to 30 TeV. The morphology and spectrum of the TeV and GeV sources were studied and multiwavelength data were used to investigate the origin of the γ-ray emission toward W41. Results. The TeV source can be modeled with a sum of two components: one point-like and one significantly extended (σ TeV = 0.17° ± 0.01°), both centered on SNR W41 and exhibiting spectra described by a power law with index Γ TeV ≃ 2.6. The GeV source detected with Fermi LAT is extended (σ GeV = 0.15° ± 0.03°) and morphologically matches the VHE emission. Its spectrum can be described by a power-law model with an index Γ GeV = 2.15 ± 0.12 and smoothly joins the spectrum of the whole TeV source. A break appears in the γ-ray spectra around 100 GeV. No pulsations were found in the GeV range. Conclusions. Two main scenarios are proposed to explain the observed emission: a pulsar wind nebula (PWN) or the interaction of SNR W41 with an associated molecular cloud. X-ray observations suggest the presence of a point-like source (a pulsar candidate) near the center of the remnant and nonthermal X-ray diffuse emission that could arise from the possibly associated PWN. The PWN scenario is supported by the compatible positions of the TeV and GeV sources with the putative pulsar. However, the spectral energy distribution from radio to γ-rays is reproduced by a one-zone leptonic model only if an excess of low-energy electrons is injected following a Maxwellian distribution by a pulsar with a high spin-down power (>1037 erg s-1). This additional low-energy component is not needed if we consider that the point-like TeV source is unrelated to the extended GeV and TeV sources. Finally, the interacting SNR scenario is supported by the spatial coincidence between the γ-ray sources, the detection of OH (1720 MHz) maser lines, and the hadronic modeling.

79 ASTRONOMY AND ASTROPHYSICS↗

Material and detector properties of cadmium manganese telluride (Cd 1-x Mn x Te) crystals grown by the modified floating-zone method

We demonstrated the material- and radiation-detection properties of cadmium manganese telluride (Cd 1-x Mn x Te; x=0.06), a wide-band-gap semiconductor crystal grown by the modified floating-zone method. We investigated the presence of various bulk defects, such as Te inclusions, twins, and dislocations of several as-grown indium-doped Cd 1-x Mn x Te crystals using different techniques, viz., IR transmission microscopy, and chemical etching. We then fabricated four planar detectors from selected CdMnTe crystals, characterized their electrical properties, and tested their performance as room-temperature X- and gamma-ray detectors. Thus, our experimental results show that CMT crystals grown by the modified floating zone method apparently are free from Te inclusions. However, we still need to optimize our growth parameters to attain high-resistivity, large-volume single-crystal CdMnTe.

36 MATERIALS SCIENCE↗

The high-energy γ -ray emission of AP Librae

In this paper, the γ-ray spectrum of the low-frequency-peaked BL Lac (LBL) object AP Librae is studied, following the discovery of very-high-energy (VHE; E> 100 GeV) γ-ray emission up to the TeV range by the H.E.S.S. experiment. This makes AP Librae one of the few VHE emitters of the LBL type. The measured spectrum yields a flux of (8.8 ± 1.5 stat ± 1.8 sys ) × 10 -12 cm -2 s -1 above 130 GeV and a spectral index of Γ = 2.65 ± 0.19 stat ± 0.20 sys . This study also makes use of Fermi-LAT observations in the high energy (HE, E> 100 MeV) range, providing the longest continuous light curve (5 years) ever published on this source. The source underwent a flaring event between MJD 56 306–56 376 in the HE range, with a flux increase of a factor of 3.5 in the 14 day bin light curve and no significant variation in spectral shape with respect to the low-flux state. While the H.E.S.S. and (low state) Fermi-LAT fluxes are in good agreement where they overlap, a spectral curvature between the steep VHE spectrum and the Fermi-LAT spectrum is observed. Finally, the maximum of the γ-ray emission in the spectral energy distribution is located below the GeV energy range.

79 ASTRONOMY AND ASTROPHYSICS↗