Internal electric-field-lines distribution in CdZnTe detectors measured using X-ray mapping

The ideal operation of CdZnTe devices entails having a uniformly distributed internal electric field. Such uniformity especially is critical for thick long-drift-length detectors, such as large-volume CPG and 3-D multi-pixel devices. Using a high-spatial resolution X-ray mapping technique, we investigated the distribution of the electric field in real devices. Our measurements demonstrate that in thin detectors, <5 mm, the electric field-lines tend to bend away from the side surfaces (i.e., a focusing effect). In thick detectors, >1 cm, with a large aspect ratio (thickness-to-width ratio), we observed two effects: the electric field lines bending away from or towards the side surfaces, which we called, respectively, the focusing field-line distribution and the defocusing field-line distribution. In addition to these large-scale variations, the field-line distributions were locally perturbed by the presence of extended defects and residual strains existing inside the crystals. We present our data clearly demonstrating the non-uniformity of the internal electric field.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigations of Cadmium Manganese Telluride Crystals for Room-Temperature Radiation Detection

Cadmium manganese telluride (CMT) has high potential as a material for room-temperature nuclear-radiation detectors. We investigated indium-doped CMT crystals taken from the stable growth region of the ingot, and compared its characteristics with that from the last-to-freeze region. We employed different techniques, including synchrotron white-beam X-ray topography (SWBXT), current-voltage (I-V) measurements, and low-temperature photoluminescence spectra, and we also assessed their responses as detectors to irradiation exposure. The crystal from the stable growth region proved superior to that from the last-to-freeze region; it is a single-grain crystal, free of twins, and displayed a resistivity higher by two orders-of-magnitude. The segregation of indium dopant in the ingot might be responsible for its better resistivity. Furthermore, we recorded a good response in the detector fabricated from the crystal taken from the stable growth region; its ({mu}{tau}){sub e} value was 2.6 x 10{sup -3} cm{sup 2}/V, which is acceptable for thin detectors, including for applications in medicine.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Electric Field Distribution of Cadmium Zinc Telluride (CZT)

Cadmium Zinc Telluride (CZT) is attracting increasing interest with its promise as a room-temperature nuclear-radiation-detector material. The distribution of the electric field in CZT detectors substantially affects their detection performance. At Brookhaven National Laboratory (BNL), we employed a synchrotron X-Ray mapping technique and a Pockels-effect measurement system to investigate this distribution in different detectors. Here, we report our latest experimental results with three detectors of different width/height ratios. A decrease in this ratio aggravates the non-uniform distribution of electric field, and focuses it on the central volume. Raising the bias voltage effectively can minimize such non-uniformity of the electric field distribution. The position of the maximum electric field is independent of the bias voltage; the difference between its maximum- and minimum-intensity of electric field increases with the applied bias voltage.

43 PARTICLE ACCELERATORS↗

Tapping mode microwave impedance microscopy

We report tapping mode microwave impedance imaging based on atomic force microscope platforms. The shielded cantilever probe is critical to localize the tip-sample interaction near the tip apex. The modulated tip-sample impedance can be accurately simulated by the finite-element analysis and the result agrees quantitatively to the experimental data on a series of thin-film dielectric samples. The tapping mode microwave imaging is also superior to the contact mode in that the thermal drift in a long time scale is totally eliminated and an absolute measurement on the dielectric properties is possible. We demonstrated tapping images on working nanodevices, and the data are consistent with the transport results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Opto-electrical characterization and X-ray mapping of large-volume cadmium zinc telluride radiation detectors

Large-volume cadmium zinc telluride (CZT) radiation detectors would greatly improve radiation detection capabilities and, therefore, attract extensive scientific and commercial interests. CZT crystals with volumes as large as hundreds of centimeters can be achieved today due to improvements in the crystal growth technology. However, the poor performance of large-volume CZT detectors is still a challenging problem affecting the commercialization of CZT detectors and imaging arrays. We have employed Pockels effect measurements and synchrotron X-ray mapping techniques to investigate the performance-limiting factors for large-volume CZT detectors. Experimental results with the above characterization methods reveal the non-uniform distribution of internal electric field of large-volume CZT detectors, which help us to better understand the responsible mechanism for the insufficient carrier collection in large-volume CZT detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

CZT Virtual Frisch-grid Detector: Principles and Applications

Cadmium Zinc Telluride (CdZnTe or CZT) is a very attractive material for using as room-temperature semiconductor detectors, because it has a wide bandgap and a high atomic number. However, due to the material's poor hole mobility, several special techniques were developed to ensure its suitability for radiation detection. Among them, the virtual Frisch-grid CZT detector is an attractive option, having a simple configuration, yet delivering an outstanding spectral performance. The goal of our group in Brookhaven National Laboratory (BNL) is to improve the performance of Frisch-ring CZT detectors; most recently, that effort focused on the non-contacting Frisch-ring detector, allowing us to build an inexpensive, large-volume detector array with high energy-resolution and a large effective area. In this paper, the principles of virtual Frisch-grid detectors are described, especially BNL's innovative improvements. The potential applications of virtual Frisch-grid detectors are discussed, and as an example, a hand-held gamma-ray spectrometer using a CZT virtual Frischgrid detector array is introduced, which is a self-contained device with a radiation detector, readout circuit, communication circuit, and high-voltage supply. It has good energy resolution of 1.4% (FWHM of 662-keV peak) with a total detection volume of {approx}20 cm{sup 3}. Such a portable inexpensive device can be used widely in nonproliferation applications, non-destructive detection, radiation imaging, and for homeland security. Extended systems based on the same technology have potential applications in industrial- and nuclear-medical-imaging.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Material properties limiting the performance of CZT gamma-ray detectors

CdZnTe (CZT) nuclear radiation detectors are advanced sensors that utilize innovative technologies developed for wide band-gap semiconductor industry and microelectronics. They open opportunities for new types of room-temperature operating, field deployable instruments that provide accurate identification of potential radiological threats and timely awareness for both the civilian and military communities. Room-temperature radiation detectors are an emerging technology that relies on the use of high-quality CZT crystals whose availability is currently limited by material non-uniformities and the presence of extended defects. To address these issues, which are most critical to CZT sensor developments, we developed X-ray mapping and IR transmission microscopy systems to characterize both CZT crystals and devices. Since a customized system is required for such X-ray measurements, we use synchrotron radiation beams available at BNL's National Synchrotron Light Source. A highly-collimated and high-intensity X-ray beam supports measurements of areas as small as 10 x 10 {micro}m{sup 2}, and allowed us to see fluctuations in collected charge over the entire area of the detector in a reasonable time. The IR microscopy system allows for 3D visualization of Te inclusions and other extended defects. In this paper, we describe the experimental techniques used in our measurements and typical results obtained from CZT samples produced by different suppliers.

43 PARTICLE ACCELERATORS↗

Internal Electric Field Investigations of a Cadmium Zinc Telluride Detector Using Synchrotron X-ray Mapping and Pockels Effect Measurements

Cadmium zinc telluride (CZT) has remained a major focus of research due to its promising application as a room-temperature nuclear radiation detector material. Among the several parameters that substantially affect the detectors' performance, an important one is the distribution of the internal electric field. Brookhaven National Laboratory (BNL) employed synchrotron x-ray microscale mapping and measurements of the Pockels effect to investigate the distribution of the internal electric field in a CZT strip detector. Direct evidence that dislocations can distort the internal electric field of the detector was obtained. Furthermore, it was found that 'star' defects in the CZT crystal, possibly ascribed to dislocation loop punching, cause charge trapping.

43 PARTICLE ACCELERATORS↗

Internal Electric-Field-Lines Distribution in Cdznte Detectors Measured Using X-ray Mapping

The ideal operation of CdZnTe devices entails having a uniformly distributed internal electric field. Such uniformity especially is critical for thick long-drift-length detectors, such as large-volume CPG and 3-D multi-pixel devices. Using a high-spatial resolution X-ray mapping technique, we investigated the distribution of the electric field in real devices. Our measurements demonstrate that in thin detectors, < 5 mm, the electric field-lines tend to bend away from the side surfaces (i.e., a focusing effect). In thick detectors, > 1 cm, with a large aspect ratio (thickness-to-width ratio), we observed two effects: the electric field lines bending away from or towards the side surfaces, which we called, respectively, the focusing field-line distribution and the defocusing field-line distribution. In addition to these large-scale variations, the field-line distributions were locally perturbed by the presence of extended defects and residual strains existing inside the crystals. We present our data clearly demonstrating the non-uniformity of the internal electric field.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Extended Defects in Cdznte Radiation Detectors

Large-volume CdZnTe (CZT) single crystals with electron lifetime exceeding 10 mus have recently become commercially available. This opened the opportunity for making room temperature CZT gamma-ray detectors with extended thicknesses and larger effective areas. However, the extended defects that are present even in the highest-quality material remain a major drawback which affects the availability and cost of large CZT detectors. In contrast to the point defects that control electron lifetime and whose effects on the charge collection can be electronically corrected, the extended defects introduce significant fluctuations in the collected charge, which increase with a crystal's thickness. The extended defects limit the uniformity in the electrons' drift distance in CZT crystals, above which electron trapping cannot effectively be corrected. In this paper, we illustrate the roles of the extended defects in CZT detectors with different geometries. We emphasize that the crystallinity of commercial CZT materials remains a major obstacle on the path to developing thick, large-volume CZT detectors for gamma-ray imaging and spectroscopy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of Te Inclusions on the Performance of Cdznte Radiation Detectors

Te inclusions existing at high concentrations in CdZnTe (CZT) material can degrade the performance of CZT detectors. These microscopic defects trap the free electrons generated by incident radiation, so entailing significant fluctuations in the total collected charge and thereby strongly affecting the energy resolution of thick (long-drift) detectors. Such effects were demonstrated in thin planar detectors, and, in many cases, they proved to be the dominant cause of the low performance of thick detectors, wherein the fluctuations in the charge losses accumulate along the charge's drift path. We continued studying this effect using different tools and techniques. We employed a dedicated beamline recently established at BNL's National Synchrotron Light Source for characterizing semiconductor radiation detectors, along with an IR transmission microscope system, the combination of which allowed us to correlate the concentration of defects with the devices' performances. We present here our new results from testing over 50 CZT samples grown by different techniques. Our goals are to establish tolerable limits on the size and concentrations of these detrimental Te inclusions in CZT material, and to provide feedback to crystal growers to reduce their numbers in the material.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Impurity Gettering Effect of Te Inclusions in Cdznte Single Crystals

The local impurity distribution in Te inclusions of CdZnTe (CZT) crystal was investigated by the time-of-flight secondary ion mass spectrometry (Tof-SIMS) technique. Direct evidence of impurity gettering in Te inclusions has been observed for the first time. The impurity gettering in Te inclusions originated from the diffusion mechanism during crystal growth and segregation mechanism during crystal cooling. This phenomenon is meaningful, because it reveals how Te inclusions affect CZT properties and provides a possible approach to reduce the impurities in CZT by the way of removing Te inclusions.

36 MATERIALS SCIENCE↗