Development of Photocathodes for high spin polarized electron sources at Brookhaven National Laboratory
Explore the source record for details and available documents.
Engineering topics
Publications and source records attributed to Cultrera, Luca.
Explore the source record for details and available documents.
Photon detectors featuring single-photon sensitivity play a crucial role in various scientific domains, including high-energy physics, astronomy, and quantum optics. Fast response time, high quantum efficiency, and minimal dark counts are the characteristics that render them ideal candidates for detecting individual photons with exceptional signal-to-noise ratios, at frequencies in the range of hundreds of MHz. Here, in this study, we report on our first design and operational results on a Hybrid Photon Detector (HPD) that combines the high quantum efficiency of a Gallium Nitride (GaN) photocathode and the low noise characteristics of a Si-based Low-Gain Avalanche Diode (LGAD). This hybrid detection scheme has the potential to reach single-photon detection sensitivity with high quantum efficiency, low noise levels and capable of operating at hundreds of MHz repetition rates.
Explore the source record for details and available documents.
Driven by life-science applications, a mega-electron-volt Scanning Transmission Electron Microscope (MeV-STEM) has been proposed here to image thick frozen biological samples as a conventional Transmission Electron Microscope (TEM) may not be suitable to image samples thicker than 300–500 nm and various volume electron microscopy (EM) techniques either suffering from low resolution, or low speed. The high penetration of inelastic scattering signals of MeV electrons could make the MeV-STEM an appropriate microscope for biological samples as thick as 10 μm or more with a nanoscale resolution, considering the effect of electron energy, beam broadening, and low-dose limit on resolution. The best resolution is inversely related to the sample thickness and changes from 6 nm to 24 nm when the sample thickness increases from 1 μm to 10 μm. To achieve such a resolution in STEM, the imaging electrons must be focused on the specimen with a nm size and an mrad semi-convergence angle. This requires an electron beam emittance of a few picometers, which is ~1000 times smaller than the presently achieved nm emittance, in conjunction with less than 10 -4 energy spread and 1 nA current. We numerically simulated two different approaches that are potentially applicable to build a compact MeV-STEM instrument: (1) DC (Direct Current) gun, aperture, superconducting radio-frequency (SRF) cavities, and STEM column; (2) SRF gun, aperture, SRF cavities, and STEM column. Beam dynamic simulations show promising results, which meet the needs of an MeV-STEM, a few-picometer emittance, less than 10 -4 energy spread, and 0.1–1 nA current from both options. Also, we designed a compact STEM column based on permanent quadrupole quintuplet, not only to demagnify the beam size from 1 μm at the source point to 2 nm at the specimen but also to provide the freedom of changing the magnifications at the specimen and a scanning system to raster the electron beam across the sample with a step size of 2 nm and the repetition rate of 1 MHz. This makes it possible to build a compact MeV-STEM and use it to study thick, large-volume samples in cell biology.
Photocathodes based on GaAs and other III–V semiconductors are capable of producing highly spin-polarized electron beams. GaAs/GaAsP superlattice photocathodes exhibit high spin polarization; however, the quantum efficiency (QE) is limited to 1% or less. To increase the QE, we fabricated a GaAs/GaAsP superlattice photocathode with a Distributed Bragg Reflector (DBR) underneath. This configuration creates a Fabry–Pérot cavity between the DBR and GaAs surface, which enhances the absorption of incident light and, consequently, the QE. These photocathode structures were grown using molecular beam epitaxy and achieved record quantum efficiencies exceeding 15% and electron spin polarization of about 75% when illuminated with near-bandgap photon energies.
Here, we present commissioning results of the High ElectRon Average Current for Lifetime ExperimentS (HERACLES) beamline at Cornell University. 10 mA average beam current at 200 keV was achieved with a Cs3Sb photocathode operated with an Argon laser at 488 nm. HERACLES is intended to be a test facility to improve the robustness of photocathodes developed for high average current beam operation in conjunction with the Cornell photocathode laboratory.
Here, we explore the use of room-temperature ionic liquids (ILs) as Raman wavelength converters. ILs provide an engineerable framework to design suitable liquids for wavelength conversion over a broad spectral range, through careful selection of the molecular structures of the IL anions and cations so that specific characteristics can be obtained, such as a desirable Raman shift, low Brillouin scattering, and good optical transmission in the pump and Stokes wavelengths. Applying such criteria, we demonstrate that 1-ethyl-3-methylimidazolium dicyanamide (EMIM DCA) is an effective medium for conversion of 532-nm pulses from a Q-switched Nd :YAG laser to 603 nm. This corresponds to an approximate 2200 cm –1 shift, which can be used to generate mid-infrared radiation through subsequent difference frequency generation for optical pumping of CO 2 lasers. Threefold-higher Raman conversion efficiency is obtained in EMIM DCA compared with water under identical conditions in a proof-of-principle single-pass conversion setup, resulting in an efficient generation of multimillijoule, <6 ns duration, high-quality orange laser pulses in a wavelength region that is difficult to access at high energies. Consequently, we examine ILs representing two other classes of Raman-active functional groups and obtain conversion up to the fifth-order Stokes shift and first anti-Stokes shift. Through the tunable selection of their components and their useful dynamical properties, ILs provide a platform for efficient, simple, and alignment-tolerant high-energy Raman shifting with numerous industrial and technological applications.