Search NASA⌕ Search

Engineering topics

Cureton, Will [ORNL] (ORCID:0000000319764150)

Publications and source records attributed to Cureton, Will [ORNL] (ORCID:0000000319764150).

Irradiation of UC1+x kernels using the MiniFuel vehicle: Microstructure, phase analysis, and initial post-irradiation examination

Uranium carbide is a candidate fuel form for a wide range of advanced reactors, including larger Generation IV reactors as well as small modular reactors and microreactors. However, its commercial deployment timeline faces challenges via traditional qualification approaches. To address this issue, an accelerated fission rate irradiation test was performed to collect basic fuel performance data to inform fuel performance models and potential future integral tests. Hyperstoichiometric UC (UC1+x) kernels were irradiated in the High Flux Isotope Reactor using the MiniFuel irradiation vehicle. The test matrix spanned two temperature regimes (700 °C and 800 °C) and burnup levels (1.8 % FIMA and 2.8 % FIMA). Between 21 and 63 kernels were tested at each unique temperature and burnup condition. As-fabricated microstructural analysis revealed a multiphase composition with UC, UC2, UC2−y, and U-C-O bearing phases for the irradiated kernels. Following irradiation, fission gas release, swelling, and microstructures were analyzed. Measured fission gas release was below 5 % for all irradiation conditions, reaching a maximum at the highest temperature and burnup condition. A binary swelling response was observed; the lower burnup and temperature conditions resulted in negligible swelling, but the higher burnup and temperature conditions produced significant anisotropic swelling and densification in a subset of kernels. The basic microstructural exams of kernels following irradiation were not capable of showing a correlation between kernels that exhibited excessive swelling and those that did not. Characterization of a subset of samples using the Advanced Photon Source and more detailed microstructural examination of unirradiated kernels revealed that a subset of kernels contained very high UC2 phase fractions. The anomalous swelling response is hypothesized to have been driven by this chemical variation. The results of this irradiation highlight the potential of accelerated fission rate irradiation testing to explore such behaviors and inform the development of fuel specifications.

Adorno Lopes, Denise [ORNL] (ORCID:000900023705987↗

Quantitative measurement of pebble fuel anisotropy using generalized ellipsometry

The renewed development of high-temperature gas-cooled reactors has created a need to modernize pebble fuel quality control methods. One important specification in these methods is the coefficient of thermal expansion (CTE) anisotropy, which reflects graphite grain alignment and affects fuel performance. This study investigates the feasibility of using two-modulator generalized ellipsometry microscopy (2-MGEM) as a potential surrogate metric for CTE anisotropy. Graphite matrix compacts with controlled levels of anisotropy were fabricated by varying pre-pressures during forming and were subsequently characterized using both optical dilatometry and 2-MGEM. Measured responses were compared to an isotropic reference pebble produced using an industrial manufacturing process to provide a practical baseline. The resulting measurements revealed a strong quantitative correlation between the CTE anisotropy ratio and the corresponding diattenuation ratio. However, propagated measurement uncertainties in the optical method were found to limit definitive pass/fail discrimination, highlighting the need for improved precision before qualification as a quality control tool. Still, the results establish a quantitative relationship between optical and CTE anisotropy and support further development of 2-MGEM as a potential surrogate method for evaluating graphite matrix anisotropy in pebble fuel manufacturing.

Raftery, Alicia [ORNL] (ORCID:0000000259076427)↗

SILICON CARBIDE THERMOMETRY USING RAMAN SPECTROSCOPY ON IRRADIATED TRISO PARTICLES

Silicon carbide (SiC) passive thermometry has emerged as a promising post-irradiation examination (PIE) technique for estimating irradiation temperature near the end of irradiation. While dilatometry techniques have been traditionally used to analyze prismatic samples after irradiation, Raman spectroscopy has recently been shown to provide comparable results by analyzing Raman-active phonon modes. In this work, Raman spectroscopy has been applied to the SiC layer of cross-sectioned irradiation tristructural isotropic (TRISO) particles from the AGR-5/6/7 experiment to evaluate the feasibility of particle-scale passive thermometry. Two-dimensional Raman mapping was used to measure the position of the SiC longitudinal optical (LO) phonon, which was then converted to an apparent irradiation temperature using a previously established empirical correlation. Particles from AGR-5/6/7 Compacts 2-2-1 and 5-1-3 were selected as their calculated time-averaged, volume-averaged (TAVA) temperatures (828°C and 706°C, respectively) fall within the range of the sensitivity of the experimental approach. The use of SiC thermometry was anticipated to confirm or highlight potential deviations from calculated end-of-life TAVA temperature across compacts. Four particles from Compact 2-2-1 and two particles from Compact 5-1-3 were selected based on 110mAg inventory (either some measurable activity or below the minimum detection limit) which is commonly used as an indicator of in-pile temperature variation of particles within the same compact. Across every particle selected it was determined that the average LO peak position was located around 968 cm-1 to 969 cm-1. Using the previously determined empirical correlation, this corresponds to an irradiation temperature around 950°C to 966°C, which does not align with the reported TAVA temperature values. This discrepancy in apparent irradiation temperatures likely reflects a combination of uncertainties in the calculated particle temperatures and differences in irradiation history between the present specimens and those used to establish the empirical Raman calibration such as neutron flux (damage rate) and SiC microstructure (as fabricated and irradiated).

Vawdrey, Josh [ORNL]↗

Optical functions of crystalline and amorphous TeO2

The optical functions of crystalline paratellurite (α-TeO2) and amorphous TeO2 were determined using several optical techniques: (1) standard spectroscopic two-modulator generalized ellipsometry (2-MGE) of paratellurite (200–850 nm, 6.2–1.46 eV), (2) near-normal-incidence two-modulator generalized ellipsometry microscopy (2-MGEM) of paratellurite (577 nm, 2.15 eV), (3) Mueller matrix transmission of paratellurite (320–798 nm, 3.87–1.55 eV), and (4) polarized transmission of paratellurite (323.6–334.3 nm, 3.83–3.71 eV). The 2-MGE measurements yielded highly accurate values of the dielectric functions and error estimates from 1.46 to 6.2 eV for both paratellurite and amorphous TeO2, whereas the polarization-dependent transmission yielded more accurate values of the absorption coefficient below the band edge of paratellurite. The 2-MGEM measured the diattenuation of paratellurite, which is related to the birefringence. Mueller matrix transmission measurements of paratellurite of a (001) cut crystal as a function of angle of incidence were used to determine both the birefringence and the rotary power as a function of photon energy.

Jellison Jr, Gerald [ORNL]↗