Search NASASearch

Engineering topics

Curtis, C. C.

Publications and source records attributed to Curtis, C. C..

Coded aperture devices for viewing extended objects from space

Coded aperture sensors for photons or energetic neutral atoms (ENAs), which incorporate FOV limiters and subdivide the object field into a number of elements which is smaller than the number of detector pixels, are described. A least squares fit to the data is made in reconstructing the object field. To evaluate the optics and reconstruction algorithms, two 'breadboard' sensors have been constructed, one based on a film camera and the other upon a UV-light sensitive microchannel plate detector system. Results obtained thus far show that the concept is viable, and no special difficulties should be encountered in adapting the detector geometries to neutral particle imaging systems. Charged particle deflection plates could be incorporated into the region between the FOV limiter and the aperture, or installed ahead of the limiter.

Curtis, C. C.

Aperture codes for sensors viewing extended objects from space

The paper describes aperture codes viewing extended objects form space which find application in imaging an extended object which may have relatively low contrast, and whose lateral limits extend beyond the FOV of the sensor. Those elements of an extended object lying near the FOV limits are only partially coded, i.e., flux from those elements cannot cast a shadow of the entire aperture code onto the detector, as can elements near the center of the FOV. This has consequences for the algorithms used to reconstruct the image. The object field is divided into a number of elements which is smaller than the number of detector pixels, and a least squares fit to the data is performed. The methods used for choosing the matrices representing the aperture codes are discussed, and computer simulations of the effects of noise are described.

Curtis, C. C.

Techniques for the remote sensing of space plasma in the heliosphere via energetic neutral atoms - A review

A survey is conducted for state-of-the-art techniques for detecting energetic neutral atoms (ENAs) in the 100-300 keV range, in regions from the heliospheric boundary to the auroral zones where the solar wind plays a crucial role. While ENA spectrometry allows sampling of the mass and energy distributions of a distant plasma, ENA imaging gives a global view of the structures and dynamics of an extended plasma. The ENA instrument designs discussed share many components which exhibit excellent flight performance as elements in charged-particle analyzers for space missions.

Hsieh, K. C.

Compact wide-aperture hyperbolic analyzers

Compact electrostatic analyzers that employ a new geometry are described. They accept collimated beams of ions through relatively wide (non-slit-like) inlet apertures and focus them at various locations, depending on the ion energy per charge, along rectangular position-sensing detectors. Each analyzer has a dynamic range of 10 or more for a fixed deflection voltage. The focal line width at a given energy is a small fraction of the inlet aperture width, and the focal lines are approximately coplanar.

Curtis, C. C.

A model for the spatial and energy distributions of energetic neutral atoms produced within the Saturn/Titan plasma system

A model for the production of energetic neutral atoms (ENAs) in the Saturn/Titan system, that takes into account existing data on the spatial distribution of the background neutral density, the energy and spatial distributions of the energetic ions, and the energy dependence of the charge-exchange cross sections, is presented. Hydrogen production via H(+), H is presented in detail. The extended Saturn/Titan system is 'imaged' in energetic neutral H at 66 R(s) and 25-deg latitude. From this vantage point, the energetic H flux is 6 + or - 1 H/sq cm per sec between 10 and 100 keV. Comparing the predicted H spectrum with that observed by Kirsch et al. (1981), the production of neutral O is estimated, and it is concluded that O(+), H charge exchange in the inner magnetosphere is sufficient to account for all the ENA O production.

Hsieh, K. C.

Comet Halley neutral gas density profile along the Vega 1 trajectory measured by NGE

Data from the Vega 1 permitted the determination of the total neutral gas density profile along the spacecraft trajectory. Discounting small fluctuations, the field ionization source instrument measured a density profile which varied approximately as the inverse radial distance squared. Data from the electron impact ionization instrument yielded a series of calibration points; e.g., the neutral density at 100,000 km is 10,000/cc. The combined data provide a calibrated total density profile, and imply a neutral production rate of 10 to the 30th power molecules/sec.

Curtis, C. C.

Neutral gas measurements of comet Halley from Vega 1

The neutral gas experiment (ING) aboard the Vega 1 spacecraft detected cometary gas within a distance of 60,000 km from the nucleus of comet Halley. A preliminary inspection of the data permits an analysis of the variation in neutral gas density. Fine structure was detected in the spatial disribution of lower-mass species.

Keppler, E.

Spacecraft mass spectrometer ion source employing field emission cathodes

An ion source that utilizes a pair of thin-film field emission cathodes to provide current for electric impact ionization is studied. The field emission cathodes are composed of microscopically small needle tips and an extraction electrode; the cathodes generate a 200-eV, 0.1-mA electron beam. The multistep process for the manufacturing of the field emission cathodes is examined. The operation of the ion source, which ionizes atoms and molecules that enter the mass spectrometer with a ram velocity of about 80 km/sec, is described.

Curtis, C. C.

Field ionization device used for measuring the pulse height defect of He/+/ in silicon

A neutral particle detector using field ionization and liquid-nitrogen-cooled solid state detectors has been developed to investigate the pulse height defect of low energy He(+) ions in silicon. The field ionization tip is fabricated from a short length of tungsten wire; a typical detector is of the surface-barrier Si type with a thin Au window and low capacitance (about 15 pF); the assembly is mounted in a cylindrical vacuum chamber which is pumped to about 10 to the -6th torr. As an example, pulse height distributions for He(+) and H(+) taken at tip bias of 25.7 kV are presented. The detected energy of the H and He ions are studied as a function of the actual energies of accelerated ions, for a detector having a gold front conducting surface layer of 32 micrograms/sq cm.

Curtis, C. C.

A field-ionization neutral detector - FIND

The field ionization neutral detector FIND operates according to the following principle: Neutral atoms are attracted toward the field ionization tips since they are polarized by the electric field of the tips. The atoms are singly ionized and repelled by the positive potential of the tips toward the detector situated behind a grid at ground potential. The ions deposit in the detector their kinetic energies, typically 26 keV, corresponding to the potential difference between the ionization region and the detector. Laboratory results show that FIND can have the resolution, sensitivities and durability required to perform in situ measurements of neutral H and He fluxes in interplanetary space, cometary halos and exospheres.

Curtis, C. C.

A field-ionization neutral-particle mass spectrometer

Description of laboratory model of a neutral-particle mass spectrometer that could make localized direct measurements of the neutral densities at 1 AU. Using a magnet that has a circular pole face 2.54 cm in diameter and a gap flux density of 8.0 kG, the following sensitivities were obtained for the various species: 10 to the 10th power counts per second per Torr for H2, 3 times 10 to the eighth power counts per second per Torr for He, and 2 times 10 to the 9th power counts per second per Torr for N2. Overall sensitivity may be increased through the use of electrostatic focusing elements between the ion source and the magnetic analyzer.

Curtis, C. C.