Search NASA⌕ Search

Engineering topics

Cushman, Priscilla B.

Publications and source records attributed to Cushman, Priscilla B..

Constraints on Lightly Ionizing Particles from CDMSlite

The Cryogenic Dark Matter Search low ionization threshold experiment (CDMSlite) achieved effcient detection of very small recoil energies in its germanium target, resulting in sensitivity to Lightly Ionizing Particles (LIPs) in a previously unexplored region of charge, mass, and velocity parameter space. We report first direct-detection limits on the vertical intensity of cosmogenically-produced LIPs with an electric charge smaller than e/(3x10^5), as well as the strongest limits for charge <= e/160, with a minimum vertical intensity of 1.36 x 10^-7 cm^-2s^-1sr^-1 at charge e/160. These results apply over a wide range of LIP masses (5 MeV/c^2 to 100 TeV/c^2) and cover a wide range of beta-gamma values (0.1--10^6), thus excluding non-relativistic LIPs with beta-gamma as small as 0.1 for the first time.

Alkhatib, I↗

Light Dark Matter Search with a High-Resolution Athermal Phonon Detector Operated Above Ground

We present limits on spin-independent dark matter-nucleon interactions using a 10.6 g silicon athermal phonon detector with a baseline energy resolution of 4.92 +/- 0.01 eV. This exclusion analysis sets the most stringent dark matter-nucleon cross-section limits for masses from 87--140 MeV/c^2 , with a raw exposure of 9.9 g d acquired at an above-ground facility. This work illustrates the scientic potential of athermal phonon sensors with eV-scale energy resolution for future dark matter searches.

Alkhatib, I↗

Constraints on dark photons and axionlike particles from the SuperCDMS Soudan experiment

We present an analysis of electron recoils in cryogenic germanium detectors operated during the SuperCDMS Soudan experiment. The data are used to set new constraints on the axioelectric coupling of axion-like particles and the kinetic mixing parameter of dark photons, assuming the respective species constitutes all of the galactic dark matter. This study covers the mass range from 40 eV/$c^2$ to 500 eV/$c^2$ for both candidates, excluding previously untested parameter space for masses below ~1 keV/$c^2$. For the kinetic mixing of dark photons, values below $10^{-15}$ are reached for particle masses around 100 eV/$c^2$; for the axioelectric coupling of axion-like particles, values below $10^{-12}$ are reached for particles with masses in the range of a few-hundred eV/$c^2$.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Search for Low-Mass Dark Matter with CDMSlite Using a Profile Likelihood Fit

The Cryogenic Dark Matter Search low ionization threshold experiment (CDMSlite) searches for interactions between dark matter particles and germanium nuclei in cryogenic detectors. The experiment has achieved a low energy threshold with improved sensitivity to low-mass (<10 GeV/c2) dark matter particles. We present an analysis of the final CDMSlite data set, taken with a different detector than was used for the two previous CDMSlite data sets. This analysis includes a data "salting" method to protect against bias, improved noise discrimination, background modeling, and the use of profile likelihood methods to search for a dark matter signal in the presence of backgrounds. We achieve an energy threshold of 70 eV and significantly improve the sensitivity for dark matter particles with masses between 2.5 and 10 GeV/c2 compared to previous analyses. We set an upper limit on the dark matter-nucleon scattering cross section in germanium of 5.4×10-42 cm2 at 5 GeV/c2, a factor of ~2.5 improvement over the previous CDMSlite result.

Agnese, R↗

New Results from the Search for Low-Mass Weakly Interacting Massive Particles with the CDMS low ionization Threshold Experiment

The CDMS low ionization threshold experiment (CDMSlite) uses cryogenic germanium detectors operated at a relatively high bias voltage to amplify the phonon signal in the search for weakly interacting massive particles (WIMPs). Results are presented from the second CDMSlite run with an exposure of 70 kg day, which reached an energy threshold for electron recoils as low as 56 eV. A fiducialization cut reduces backgrounds below those previously reported by CDMSlite.

New Results, Low-Mass, Mazzive Particles, CDMS Low↗

Dark matter effective field theory scattering in direct detection experiments

We examine the consequences of the effective field theory (EFT) of dark matter–nucleon scattering for current and proposed direct detection experiments. Exclusion limits on EFT coupling constants computed using the optimum interval method are presented for SuperCDMS Soudan, CDMS II, and LUX, and the necessity of combining results from multiple experiments in order to determine dark matter parameters is discussed. We demonstrate that spectral differences between the standard dark matter model and a general EFT interaction can produce a bias when calculating exclusion limits and when developing signal models for likelihood and machine learning techniques. We also discuss the implications of the EFT for the next-generation (G2) direct detection experiments and point out regions of complementarity in the EFT parameter space.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Maximum Likelihood Analysis of Low Energy CDMS II Germanium Data

We report on the results of a search for a Weakly Interacting Massive Particle (WIMP) signal in low-energy data of the Cryogenic Dark Matter Search experiment using a maximum likelihood analysis. A background model is constructed using GEANT4 to simulate the surface-event background from Pb210decay-chain events, while using independent calibration data to model the gamma background. Fitting this background model to the data results in no statistically significant WIMP component. In addition, we also perform fits using an analytic ad hoc background model proposed by Collar and Fields, who claimed to find a large excess of signal-like events in our data. Finally, we confirm the strong preference for a signal hypothesis in their analysis under these assumptions, but excesses are observed in both single- and multiple-scatter events, which implies the signal is not caused by WIMPs, but rather reflects the inadequacy of their background model.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

First Direct Limits on Lightly Ionizing Particles with Electric Charge Less than e / 6

While the standard model of particle physics does not include free particles with fractional charge, experimental searches have not ruled out their existence. We report results from the Cryogenic Dark Matter Search (CDMS II) experiment that give the first direct-detection limits for cosmogenically produced relativistic particles with electric charge lower than e / 6 . A search for tracks in the six stacked detectors of each of two of the CDMS II towers finds no candidates, thereby excluding new parameter space for particles with electric charges between e / 6 and e / 200 .

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for Low-Mass Weakly Interacting Massive Particles with SuperCDMS

We report a first search for weakly interacting massive particles (WIMPs) using the background rejection capabilities of SuperCDMS. An exposure of 577 kg-days was analyzed for WIMPs with mass < 30 GeV/c2, with the signal region blinded. Eleven events were observed after unblinding. We set an upper limit on the spin-independent WIMP-nucleon cross section of 1:2 10-42cm2 at 8 GeV/c2. This result is in tension with WIMP interpretations of recent experiments and probes new parameter space for WIMP-nucleon scattering for WIMP masses < 6 GeV/c2.

Search for Low-Mass WIMPs with SuperCDMS↗

Demonstration of Surface Electron Rejection with Interleaved Germanium Detectors for Dark Matter Searches

The SuperCDMS experiment in the Soudan Underground Laboratory searches for dark matter with a 9-kg array of cryogenic germanium detectors. Symmetric sensors on opposite sides measure both charge and phonons from each particle interaction, providing excellent discrimination between electron and nuclear recoils, and between surface and interior events. Furthermore, surface event rejection capabilities were tested with two 210 Pb sources producing ~130 beta decays/hr. We found that in ~800 live hours, no events leaked into the 8–115 keV signal region, giving upper limit leakage fraction 1.7 x 10 -5 at 90% C.L., corresponding to<0.6 surface event background in the future 200-kg SuperCDMS SNOLAB experiment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Low Background Materials and Assay: A Supplement to the Cosmic Frontier CF1 Summary.

Executive Summary The next generation of direct detection dark matter experiments will require stringent radiopurity in their target materials, internal instrumentation, and shielding components. A survey of major material assay facilities worldwide and of anticipated assay needs of generation 2 (G2) experiments indicate the current assay capability is marginally adequate in sensitivity and inadequate in throughput. High purity germanium (HPGe) gamma-ray assay has been the workhorse for material screening. It appears hundreds of samples will require screening at the limits of current achievable HPGe sensitivity. Mass spectroscopy methods and neutron activation analysis have demonstrated superior assay sensitivity in some specific cases. However, they are also currently throughput limited. In addition, both alpha/beta screening and radon emanation analysis at or beyond the current achievable sensitivity levels will be needed for dozens of samples. Experiments that follow G2 will have even more stringent material radiopurity specifications, exceeding current assay capabilities in both sensitivity and throughput. These screening needs must precede the commissioning of experiments by 3-5 years to inform design and quality control of components. Achieving the radiopurity goals of the next decade’s experiments will require investment in new techniques and tools to improve material assay sensitivity and throughput. Engineered low-background materials are a significant R&D expenditure, requiring developmental lead-time, and should benefit many end-user experiments. Reserving underground real estate for assay methods affected by cosmic rays (e.g. HPGe) and engineered radiopure materials activated by cosmic rays (e.g. electroformed copper) is judicious forward planning. In many cases, these spaces will require radon-suppressed sample preparation and material storage space. The above-mentioned survey of material assay facilities indicated very little development is taking place to improve sensitivity or throughput capability. In order to create the necessary infrastructure, it may help to form a consortium of low-background assay centers in the U.S that is managed by a scientific board with representatives from the community. This would provide for common use of existing screening facilities and a unified plan for new infrastructure and site development (see the Facilities White Paper). Such a loose organization already exists as AARM (Assay and Acquisition of Radiopure Materials), which is currently populating a community-wide materials database with published assay information. A more formal organization such as a Consortium is being actively investigated with DOE and NSF. Eventually, results of all screening performed in Consortium assay centers could be input directly to the open-access database, reducing duplication and providing for more efficient vendor selection.

Cooley-Sekula, Jodi↗