Search NASA⌕ Search

Engineering topics

D'Antonio, Michael

Publications and source records attributed to D'Antonio, Michael.

Compact and Low-cost Microinverter for Residential Systems

Concerns regarding climate change from the use of fossil fuels have expedited the growth of renewable energy sources. One such form of renewables, solar energy, is already playing and will continue to play a major role in meeting U.S clean energy targets. Expanding solar power usage in residential networks is a critical step in the decarbonization and clean electricity movement. To achieve a carbon-free grid by promoting solar power to the general public, an aggressive cost reduction in solar power systems is essential. The power density of the equipment used in the solar power system is necessary to solve the challenges of solar power installation. This project aims to research, explore, and assess the possibility of reducing the microinverter cost and volume to achieve the next generation microinverters (NGMs) targets for residential solar photovoltaic applications.

14 SOLAR ENERGY↗

Optimal Modulation and DM Filter Design for a High Switching Frequency Single-Stage Microinverter

This paper presents an optimal modulation and systematic filter design approach for a single-stage dual-active-bridge (DAB) based dc-ac microinverter to achieve improved differential-mode (DM) noise performance for electromagnetic interference (EMI) tests. As DM filters contribute significantly to the overall converter volume, the main objective of this work is to leverage the degrees of freedom in the DAB converters to effectively attenuate the EMI noise. In addition, the DM filter design method needs to ensure near unity power factor converter operation. To achieve these targets, this paper analyzes three modulation strategies based on fixed or variable switching frequency operation where the different control modulation variables are varied to find the simulated DM noise spectrum. Based on the required DM attenuation, a constrained optimization problem is formulated to determine minimal DM filter parameters. Simulation results show that a spread spectrum approach with variable switching frequency is shown to minimize the DM EMI attenuation effort by spreading the noise profile. A fully GaN 400 W hardware prototype demonstrated the spread-sprectrum approach.

14 SOLAR ENERGY↗

Comparison of CCM- and CRM-Based Boost Parallel Active Power Decoupler for PV Microinverter

Single-phase inverter or rectifier systems often make use of an active power decoupler (APD) to balance the mismatch between constant dc power and fluctuating ac power. This article deals with the comparison of continuous conduction mode (CCM) and critical conduction mode (CRM) operation-based design of a parallel boost-type APD for photovoltaic microinverter applications. From a design perspective, multiobjective analysis of efficiency, volume, and cost is explored within a decision space including planar inductors, gallium nitride based devices, film capacitors, switching frequency, and modulation (CCM vs. CRM). The theoretical study analyzes all possible design configurations within CCM and CRM and identifies Pareto-optimal designs, from which the selected CRM design can achieve reduced system volume and lower cost with the use of smaller inductor core, while operating with similar California Energy Commission efficiency drop as the selected CCM design. From a control perspective, a pulsewidth modulation based control strategy is proposed to implement closed-loop CRM modulation that does not rely on zero-crossing detection. Furthermore, closed-loop systems are designed for the optimal CCM and CRM realizations, and the final system characteristics are compared. Experimental results, obtained using two separate 40-V, 400-W hardware prototypes for CCM and CRM, are presented to verify the analyses.

42 ENGINEERING↗

Planar Transformer With Asymmetric Integrated Leakage Inductance Using Horizontal Air Gap

This article presents a novel planar-based transformer winding and core structure with controllable leakage inductance generation for integrated magnetics applications. As a result of limitations in integrated magnetics from the literature, a new approach is proposed utilizing semi-interleaved windings and controllable leakage via a leakage flux core leg featuring a horizontal air gap. Here, the proposed transformer design is analyzed via detailed reluctance modeling to determine closed-form equations for the magnetizing and asymmetrically distributed leakage inductances. Next, a genetic-algorithm-based multiobjective design optimization problem is developed, seeking to minimize the core and winding losses of the proposed transformer subject to a set of parametric and geometric constraints in a dc-ac dual-active-bridge topology for microinverter applications. The optimization was extended to include other integrated magnetic structures from the literature, where it is determined that the proposed transformer is superior from the perspectives of efficiency, footprint area, and parasitic capacitance. Based on the results of the optimization analysis, two designs with theoretical transformer California Energy Commission (CEC) efficiency drops (i.e., CEC efficiency reduction specifically due to the transformer loss mechanisms) of 1.19% and 0.83% were fabricated and evaluated for electrical and thermal performance in the proposed 40 V, 400 W microinverter.

42 ENGINEERING↗

Improved Frequency-Domain Steady-State Modeling of the Dual-Active-Bridge Converter Considering Finite ZVS Transition Time Effects

This article presents an improved analytical modeling (IAM) approach for the dual-active-bridge (DAB) converter in the frequency-domain. Specifically, finite transition times are incorporated into the improved modeling that are significant in DAB converters operated at high frequency. The IAM approach is first motivated by comparing traditional frequency-domain modeling against realistic simulation results in LTspice. Next, the IAM approach is mathematically developed in an iterative fashion, where the conventional frequency-domain approach is used as the initialization of the operational behavior of the converter. Subsequent iterations of the IAM algorithm incorporate finite rise- and falltimes of device output capacitances based on detailed switching behavior analyses, which may considerably perturb the desired modulation parameters (i.e., phase shift and zero states). While the initially proposed IAM approach demonstrates advantages over ideal modeling, it is still shown to exhibit errors when applied to device transitions with significant nonlinearity in parasitic output capacitance. To account for this, a three-slope approximation to the switching transition is then motivated and developed, which enables significantly improved steady-state prediction accuracy. Simulation and experimental results confirm unacceptable inaccuracies associated with the conventional frequency-domain modeling across a wide range of operating conditions, alongside enhanced accuracy provided by the proposed modeling approach.

14 SOLAR ENERGY↗

Design Optimization for Weighted Conduction Loss Minimization in a Dual-Active-Bridge-Based PV Microinverter

This manuscript presents a harmonic-superposition based frequency-domain approach for analysis and optimal design of a single-stage DAB-based DC-AC converter used in low-voltage DC to high voltage AC applications, such as PV microinverter. Specifically, two topological variations and correspondingly different modulation strategies involving up to four control variables (three phase shifts and switching frequency) are analyzed. Optimal trajectories of control variables are determined that result in minimized transformer RMS current at a given average power, while enforcing near-uniform ZVS. To make the design process holistic, an outer optimization loop is used to determine optimal values for the power transfer inductance (integrated as the transformer’s leakage inductance) and turns ratio, which minimize the weighted-average conduction loss contribution to the microinverter’s CEC efficiency. Based on the optimization analyses, a 400 W microinverter prototype is built and experimental results at one operating point are presented, achieving a measured efficiency of 92.8%.

14 SOLAR ENERGY↗

CCM vs. CRM Design Optimization of a Boost-derived Parallel Active Power Decoupler for Microinverter Applications

Single-phase inverter or rectifier systems often make use of an auxiliary active power decoupler (APD) to balance the mismatch between steady DC power and fluctuating AC power. This paper deals with efficiency and size optimization of a parallel boost-type APD circuit for PV microinverter applications. Specifically, design of an eGaNFET-based, 400 W APD circuit, employing planar inductor and operating in either continuous conduction mode (CCM) or critical conduction mode (CRM) is considered. Available design variables including inductance value, inductor core geometry, capacitor voltage, switching frequency, and modulation scheme (CCM vs. CRM) are explored to identify Pareto-optimal configurations, which can achieve low California Energy Commission (CEC) efficiency drop while also reducing the footprint area of the inductor. The theoretical study predicts that the optimal CRM design can achieve 37% reduced inductor size, while operating with similar efficiency drop, compared to the optimal CCM design. Experimental results, obtained using two separate 40 V, 400 W hardware prototypes for CCM and CRM, are presented to verify the analyses.

14 SOLAR ENERGY↗