Search NASA⌕ Search

Engineering topics

Daniel G. Bae

Publications and source records attributed to Daniel G. Bae.

Delta Method Application for the Correlation of IR Detector Thermal Parasitic Loads with Statistically Accurate Results

The Linear Etalon Imaging Spectral Array (LEISA) is a cryogenic IR detector that is passively cooled below 110K. LEISA is part of the L’Ralph instrument, which is going on the Lucy mission, with planned flyby’s of the Trojan asteroids around 5.5 AU. One of the primary thermal challenges is to successfully quantify each significant parasitic heat flow value with statistical certainty.Simulation of flight-like thermal environments and correlation of thermal models is an important part of this challenge, which can be critical for thermally sensitive systems such as cryogenic detectors that are passively cooled. It is common practice during TVAC to achieve several thermal balance points and then to correlate several design variables in order to achieve the closest match to all balance points tested. This approach lends itself to high levels of uncertainty in the correlated values due to the cumulative effect of absolute temperature uncertainty and differences between the sensors used for the measurement. Accuracy can be improved with the use of more accurate sensors, by calibrating all sensors with respect to each other, and by using Zero-Q methodologies, all of which add cost and complexity to the test.The Delta Method uses the difference in temperature caused by the changes in the boundary conditions to calculate heat flows and/or thermal resistances across temperature differentials. This eliminates the problem of high uncertainties with absolute temperature measurements, and yields statistically accurate results down to the sensor resolution of 1mK at < 100K, by taking the sensor’s calibration errors out of the equation. During testing, this method relies on parametric variations around an initial balance point, by varying the boundary conditions of the different parasitic heat sources. The Delta Method, as well as its application on the LEISA thermal test, will be discussed in detail.

Daniel G. Bae↗

Performance of the Dragonfly Mass Spectrometer (DraMS) Programmable UV Laser Source Engineering Test Unit (ETU)

NASA’s Dragonfly mission will sample surface materials from multiple sites on Saturn’s largest moon, Titan, in exploration of its potential for prebiotic chemistry. We report on the performance of our short-pulsed UV laser transmitter, developed for the Dragonfly’s on-board Mass Spectrometer (DraMS). Our engineering test unit (ETU) has completed flight qualification and demonstrated its operational science requirements, such that the final flight unit build can begin. The Titan Hydrocarbon Analysis Nanosecond Optical Source (THANOS) ETU laser produces 266 nm laser pulses at programmable energy levels in order to create high resolution laser desorption mass spectrometry (LDMS) measurements. The laser operates in short bursts of 1-50 pulses, each at < 2 ns pulse width, at a 100 Hz repetition rate. Creating a sealed Titanium unit, capable of operation on the extreme environment of Titan’s surface was a major engineering challenge. The laser successfully demonstrated its ability to meet all operational requirements in terms of pulse energy, beam pointing on target and repeatability even after extensive environmental testing.

Matthew Mullin↗

Coupling a Computational Fluid Dynamics Model to a Spacecraft Thermal System Model for the DraMS Instrument Thermal Analysis

The Dragonfly Mass Spectrometer (DraMS) is an instrument on the Dragonfly mission, which will spend 7 years in deep space cruise before landing and operating on the surface of Titan. Vacuum thermal analyses are required for deep space cruise, and convection analyses are required for the Titan surface operations. Model exchanges across multiple thermal teams are needed for all phases of the mission. For DraMS, Thermal Desktop® (TD) has been the main thermal analytical tool of choice due to its capability in modeling complex thermal systems with relatively low computational power and for its availability across thermal teams. However, TD does not have computational fluid dynamics (CFD) capability and struggles to accurately capture complex convective behavior. DraMS has fans operating in tandem and gas flow behaviors are not easily predicted due to its complex flow paths. CFD software, such as Fluent, can model and predict such complex flow behaviors, but CFD models are computationally expensive, and its workflow processes are not tailored towards simulating large and complex systems. Therefore, a coupled modeling approach was chosen for DraMS: A TD model was used for simulating all the conductive, radiative, and source terms, while a Fluent CFD model was added on, as needed, to the TD model to provide the convective boundary conditions using the System Coupling software. The coupling software allows the TD and Fluent models to communicate data and arrive at a co-solved and co-converged solution. Furthermore, Thermal Iso-value Exchange (TIE) method was developed to facilitate and improve the TD-Fluent data exchange process. This paper will discuss the analytical studies that were done to verify the accuracy and usability of the coupled approach and the challenges associated, which lead to the development of the TIE approach. DraMS thermal design and co-solved analysis results will also be discussed.

Heat transfer↗