Progress Report on the Spacecraft Atmosphere Monitor’s Development Model

The Spacecraft Atmosphere Monitor (S.A.M.) is a miniature gas chromatograph (GC) mass spectrometer (MS) intended for assessing trace volatile organic compounds and the major constituents in the atmosphere of present (the International Space Station) and future crewed spacecraft. As such, S.A.M. will continuously sample concentrations of major air constituents (CH4, H2O, N2, O2, and CO2) and report results in two-second intervals. The S.A.M. is a technology demonstration planned to launch in 2018 and we report here on recent developments taking place in building a testbed and development model of the instrument. The S.A.M. is mechanically designed to operate under hi-G loads present during launch events and can operate at sub-atmospheric pressures relevant to extra-vehicular activities. Total instrument mass is projected at 9.5 kg with power consumption estimated at 35 W. The S.A.M. instrument will provide on-demand reporting on trace volatile organic compounds (VOC) at ppm to ppb levels of 40+ species relevant for astronaut health.

Darrach, M.↗

Mass Spectra Deconvolution of Gaseous Mixtures Containing Volatile Organic Compounds

The Spacecraft Atmosphere Monitor (S.A.M.) analyzes all gaseous pollutants in the 1-150Th mass-to-charge range based on their positive-ion mass spectra. Of particular interest is the Trace Gas Analysis (TGA) mode of operation in which S.A.M detects minute amounts of volatile organic compounds (VOC). Pollutant component of the ambient air is sampled on demand in twenty full mass spectra per second. All spectra is accumulated in two-second intervals by an on-board Field Programmable Gate Arrays (FPGA) unit. Mass spectra represents the number of detected fragment ions in a given mass-to-charge ratio channel. Electron impact ionization of neutral molecules results in creation of numerous fragment ions and most of organic compounds will contribute several identical fragments. Despite the presence of these molecular isobars, we developed the deconvolution algorithm capable of identifying target species based on their characteristic fragmentation patterns. We investigate the efficiency of deconvolution algorithm as a function of mass resolution with which mass spectrum is acquired. Higher the mass resolution, better the chances are to distinguish between stereoisomers using their fragmentation propensities, but also results in higher data volumes to be processed by a set of small footprint software stacks hosted by an on-board computer. Finding the balance between deconvolution accuracy and generated data volume under time constrains and limited computing resources is the main topic of this study.

Darrach, M.↗

Miniaturized GC/MS instrumentation for in situ measurements: micro gas chromatography coupled with miniature quadrupole array and paul ion trap mass spectrometers

Miniaturized chemical instrumentation is needed for in situ measurements in planetary exploration and other spaceflight applications where factors such as reduction in payload requirements and enhanced robustness are important. In response to this need, we are 'continuing to develop miniaturized GC/MS instrumentation which combines chemical separations by gas chromatography (GC) with mass spectrometry (MS) to provide positive identification of chemical compounds in complex mixtures of gases, such as those found in the International Space Station's cabin atmosphere. Our design approach utilizes micro gas chromatography components coupled with either a miniature quadrupole mass spectrometer array (QMSA) or compact, high-resolution Paul ion trap.

GC/MC miniature mass spectrometry MEMS↗