How Advances in Imaging Will Affect Precision Radiation Oncology

Radiation oncology is 1 of the most structured disciplines in medicine. It is of a highly technical nature with reliance on robotic systems to deliver intervention, engagement of diverse expertise, and early adoption of digital approaches to optimize and execute the application of this highly effective cancer treatment. As a localized intervention, the dependence on sensitive, specific, and accurate imaging to define the extent of disease, its heterogeneity, and adjacency to normal tissues directly affects the therapeutic ratio. Image-based in vivo temporal monitoring of the response to treatment enables adaptation and further affects the therapeutic ratio. Thus, more precise intervention will enable fractionation schedules that better interoperate with advances such as immunotherapy. In the data set–rich era that promises precision and personalized medicine, the radiation oncology field will integrate these new data into highly protocoled pathways of care that begin with multimodality prediction and enable patient-specific adaptation of therapy based on quantitative measures of the individual's dose–volume temporal trajectory and midtherapy predictions of response. In addition to advancements in computed tomography imaging, emerging technologies, such as ultra-high-field magnetic resonance and molecular imaging will bring new information to the design of treatments. Next-generation image guided radiation therapy systems will inject high specificity and sensitivity data and stimulate adaptive replanning. In addition, a myriad of pre- and peritherapeutic markers derived from advances in molecular pathology (eg, tumor genomics), automated and comprehensive imaging analytics (eg, radiomics, tumor microenvironment), and many other emerging biomarkers (eg, circulating tumor cell assays) will need to be integrated to maximize the benefit of radiation therapy for an individual patient. We present a perspective on the promise and challenges of fully exploiting imaging data in the pursuit of personalized radiation therapy, drawing from the presentations and broader discussions at the 2016 American Society of Therapeutic Radiation Oncology–National Cancer Institute workshop on Precision Medicine in Radiation Oncology (Bethesda, MD).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric Predictors of Patient-Reported Xerostomia and Dysphagia With Deintensified Chemoradiation Therapy for HPV-Associated Oropharyngeal Squamous Cell Carcinoma

Purpose/Objective(s): To estimate the association between different dose-volume metrics of the salivary glands and pharyngeal constrictors with patient reported severity of xerostomia/dysphagia in the setting of deintensified chemoradiation therapy (CRT). Methods and Materials: Forty-five patients were treated on a phase 2 study assessing the efficacy of deintensified CRT for favorable-risk, HPV-associated oropharyngeal squamous cell carcinoma. Patients received 60 Gy intensity modulated radiation therapy with concurrent weekly cisplatin (30 mg/m{sup 2}), and reported the severity of their xerostomia/dysphagia (before and after treatment) using the patient-reported outcome version of the Common Terminology Criteria for Adverse Events (CTCAE) (PRO-CTCAE). Individual patient dosimetric data of the contralateral parotid and submandibular glands and pharyngeal constrictors were correlated with changes in PRO-CTCAE severity. A change in severity (from baseline) of ≥2 was considered clinically meaningful. Associations between dose-volume metrics and patient outcomes were assessed with receiver operating characteristic (ROC) curve and logistic regression model. Results: Six months after CRT, patients reporting <2 change in xerostomia severity (n=14) had an average D{sub mean} = 22 ± 9 Gy to the sum of the contralateral glands (parotid + submandibular) compared with the patients reporting ≥2 change (n=21), who had an average D{sub mean} = 34 ± 8 Gy. V15 to V55 for the combined contralateral glands showed the strongest association with xerostomia (area under the curve [AUC] = 0.83-0.86). Based on the regression analysis, a 20% risk of toxicity was associated with V15 = 48%, V25 = 30%, and D{sub mean}=21 Gy. Six months after CRT, patients reporting <2 change in dysphagia severity (n=26) had an average V55 = 76 ± 13 (%) to the superior pharyngeal constrictor compared with the patients reporting ≥2 change in severity (n=9), who had average V55 = 89 ± 13 (%). V55to V60 had the strongest association with dysphagia (AUC = 0.70-0.75). Based on the regression analysis, a 20% risk of toxicity was associated with V55 = 78%, V60 = 40%. The findings at 12 months were similar. Conclusions: After deintensified CRT, the rate of patient-reported xerostomia/dysphagia appears to be associated with the V15 of the combined contralateral salivary glands and V55 to V60 of the superior pharyngeal constrictors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Simple Factors Associated With Radiation-Induced Lung Toxicity After Stereotactic Body Radiation Therapy of the Thorax: A Pooled Analysis of 88 Studies

Purpose: To study the risk factors for radiation-induced lung toxicity (RILT) after stereotactic body radiation therapy (SBRT) of the thorax. Methods and Materials: Published studies on lung toxicity in patients with early-stage non–small cell lung cancer (NSCLC) or metastatic lung tumors treated with SBRT were pooled and analyzed. The primary endpoint was RILT, including pneumonitis and fibrosis. Data of RILT and risk factors were extracted from each study, and rates of grade 2 to 5 (G2+) and grade 3 to 5 (G3+) RILT were computed. Patient, tumor, and dosimetric factors were analyzed for their correlation with RILT. Results: Eighty-eight studies (7752 patients) that reported RILT incidence were eligible. The pooled rates of G2+ and G3+ RILT from all 88 studies were 9.1% (95% confidence interval [CI]: 7.15-11.4) and 1.8% (95% CI: 1.3-2.5), respectively. The median of median tumor sizes was 2.3 (range, 1.4-4.1) cm. Among the factors analyzed, older patient age (P=.044) and larger tumor size (the greatest diameter) were significantly correlated with higher rates of G2+ (P=.049) and G3+ RILT (P=.001). Patients with stage IA versus stage IB NSCLC had significantly lower risks of G2+ RILT (8.3% vs 17.1%, odds ratio = 0.43, 95% CI: 0.29-0.64, P<.0001). Among studies that provided detailed dosimetric data, the pooled analysis demonstrated a significantly higher mean lung dose (MLD) (P=.027) and V20 (P=.019) in patients with G2+ RILT than in those with grade 0 to 1 RILT. Conclusions: The overall rate of RILT is relatively low after thoracic SBRT. Older age and larger tumor size are significant adverse risk factors for RILT. Lung dosimetry, specifically lung V20 and MLD, also significantly affect RILT risk.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Phase 1 Dose Escalation Study of Accelerated Radiation Therapy With Concurrent Chemotherapy for Locally Advanced Lung Cancer

Purpose: To determine the maximum tolerated dose of radiation therapy (RT) given in an accelerated fashion with concurrent chemotherapy using intensity modulated RT. Methods and Materials: Patients with locally advanced lung cancer (non-small cell and small cell) with good performance status and minimal weight loss received concurrent cisplatin and etoposide with RT. Intensity modulated RT with daily image guidance was used to facilitate esophageal avoidance and delivered using 6 fractions per week (twice daily on Fridays with a 6-hour interval). The dose was escalated from 58 Gy to a planned maximum dose of 74 Gy in 4 Gy increments in a standard 3 + 3 trial design. Dose-limiting toxicity (DLT) was defined as acute grade 3-5 nonhematologic toxicity attributed to RT. Results: A total of 24 patients were enrolled, filling all dose cohorts, all completing RT and chemotherapy as prescribed. Dose-limiting toxicity occurred in 1 patient at 58 Gy (grade 3 esophagitis) and 1 patient at 70 Gy (grade 3 esophageal fistula). Both patients with DLTs had large tumors (12 cm and 10 cm, respectively) adjacent to the esophagus. Three additional patients were enrolled at both dose cohorts without further DLT. In the final 74-Gy cohort, no DLTs were observed (0 of 6). Conclusions: Dose escalation and acceleration to 74 Gy with intensity modulated RT and concurrent chemotherapy was tolerable, with a low rate of grade ≥3 acute esophageal reactions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Assessing Cardiac Injury in Mice With Dual Energy-MicroCT, 4D-MicroCT, and MicroSPECT Imaging After Partial Heart Irradiation

Purpose: To develop a mouse model of cardiac injury after partial heart irradiation (PHI) and to test whether dual energy (DE)-microCT and 4-dimensional (4D)-microCT can be used to assess cardiac injury after PHI to complement myocardial perfusion imaging using micro-single photon emission computed tomography (SPECT). Methods and Materials: To study cardiac injury from tangent field irradiation in mice, we used a small-field biological irradiator to deliver a single dose of 12 Gy x-rays to approximately one-third of the left ventricle (LV) of Tie2Cre; p53{sup FL/+} and Tie2Cre; p53{sup FL/−} mice, where 1 or both alleles of p53 are deleted in endothelial cells. Four and 8 weeks after irradiation, mice were injected with gold and iodinated nanoparticle-based contrast agents, and imaged with DE-microCT and 4D-microCT to evaluate myocardial vascular permeability and cardiac function, respectively. Additionally, the same mice were imaged with microSPECT to assess myocardial perfusion. Results: After PHI with tangent fields, DE-microCT scans showed a time-dependent increase in accumulation of gold nanoparticles (AuNp) in the myocardium of Tie2Cre; p53{sup FL/−} mice. In Tie2Cre; p53{sup FL/−} mice, extravasation of AuNp was observed within the irradiated LV, whereas in the myocardium of Tie2Cre; p53{sup FL/+} mice, AuNp were restricted to blood vessels. In addition, data from DE-microCT and microSPECT showed a linear correlation (R{sup 2} = 0.97) between the fraction of the LV that accumulated AuNp and the fraction of LV with a perfusion defect. Furthermore, 4D-microCT scans demonstrated that PHI caused a markedly decreased ejection fraction, and higher end-diastolic and end-systolic volumes, to develop in Tie2Cre; p53{sup FL/−} mice, which were associated with compensatory cardiac hypertrophy of the heart that was not irradiated. Conclusions: Our results show that DE-microCT and 4D-microCT with nanoparticle-based contrast agents are novel imaging approaches complementary to microSPECT for noninvasive assessment of the change in myocardial vascular permeability and cardiac function of mice in whom myocardial injury develops after PHI.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

On the Need for Comprehensive Validation of Deformable Image Registration, Investigated With a Novel 3-Dimensional Deformable Dosimeter

Purpose: To introduce and evaluate a novel deformable 3-dimensional (3D) dosimetry system (Presage-Def/Optical-CT) and its application toward investigating the accuracy of dose deformation in a commercial deformable image registration (DIR) package. Methods and Materials: Presage-Def is a new dosimetry material consisting of an elastic polyurethane matrix doped with radiochromic leuco dye. Radiologic and mechanical properties were characterized using standard techniques. Dose-tracking feasibility was evaluated by comparing dose distributions between dosimeters irradiated with and without 27% lateral compression. A checkerboard plan of 5-mm square fields enabled precise measurement of true deformation using 3D dosimetry. Predicted deformation was determined from a commercial DIR algorithm. Results: Presage-Def exhibited a linear dose response with sensitivity of 0.0032 ΔOD/(Gy∙cm). Mass density is 1.02 g/cm{sup 3}, and effective atomic number is within 1.5% of water over a broad (0.03-10 MeV) energy range, indicating good water-equivalence. Elastic characteristics were close to that of liver tissue, with Young's modulus of 13.5-887 kPa over a stress range of 0.233-303 kPa, and Poisson's ratio of 0.475 (SE, 0.036). The Presage-Def/Optical-CT system successfully imaged the nondeformed and deformed dose distributions, with isotropic resolution of 1 mm. Comparison with the predicted deformed 3D dose distribution identified inaccuracies in the commercial DIR algorithm. Although external contours were accurately deformed (submillimeter accuracy), volumetric dose deformation was poor. Checkerboard field positioning and dimension errors of up to 9 and 14 mm, respectively, were identified, and the 3D DIR-deformed dose γ passing rate was only γ{sub 3%/3} {sub mm} = 60.0%. Conclusions: The Presage-Def/Optical-CT system shows strong potential for comprehensive investigation of DIR algorithm accuracy. Substantial errors in a commercial DIR were found in the conditions evaluated. This work highlights the critical importance of careful validation of DIR algorithms before clinical implementation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Volumetric-Modulated Arc Therapy: Effective and Efficient End-to-End Patient-Specific Quality Assurance

Purpose: To explore an effective and efficient end-to-end patient-specific quality-assurance (QA) protocol for volumetric modulated arc radiotherapy (VMAT) and to evaluate the suitability of a stationary radiotherapy QA device (two-dimensional [2D] ion chamber array) for VMAT QA. Methods and Materials: Three methods were used to analyze 39 VMAT treatment plans for brain, spine, and prostate: ion chamber (one-dimensional absolute, n = 39), film (2D relative, coronal/sagittal, n = 8), and 2D ion chamber array (ICA, 2D absolute, coronal/sagittal, n = 39) measurements. All measurements were compared with the treatment planning system dose calculation either via gamma analysis (3%, 3- to 4-mm distance-to-agreement criteria) or absolute point dose comparison. The film and ion chamber results were similarly compared with the ICA measurements. Results: Absolute point dose measurements agreed well with treatment planning system computed doses (ion chamber: median deviation, 1.2%, range, -0.6% to 3.3%; ICA: median deviation, 0.6%, range, -1.8% to 2.9%). The relative 2D dose measurements also showed good agreement with computed doses (>93% of pixels in all films passing gamma, >90% of pixels in all ICA measurements passing gamma). The ICA relative dose results were highly similar to those of film (>90% of pixels passing gamma). The coronal and sagittal ICA measurements were statistically indistinguishable by the paired t test with a hypothesized mean difference of 0.1%. The ion chamber and ICA absolute dose measurements showed a similar trend but had disparities of 2-3% in 18% of plans. Conclusions: After validating the new VMAT implementation with ion chamber, film, and ICA, we were able to maintain an effective yet efficient patient-specific VMAT QA protocol by reducing from five (ion chamber, film, and ICA) to two measurements (ion chamber and single ICA) per plan. The ICA (Matrixx Registered-Sign , IBA Dosimetry) was validated for VMAT QA, but ion chamber measurements are recommended for absolute dose comparison until future developments correct the ICA angular dependence.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Polymorphism Within the Promoter of the TGF{beta}1 Gene Is Associated With Radiation Sensitivity Using an Objective Radiologic Endpoint

Purpose: To evaluate whether single nucleotide polymorphisms (SNPs) in the transforming growth factor-{beta}1 (TGF{beta}1) gene are associated with radiation sensitivity using an objective radiologic endpoint. Methods and Materials: Preradiation therapy and serial postradiation therapy single photon emission computed tomography (SPECT) lung perfusion scans were obtained in patients undergoing treatment for lung cancer. Serial blood samples were obtained to measure circulating levels of TGF{beta}1. Changes in regional perfusion were related to regional radiation dose yielding a patient-specific dose-response curve, reflecting the patient's inherent sensitivity to radiation therapy. Six TGF{beta}1 SNPs (-988, -800, -509, 869, 941, and 1655) were assessed using high-resolution melting assays and DNA sequencing. The association between genotype and slope of the dose-response curve, and genotype and TGF{beta}1 ratio (4-week/preradiation therapy), was analyzed using the Kruskal-Wallis test. Results: 39 white patients with preradiation therapy and {>=}6-month postradiation therapy SPECT scans and blood samples were identified. Increasing slope of the dose-response curve was associated with the C(-509)T SNP (p = 0.035), but not the other analyzed SNPs. This SNP was also associated with higher TGF{beta}1 ratios. Conclusions: This study suggests that a polymorphism within the promoter of the TGF{beta}1 gene is associated with increased radiation sensitivity (defined objectively by dose-dependent changes in SPECT lung perfusion).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Commissioning a small-field biological irradiator using point, 2D, and 3D dosimetry techniques

Purpose: To commission a small-field biological irradiator, the XRad225Cx from Precision x-Ray, Inc., for research use. The system produces a 225 kVp x-ray beam and is equipped with collimating cones that produce both square and circular radiation fields ranging in size from 1 to 40 mm. This work incorporates point, 2D, and 3D measurements to determine output factors (OF), percent-depth-dose (PDD) and dose profiles at multiple depths. Methods: Three independent dosimetry systems were used: ion-chambers (a farmer chamber and a micro-ionisation chamber), 2D EBT2 radiochromic film, and a novel 3D dosimetry system (DLOS/PRESAGE registered ). Reference point dose rates and output factors were determined from in-air ionization chamber measurements for fields down to {approx}13 mm using the formalism of TG61. PDD, profiles, and output factors at three separate depths (0, 0.5, and 2 cm), were determined for all field sizes from EBT2 film measurements in solid water. Several film PDD curves required a scaling correction, reflecting the challenge of accurate film alignment in very small fields. PDDs, profiles, and output factors were also determined with the 3D DLOS/PRESAGE registered system which generated isotropic 0.2 mm data, in scan times of 20 min. Results: Surface output factors determined by ion-chamber were observed to gradually drop by {approx}9% when the field size was reduced from 40 to 13 mm. More dramatic drops were observed for the smallest fields as determined by EBT{approx}18% and {approx}42% for the 2.5 mm and 1 mm fields, respectively. PRESAGE registered and film output factors agreed well for fields <20 mm (where 3D data were available) with mean deviation of 2.2% (range 1%-4%). PDD values at 2 cm depth varied from {approx}72% for the 40 mm field, down to {approx}55% for the 1 mm field. EBT and PRESAGE registered PDDs agreed within {approx}3% in the typical therapy region (1-4 cm). At deeper depths the EBT curves were slightly steeper (2.5% at 5 cm). These results indicate good overall consistency between ion-chamber, EBT2 and PRESAGE registered measured OFs, PDDs, and profiles. Conclusions: The combination of independent 2D and 3D measurements was found to be valuable to ensure accurate and comprehensive commissioning. Film measurements were time consuming and challenging due to the difficulty of film alignment in small fields. PRESAGE registered 3D measurements were comprehensive and efficient, because alignment errors are negligible, and all parameters for multiple fields could be obtained from a single dosimeter and scan. However, achieving accurate superficial data (within 4 mm) is not yet feasible due to optical surface artifacts.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Biologically Effective Dose (BED) Correlation With Biochemical Control After Low-Dose Rate Prostate Brachytherapy for Clinically Low-Risk Prostate Cancer

Purpose: To assess the correlation of postimplant dosimetric quantifiers with biochemical control of prostate cancer after low-dose rate brachytherapy. Methods and Materials: The biologically effective dose (BED), dose in Gray (Gy) to 90% of prostate (D{sub 90}), and percent volume of the prostate receiving 100% of the prescription dose (V{sub 100}) were calculated from the postimplant dose-volume histogram for 140 patients undergoing low-dose rate prostate brachytherapy from 1997 to 2003 at Durham Regional Hospital and the Durham VA Medical Center (Durham, NC). Results: The median follow-up was 50 months. There was a 7% biochemical failure rate (10 of 140), and 91% of patients (127 of 140) were alive at last clinical follow-up. The median BED was 148 Gy (range, 46-218 Gy). The median D{sub 90} was 139 Gy (range, 45-203 Gy). The median V{sub 100} was 85% (range, 44-100%). The overall 5-year biochemical relapse-free survival (bRFS) rate was 90.1%. On univariate Cox proportional hazards modeling, no pretreatment characteristic (Gleason score sum, age, baseline prostate-specific antigen, or clinical stage) was predictive of bRFS. The BED, D{sub 90}, and V{sub 100} were all highly correlated (Pearson coefficients >92%), and all were strongly correlated with bRFS. Using the Youden method, we identified the following cut points for predicting freedom from biochemical failure: D{sub 90} >= 110 Gy, V{sub 100} >= 74%, and BED >= 115 Gy. None of the covariates significantly predicted overall survival. Conclusions: We observed significant correlation between BED, D{sub 90}, and V{sub 100} with bRFS. The BED is at least as predictive of bRFS as D{sub 90} or V{sub 100}. Dosimetric quantifiers that account for heterogeneity in tumor location and dose distribution, tumor repopulation, and survival probability of tumor clonogens should be investigated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A role for biological optimization within the current treatment planning paradigm

Purpose: Biological optimization using complication probability models in intensity modulated radiotherapy (IMRT) planning has tremendous potential for reducing radiation-induced toxicity. Nevertheless, biological optimization is almost never clinically utilized, probably because of clinician confidence in, and familiarity with, physical dose-volume constraints. The method proposed here incorporates biological optimization after dose-volume constrained optimization so as to improve the dose distribution without detrimentally affecting the important reductions achieved by dose-volume optimization (DVO). Methods: Following DVO, the clinician/planner first identifies ''fixed points'' on the target and organ-at-risk (OAR) dose-volume histograms. These points represent important DVO plan qualities that are not to be violated within a specified tolerance. Biological optimization then maximally reduces a biological metric (illustrated with equivalent uniform dose (EUD) in this work) while keeping the fixed dose-volume points within tolerance limits, as follows. Incremental fluence adjustments are computed and applied to incrementally reduce the OAR EUDs while approximately maintaining the fixed points. This process of incremental fluence adjustment is iterated until the fixed points exceed tolerance. At this juncture, remedial fluence adjustments are computed and iteratively applied to bring the fixed points back within tolerance, without increasing OAR EUDs. This process of EUD reduction followed by fixed-point correction is repeated until no further EUD reduction is possible. The method is demonstrated in the context of a prostate cancer case and olfactory neuroblastoma case. The efficacy of EUD reduction after DVO is evaluated by comparison to an optimizer with purely biological (EUD) OAR objectives. Results: For both cases, EUD reduction after DVO additionally reduced doses, especially high doses, to normal organs. For the prostate case, bladder/rectum EUDs were reduced (after DVO) by 5.0%/3.9%, and highest doses were reduced by 4.6%/7.8%. The optimization with purely biological OAR objectives achieved bladder/rectal EUDs that were 7.4%/3.1% lower than from DVO, but only reduced highest doses by 1.4%/0.7%. In the olfactory neuroblastoma case, the target was closely surrounded by the eyes, optic nerves, chiasm, and brainstem. In one of the scenarios studied, the eyes, optic nerves, and chiasm were targeted for EUD reduction after DVO. EUD to the left eye, right eye, left optic nerve, right optic nerve, and chiasm were reduced by 7.0%, 5.7%, 4.7%, 4.1%, and 0.6%, respectively, and highest doses were reduced by 16.5%, 11.0%, 5.1%, 3.8%, and 1.5%, respectively. The optimization with purely biological OAR objectives was less effective for the eyes and optics nerves. EUDs for the left eye/right eye/left optic nerve/right optic nerve/chiasm were lower than that from DVO by 0.4%/2.7%/4.0%/2.8%/15.6% and highest doses were lower by 4.6%/1.4%/2.4%/6.4%/7.1% (but purely biological optimization was better overall for the OARs not targeted for EUD reduction). Conclusions: Incorporating biological optimization after dose-volume constrained optimization can further reduce biological metrics, while preserving the important dose reductions achieved by dose-volume constrained optimization. Thus, biological optimization may be accommodated within the framework of current IMRT planning clinical expectations.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dosimetric and Radiobiologic Comparison of 3D Conformal Versus Intensity Modulated Planning Techniques for Prostate Bed Radiotherapy

Adjuvant radiotherapy for locally advanced prostate cancer improves biochemical and clinical disease-free survival. While comparisons in intact prostate cancer show a benefit for intensity modulated radiation therapy (IMRT) over 3D conformal planning, this has not been studied for post-prostatectomy radiotherapy (RT). This study compares normal tissue and target dosimetry and radiobiological modeling of IMRT vs. 3D conformal planning in the postoperative setting. 3D conformal plans were designed for 15 patients who had been treated with IMRT planning for salvage post-prostatectomy RT. The same computed tomography (CT) and target/normal structure contours, as well as prescription dose, was used for both IMRT and 3D plans. Normal tissue complication probabilities (NTCPs) were calculated based on the dose given to the bladder and rectum by both plans. Dose-volume histogram and NTCP data were compared by paired t-test. Bladder and rectal sparing were improved with IMRT planning compared to 3D conformal planning. The volume of the bladder receiving at least 75% (V75) and 50% (V50) of the dose was significantly reduced by 28% and 17%, respectively (p = 0.002 and 0.037). Rectal dose was similarly reduced, V75 by 33% and V50 by 17% (p = 0.001 and 0.004). While there was no difference in the volume of rectum receiving at least 65 Gy (V65), IMRT planning significant reduced the volume receiving 40 Gy or more (V40, p = 0.009). Bladder V40 and V65 were not significantly different between planning modalities. Despite these dosimetric differences, there was no significant difference in the NTCP for either bladder or rectal injury. IMRT planning reduces the volume of bladder and rectum receiving high doses during post-prostatectomy RT. Because of relatively low doses given to the bladder and rectum, there was no statistically significant improvement in NTCP between the 3D conformal and IMRT plans.

61 RADIATION PROTECTION AND DOSIMETRY↗

Tracking brachytherapy sources using emission imaging with one flat panel detector

This work proposes to use the radiation from brachytherapy sources to track their dwell positions in three-dimensional (3D) space. The prototype device uses a single flat panel detector and a BB tray. The BBs are arranged in a defined pattern. The shadow of the BBs on the flat panel is analyzed to derive the 3D coordinates of the illumination source, i.e., the dwell position of the brachytherapy source. A kilovoltage x-ray source located 3.3 m away was used to align the center BB with the center pixel on the flat panel detector. For a test plan of 11 dwell positions, with an Ir-192 high dose rate unit, one projection was taken for each dwell point, and locations of the BB shadows were manually identified on the projection images. The 3D coordinates for the 11 dwell positions were reconstructed based on two BBs. The distances between dwell points were compared with the expected values. The average difference was 0.07 cm with a standard deviation of 0.15 cm. With automated BB shadow recognition in the future, this technique possesses the potential of tracking the 3D trajectory and the dwell times of a brachytherapy source in real time, enabling real time source position verification.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Clinical Evaluation of Positioning Verification Using Digital Tomosynthesis and Bony Anatomy and Soft Tissues for Prostate Image-Guided Radiotherapy

Purpose: To evaluate on-board digital tomosynthesis (DTS) for patient positioning vs. two-dimensional (2D) radiography and three-dimensional cone beam (CBCT). Methods and Materials: A total of 92 image sessions from 9 prostate cancer patients were analyzed. An on-board image set was registered to a corresponding reference image set. Four pairs of image sets were used: digitally reconstructed radiographs vs. on-board orthogonal paired radiographs for the 2D method, coronal-reference DTS vs. on-board coronal DTS for the coronal-DTS method, sagittal-reference DTS vs. on-board sagittal DTS for the sagittal-DTS method, and planning CT vs. CBCT for the CBCT method. The registration results were compared. Results: The systematic errors in all methods were <1 mm/1{sup o}. When registering the bony anatomy, the mean vector difference was 0.21 {+-} 0.11 cm between 2D and CBCT, 0.11 {+-} 0.08 cm between CBCT and coronal DTS, and 0.14 {+-} 0.07 cm between CBCT and sagittal DTS. The correlation between CBCT to DTS was stronger (coefficient = 0.92-0.95) than the correlation between 2D and CBCT or DTS (coefficient = 0.81-0.83). When registering the soft tissue, the mean vector difference was 0.18 {+-} 0.11 cm between CBCT and coronal DTS and 0.29 {+-} 0.17 cm between CBCT and sagittal DTS. The correlation coefficient of CBCT to sagittal DTS and to coronal DTS was 0.84 and 0.92, respectively. Conclusion: DTS could provide equivalent results to CBCT when the bony anatomy is used as landmarks for prostate image-guided radiotherapy. For soft tissue-based positioning verification, coronal DTS produced equivalent results to CBCT, but sagittal DTS alone was insufficient. DTS could allow for comparable soft tissue-based target localization with faster scanning time and a lower imaging dose compared with CBCT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Application of adaptive structures for the control of truss structures

Prospective NASA space efforts will require submicron dimensional-precision structures of 10-50 m and 20-30 year service lives, such as the 20 m-diameter Large Deployable Reflector; in most such designs, truss structures are selected due to their deployability and assemblability in space. An account is presently given of the critical role played by adaptive-structure concepts. A major aspect of these development efforts involves the use of the smallest feasible set of active members for the required functions; these can preload the structure, eliminate joint gaps, and adjust precision degrees-of-freedom.