Search NASA⌕ Search

Engineering topics

Daskalakis, A.

Publications and source records attributed to Daskalakis, A..

34 records · Page 2

Deployment of Gaussian Surrogate Model for Ad-Hoc Adjustments to Elastic Scattering Angular Distributions [Slides]

This presentation is on the deployment of gaussian surrogate model for ad-hoc adjustments to elastic scattering angular distributions. Discussed throughout the presentation is motivation for this lecture. Specifically, the gaussian surrogate models, validation of method with Pb-208, and the application on Be-9 are highlighted. The presentation concludes with a summary.

97 MATHEMATICS AND COMPUTING↗

Zirconium Scattering Sensitivity in Neutron Transport Calculations of Multiplying Systems [Slides]

This presentation touches on motivation and applications of Zirconium. Performance of evaluated libraries on double and quasi differential experiments is considered. Additionally, the performance of evaluated libraries in select ICSBEP benchmarks is considered. Provided is a detailed look in the performance of evaluated libraries in preliminary benchmark configurations for IER-516: Zirconium Test Assembly (ZTA). Conclusions and recommended experiments to satisfy Zirconium scattering nuclear data needs are presented.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Quasi-Differential Neutron Scattering Measurements of 181 Ta and Teflon from 1.5 to 20 MeV [Slides]

This presentation covers motivation for the Experiments Performed. Secondly, it touches on upgrades to the Experimental Apparatus for Measurements. Thirdly, it presents quasi-Differential Experimental Methodology a) Pulse Shape Discrimination b) Validation Measurement of Carbon. The presentation concludes with Preliminary Results and Future Studies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High Energy Quasi - Differential Neutron Emission Measurements of 181 Ta and 19 F [Slides]

This presentation begins with the motivation for performing 181 Ta and 19 F high energy quasi-differential and neutron emission measurements. It then provides a discussion of significant pulse digitization upgrade. The Quasi-Differential methodology and importance for validating nuclear data are provided. Preliminary results from 181 Ta and 19 F are displayed. The presentation concludes with a discussion and future studies.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Overview of Nuclear Data Measurement and Analysis at RPI [Slides]

This presentation discusses the experimental, simulation, and nuclear data methods that were validated for the RPI γ-Multiplicity Detector. When the neutron capture γ-cascade data is well-known, the γ-emission spectra can be accurately calculated using the modified simulation tools. The RPI γ-Multiplicity Detector system is now ready for analysis and recommendations for isotopes with deficiencies in γ-ray data. The presentation also discusses future work which includes developing a method for analyzing and adjusting nuclear data for 59 Co, 55 Mn and other measured isotopes including 181 Ta. Additionally, future work includes comparing experimental γ-emission spectra with MCNP-6.2/DICEBOX simulations for 238 U and 235 U. In summation, new capture and transmission measurements for 54 Fe will help improve resonance parameter evaluation. Neutron capture gamma cascade spectra and yields were measured in the resolved resonance region and compared to evaluations. In addition, the pulsed neutron die-away method was developed as a tool to provide data for validation of TSLs.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Update on NNL TSL Validation Efforts [Slides]

A new sub-thermal neutron transmission capability at RPI LINAC has been used to validate Be (metal). NNL transmission measurements validated NCSU Be and Be+Sd TSLs for ENDF/B-VIII.1 and showed improvements WRT ENDF/B-VII.1 and ENDF/B-VIII.0. Amplitude differences highlighted the importance of sample characterization. Additional measurement is in progress for CY2022. PNDA is being developed as an alternative to critical experiment validation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Update on NNL TSL Validation Efforts [Slides]

This presentation covers how a new sub-thermal neutron transmission capability at RPI LINAC is now in use to help validate TSL evaluations. Additionally, NNL has contributed multiple material evaluations to ENDF/B-VIII.1. Lastly, this presentation covers new methods to improve TSL physics and accuracy are being formulated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

CIELO Collaboration Summary Results: International Evaluations of Neutron Reactions on Uranium, Plutonium, Iron, Oxygen and Hydrogen

The CIELO collaboration has studied neutron cross sections on nuclides that significantly impact criticality in nuclear technologies - 235,238 U, 239 Pu, 56 Fe, 16 O and 1 H - with the aim of improving the accuracy of the data and resolving previous discrepancies in our understanding. This multi-laboratory pilot project, coordinated via the OECD/NEA Working Party on Evaluation Cooperation (WPEC) Subgroup 40 with support also from the IAEA, has motivated experimental and theoretical work and led to suites of new evaluated libraries that accurately reflect measured data and also perform well in integral simulations of criticality. This report summarizes our results on cross sections and preliminary work on covariances, and outlines plans for the next phase of this collaboration.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

IAEA CIELO Evaluation of Neutron-induced Reactions on 235 U and 238 U Targets

Evaluations of nuclear reaction data for the major uranium isotopes 238 U and 235 U were performed within the scope of the CIELO Project on the initiative of the OECD/NEA Data Bank under Working Party on Evaluation Co-operation (WPEC) Subgroup 40 coordinated by the IAEA Nuclear Data Section. Both the mean values and covariances are evaluated from 10 -5 eV up to 30 MeV. The resonance parameters of 238 U and 235 U were re-evaluated with the addition of newly available data to the existing experimental database. The evaluations in the fast neutron range are based on nuclear model calculations with the code EMPIRE–3.2 Malta above the resonance range up to 30 MeV. 235 U(n,f), 238 U(n,f), and 238 U(n,γ) cross sections and 235 U(n th ,f) prompt fission neutron spectrum (PFNS) were evaluated within the Neutron Standards project and are representative of the experimental state-of-the-art measurements. The Standards cross sections were matched in model calculations as closely as possible to guarantee a good predictive power for cross sections of competing neutron scattering channels. 235 U(n,γ) cross section includes fluctuations observed in recent experiments. 235 U(n,f) PFNS for incident neutron energies from 500 keV to 20 MeV were measured at Los Alamos Chi-Nu facility and re-evaluated using all available experimental data. While respecting the measured differential data, several compensating errors in previous evaluations were identified and removed so that the performance in integral benchmarks was restored or improved. Covariance matrices for 235 U and 238 U cross sections, angular distributions, spectra and neutron multiplicities were evaluated using the GANDR system that combines experimental data with model uncertainties. Unrecognized systematic uncertainties were considered in the uncertainty quantification for fission and capture cross sections above the thermal range, and for neutron multiplicities. Evaluated files were extensively benchmarked to ensure good performance in reactor calculations and fusion-related systems. New comprehensive evaluations show excellent agreement with available differential data and integral performance better than current evaluated data libraries, and represent a step forward in a quest for better nuclear data for applications.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of prompt fission neutron spectrum for spontaneous fission of Cf 252 using γ multiplicity tagging

The prompt fission neutron spectrum from spontaneous fission of 252 Cf is an integral part of several aspects of nuclear data. Not only is the spectrum itself of interest, but neutron detectors often use the spectrum for calibration, and other prompt fission neutron spectra are measured as a ratio to 252 Cf. Therefore, reducing the uncertainties in this spectrum will allow for more accurate nuclear data to be available across a wide range of fields. The prompt fission neutron spectrum for the spontaneous fission of 252 Cf was measured at Rensselaer Polytechnic Institute using the multiple γ tagging method with a 18.4-ng fission sample. An EJ-301 liquid scintillator fast neutron detector was used to measure the high energy portion of the spectrum, 0.5–7 MeV, and a thin EJ-204 plastic scintillator was used to measure the low energy portion of the spectrum, from 50 keV to 2 MeV. These spectra both show good agreement with the current evaluation of 252 Cf and have low associated uncertainties providing a new high precision measurement that helps reduce the uncertainties in the prompt fission neutron spectrum for the spontaneous fission of 252 Cf.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A method to measure prompt fission neutron spectrum using gamma multiplicity tagging

In order to improve on current prompt fission neutron spectrum measurements, a gamma multiplicity tagging method was developed at the Rensselaer Polytechnic Institute Gearttner Linear Accelerator Center. This method involves using a coincidence requirement on an array of BaF 2 gamma detectors to determine the timing of a fission event. This allows for much larger fission samples to be used due to the higher penetrability of gammas compared to fission fragments. Additionally, since the method relies on gammas as opposed to fission fragments, the effects of the low level discriminator, used in fission chambers to eliminate alpha events, are not seen. A 252 Cf fission chamber was constructed in order to determine the viability of this method as well as the efficiency when compared to a fission chamber. The implemented multiple gamma tagging method was found to accurately reproduce the prompt fission neutron spectrum for the spontaneous fission of 252 Cf and to detect 30% of fission events.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Capture Cross Section Measurements in {sup nat}Fe and {sup 181}Ta from 1 to 2000 keV Using a New C6D6 Detector Array

A new array of four C6D6 detectors has been developed at the Rensselaer Polytechnic Institute Gaerttner LINAC center for the purposes of measuring neutron capture cross sections in the keV resonance region with low sensitivity to scattered neutrons. The new detection apparatus incorporates low-mass, low cross-section materials to reduce neutron sensitivity, and uses digital data acquisition equipment to enable saving of the full waveform output of each detector module for offline analysis. Capture yields are determined by applying the total energy method and pulse height weighting technique during the analysis of the saved data. Measurements have been performed on samples of iron and tantalum using the new system, with results consistent with existing data libraries. (authors)

42 ENGINEERING↗

Isotopic molybdenum total neutron cross section in the unresolved resonance region

Accurate isotopic molybdenum nuclear data are important because molybdenum can exist in nuclear reactor components including fuel, cladding, or as a high yield fission product. High-resolution time-of-flight neutron transmission measurements on highly enriched isotopic metallic samples of 95 Mo, 96 Mo, 98 Mo, and 100 Mo were performed in the resonance energy range from 1 to 620 keV. The measurements were taken with the newly developed modular 6 Li-glass transmission detector positioned at the 100-m experimental flight station. For the unresolved energy region (URR), new comprehensive methods of analysis were developed and validated in order to obtain accurate neutron total cross-section data from the measurement by correcting for background and transmission enhancement effects. Average parameters and fits to the total cross section for 95 Mo were obtained using the Hauser-Feshbach statistical model code FITACS, which is currently incorporated into the SAMMY code. Moreover, fits to the experimental data deviate from the current evaluated nuclear data file/B-VII.1 isotopic Mo evaluations by several percent in the URR.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Measurement of Fission Neutron Spectrum and Multiplicity using a Gamma Tag Double Time-of-flight Setup

Recent efforts have been made to improve the prompt fission neutron spectrum and nu-bar measurements for Uranium and Plutonium isotopes particularly in the keV region. A system has been designed at Rensselaer Polytechnic Institute (RPI) utilizing an array of EJ-301 liquid scintillators as well as lithium glass and plastic scintillators to experimentally determine these values. An array of BaF2 detectors was recently obtained from Oak Ridge National Laboratory to be used in conjunction with the neutron detectors. The system uses a novel gamma tagging method for fission which can offer an improvement over conventional fission chambers due to increased sample mass. A coincidence requirement on the gamma detectors from prompt fission gammas is used as the fission tag for the system as opposed to fission fragments in a conventional fission chamber. The system utilizes pulse digitization using Acqiris 8 bit digitizer boards which allow for gamma/neutron pulse height discrimination on the liquid scintillators during post processing. Additionally, a 252Cf fission chamber was designed and constructed at RPI which allowed for optimization and testing of the system without the need for an external neutron source. The characteristics of the gamma tagging method such as false detection rate and detection efficiency were determined using this fission chamber and verified using MCNP Polimi modeling. Prompt fission neutron spectrum data has been taken using the fission chamber focusing on the minimum detectable neutron energy for each of the various detectors. Plastic scintillators were found to offer a significant improvement over traditional liquid scintillators allowing energy measurements down to 50 keV. Background was also characterized for all detectors and will be discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗