Search NASA⌕ Search

Engineering topics

Dauffy, L

Publications and source records attributed to Dauffy, L.

Simulation of the Post-Shot Radiation Environment in the National Ignition Facility

The National Ignition Facility at Lawrence Livermore National Laboratory is the world’s biggest and most energetic laser system for inertial confinement fusion. The NIF is designed to perform shots with varying fusion yield (up to 20 MJ or 7.1 × 10 18 neutrons per shot). A great number of diagnostic instruments are present inside the target chamber (TC) and target bay (TB) during shots. The gamma dose rates due to neutron activation are estimated at various decay times following the high-yield (20-MJ) shots. Several components, like the snout assemblies of the diagnostic instrument manipulators and target positioners are inserted inside the TC, close to the target during the shot. These components represent major sources of gamma decay after retraction outside the TC. Five days after a 20-MJ shot, dose rates near the highly activated (retracted) parts are on the order of 1 mSv/h and dose rates within the TB outside the TC but at distance from the retracted components drop to about 50 to 70 μSv/h. The dose is dominated by decay of 24 Na (T 1/2 = 14.95 h) and waiting for two additional days drops the dose rates significantly. Seven days following a 20-MJ shot, dose rates in the immediate vicinity of the retracted components drop to <0.2 mSv/h and the general ambient dose rates within the TB (away from retracted components) near the TC drop to <10 μSv/h. Dose rates at much larger distances from the TC (near TB wall) are an order of magnitude lower. Detailed radiation transport simulations are performed to create detailed dose rate maps for all floors inside the TB. The maps are used to measure worker stay-out times following shots before entry is permitted into the TB.

61 RADIATION PROTECTION AND DOSIMETRY↗

POST-SHOT RADIATION ENVIRONMENT FOLLOWING LOW-YIELD SHOTS INSIDE THE NATIONAL IGNITION FACILITY

A detailed model of the Target Bay (TB) at the National Ignition Facility (NIF) has been developed to estimate the post-shot radiation environment inside the facility. The model includes large number of structures and diagnostic instruments present inside the TB. These structures and instruments are activated by the few nanosecond pulse of neutrons generated during a shot and the resultant gamma dose rates are estimated at various decay times following the shot. The results presented in this paper are based on a low-yield D-T shot of 10{sup 16} neutrons. General environment dose rates drop to below 3 mrem/h within three hours following a shot with higher dose rates observed at contact with some of the components. Dose rate maps of the different TB levels were generated to aid in estimating worker stay-out times following a shot before entry is permitted into the TB.

61 RADIATION PROTECTION AND DOSIMETRY↗

PLANNING TOOLS FOR ESTIMATING RADIATION EXPOSURE AT THE NATIONAL IGNITION FACILITY

A set of computational tools was developed to help estimate and minimize potential radiation exposure to workers from material activation in the National Ignition Facility (NIF). AAMI (Automated ALARA-MCNP Interface) provides an efficient, automated mechanism to perform the series of calculations required to create dose rate maps for the entire facility with minimal manual user input. NEET (NIF Exposure Estimation Tool) is a web application that combines the information computed by AAMI with a given shot schedule to compute and display the dose rate maps as a function of time. AAMI and NEET are currently used as work planning tools to determine stay-out times for workers following a given shot or set of shots, and to help in estimating integrated doses associated with performing various maintenance activities inside the target bay. Dose rate maps of the target bay were generated following a low-yield 10{sup 16} D-T shot and will be presented in this paper.

42 ENGINEERING↗

Diagnosing inertial confinement fusion gamma ray physics (invited)

The gamma reaction history (GRH) diagnostic is a multichannel, time-resolved, energy-thresholded {gamma}-ray spectrometer that provides a high-bandwidth, direct-measurement of fusion reaction history in inertial confinement fusion implosion experiments. 16.75 MeV deuterium+tritium (DT) fusion {gamma}-rays, with a branching ratio of the order of 10{sup -5}{gamma}/(14 MeV n), are detected to determine fundamental burn parameters, such as nuclear bang time and burn width, critical to achieving ignition at the National Ignition Facility. During the tritium/hydrogen/deuterium ignition tuning campaign, an additional {gamma}-ray line at 19.8 MeV, produced by hydrogen+tritium fusion with a branching ratio of unity, will increase the available {gamma}-ray signal and may allow measurement of reacting fuel composition or ion temperature. Ablator areal density measurements with the GRH are also made possible by detection of 4.43 MeV {gamma}-rays produced by inelastic scatter of DT fusion neutrons on {sup 12}C nuclei in the ablating plastic capsule material.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Diagnosing ICF gamma-ray physics

Gamma rays produced in an ICF environment open up a host of physics opportunities we are just beginning to explore. A branch of the DT fusion reaction, with a branching ratio on the order of 2e-5 {gamma}/n, produces 16.7 MeV {gamma}-rays. These {gamma}-rays provide a direct measure of fusion reaction rate (unlike x-rays) without being compromised by Doppler spreading (unlike neutrons). Reaction-rate history measurements, such as nuclear bang time and burn width, are fundamental quantities that will be used to optimize ignition on the National Ignition Facility (NIF). Gas Cherenkov Detectors (GCD) that convert fusion {gamma}-rays to UV/visible Cherenkov photons for collection by fast optical recording systems established their usefulness in illuminating ICF physics in several experimental campaigns at OMEGA. Demonstrated absolute timing calibrations allow bang time measurements with accuracy better than 30 ps. System impulse response better than 95 ps fwhm have been made possible by the combination of low temporal dispersion GCDs, ultra-fast microchannel-plate photomultiplier tubes (PMT), and high-bandwidth Mach Zehnder fiber optic data links and digitizers, resulting in burn width measurement accuracy better than 10ps. Inherent variable energy-thresholding capability allows use of GCDs as {gamma}-ray spectrometers to explore other interesting nuclear processes. Recent measurements of the 4.44 MeV {sup 12}C(n,n{prime}) {gamma}-rays produced as 14.1 MeV DT fusion neutrons pass through plastic capsules is paving the way for a new CH ablator areal density measurement. Insertion of various neutron target materials near target chamber center (TCC) producing secondary, neutron-induced {gamma}y-rays are being used to study other nuclear interactions and as in-situ sources to calibrate detector response and DT branching ratio. NIF Gamma Reaction History (GRH) diagnostics, based on the GCD concept, are now being developed based on optimization of sensitivity, bandwidth, dynamic range, cost, and NIF-specific logistics, requirements and extreme radiation environment. Implementation will occur in two phases: (1) four PMT-based channels mounted to the outside of the target chamber at {approx}6m from TCC (GRH-6m) for the 3e13-3e16 DT neutron yield range expected during the early ignition-tuning campaigns; and (2) several channels located just inside the target bay shield wall at 15 m from TCC (GRH-15m) with optical paths leading through the cement shield wall to well-shielded streak cameras and PMTs for the 1e16-1e20 yield range expected during the DT ignition campaign. Multiple channels at each phase will allow for increased redundancy, reliability, accuracy and flexibility. This suite of diagnostics will make possible exploration of interesting {gamma}-ray physics well beyond the ignition campaign.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Assessment and Mitigation of Radiation, EMP, Debris & Shrapnel Impacts at Megajoule-Class Laser Facilities

The generation of neutron/gamma radiation, electromagnetic pulses (EMP), debris and shrapnel at mega-Joule class laser facilities (NIF and LMJ) impacts experiments conducted at these facilities. The complex 3D numerical codes used to assess these impacts range from an established code that required minor modifications (MCNP - calculates neutron and gamma radiation levels in complex geometries), through a code that required significant modifications to treat new phenomena (EMSolve - calculates EMP from electrons escaping from laser targets), to a new code, ALE-AMR, that is being developed through a joint collaboration between LLNL, CEA, and UC (UCSD, UCLA, and LBL) for debris and shrapnel modelling.

36 MATERIALS SCIENCE↗

Simulation of Radiation Backgrounds associated with the HEXRI Diagnostics at the National Ignition Facility

Experiments resulting in a significant neutron yield are scheduled to start in 2010 at the National Ignition Facility (NIF). A wide range of diagnostics will be used to measure several parameters of implosion such as the core and fuel shape, temperatures and densities, and neutron yield. Accurate evaluations of the neutron and gamma backgrounds are important for several diagnostics, such as the High Energy X-ray Imager (HEXRI). Several Monte-Carlo simulations were performed to identify the expected signal to background ratios at several potential locations for the HEXRI diagnostics. Gamma backgrounds were significantly reduced by using tungsten collimators. The collimators resulted in the reduction of the gamma background at the HEXRI scintillators by more than an order of magnitude during the first 40 ns following a THD shot.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Neutron Activation of NIF Final Optics Assemblies

Analyses were performed to characterize the radiation field in the vicinity of the Final Optics Assemblies (FOAs) at the National Ignition Facility (NIF) due to neutron activation following Deuterium-Deuterium (DD), Tritium-Hydrogen-Deuterium (THD), and Deuterium-Tritium (DT) shots associated with different phases of the NIF operations. The activation of the structural components of the FOAs produces one of the larger sources of gamma radiation and is a key factor in determining the stay out time between shots to ensure worker protection. This study provides estimates of effective dose rates in the vicinity of a single FOA and concludes that the DD and THD targets produce acceptable dose rates within 10 minutes following a shot while about 6-days of stay out time is suggested following DT shots. Studies are ongoing to determine the combined effects of multiple FOAs and other components present in the Target Bay on stay-out time and worker dose.

61 RADIATION PROTECTION AND DOSIMETRY↗