Thermal Vacuum and Vibration Testing of the Differential Thermal Expansion Thermal Switch

The Extended Stroke, Reverse Operation, Differential Thermal Expansion (DTE) Thermal Switch (TS) for Extreme Variable Environments uses materials with both positive and negative coefficients of thermal expansion (CTE) arranged in concentric cylinders so that the TS operates passively, opening a gap between interfaces to create a low thermal contact when cold, and closing the gap between interfaces to create a high thermal contact when hot. This paper details the testing of the TS at Marshall Space Flight Center (MSFC) including the vibration (vibe) test, pre-vibe thermal vacuum (t-vac) cycle test, post-vibe t-vac cycle test, and long duration t-vac cycle test. The data collected from the pre- and post-vibe tests are compared to show the impact of the vibe test on performance. The data collected from the long duration test is used to calculate the total thermal contact conductance through the TS interfaces for both ‘on’ (TS closed, during hot plateau) and ‘off’ (TS open, during cold plateau) configurations, and the turndown ratio is also calculated. Challenges experienced throughout testing are also discussed.

Thermal control technology↗

Thermal Vacuum and Vibration Testing of the Differential Thermal Expansion Thermal Switch

The Extended Stroke, Reverse Operation, Differential Thermal Expansion (DTE) Thermal Switch (TS) for Extreme Variable Environments uses materials with both positive and negative coefficients of thermal expansion (CTE) arranged in concentric cylinders so that the TS operates passively, opening a gap between interfaces to create a low thermal contact when cold, and closing the gap between interfaces to create a high thermal contact when hot. This paper details the testing of the TS at Marshall Space Flight Center (MSFC) including the vibration (vibe) test, pre-vibe thermal vacuum (t-vac) cycle test, post-vibe t-vac cycle test, and long duration t-vac cycle test. The data collected from the pre- and post-vibe tests are compared to show the impact of the vibe test on performance. The data collected from the long duration test is used to calculate the total thermal contact conductance through the TS interfaces for both ‘on’ (TS closed, during hot plateau) and ‘off’ (TS open, during cold plateau) configurations, and the turndown ratio is also calculated. Challenges experienced throughout testing are also discussed.

Thermal control technology↗

Simulated Lunar Gravity Testing of VIPER Loop Heat Pipe

NASA’s Volatiles Investigating Polar Exploration Rover (VIPER) mission consists of a rover designed to explore the lunar south pole. One of the main challenges faced by the rover during the lunar polar exploration is the adverse thermal environment. Temperatures can fluctuate more than a 100°C between day and night; potentially dropping to −246°C in permanent shadow regions. To maintain the rover components within temperature limits, VIPER’s Thermal Management System (TMS) relies heavily on Loop Heat Pipes (LHPs). To assist the design of the thermal management system, an Engineering Design Unit (EDU) LHP has been tested in several opportunities under thermal vacuum (TVAC) environment. Of particular interest was the LHP performance in lunar gravity. To that end, the EDU LHP was tested at the nominal orientation within the rover assembly, vertical, and inclined such that the gravitational component acting on the LHP evaporator and condenser was 1/6g (lunar gravity is 1/6 of Earth gravity) when compared to the vertical configuration. This paper will examine the LHP conductance as one the key parameters to assess the effect of the gravity on the LHP performance.

Loop Heat Pipe↗