Engineering topics
Davidson, David F.
Publications and source records attributed to Davidson, David F..
Shock tube/laser absorption measurement of the rate constant of the reaction: H 2 O 2 + CO 2 2OH + CO 2
We address the role of the linear mixing rule in the kinetics of the H 2 O 2 decomposition system by reporting the rate constant for H 2 O 2 + M = 2OH + M (M = Ar and CO 2 ) in the temperature range of 1087-1234 K at low pressures in a mixture of 20% CO 2 in Argon. The reaction rate constant was inferred from H 2 O concentrations monitored by using a laser-absorption spectroscopy-based water diagnostic. To the best of our knowledge, this is the first measurement of the rate constant of this reaction in a mixture to be reported in literature. A significant discrepancy was found between the rate constants derived using the traditional linear mixing rule and the reduced pressure linear mixing rule. Furthermore, this discrepancy can have serious implications on the predictive accuracy of these kinetic models, especially under conditions relevant to the operation of supercritical CO 2 (sCO 2 ) power cycles that rely on oxy-fuel combustion in a working fluid comprised almost entirely of CO 2 .
Rapid tuning CW laser technique for measurements of gas velocity, temperature, pressure, density, and mass flux using NO
An intracavity-doubled rapid-tuning CW ring dye laser was used to acquire fully resolved absorption profiles of NO line pairs in the A-X band at 225 nm at a rate of 4 kHz. These profiles were utilized for simultaneous measurements of flow parameters in the high-speed 1D flows generated in a shock tube. Velocity was determined from the Doppler shift, measured using a pair of profiles simultaneously acquired at different angles with respect to the flow direction. Temperature was determined from the intensity ratio of the adjacent lines. Pressure and density were found both from the collisional broadening and the fractional absorption. From this information the mass flux was determined. The results compare well to 1D shock calculations.
Continuous wave laser absorption techniques for gasdynamic measurements in supersonic flows
Line-of-sight measurements of velocity, temperature, pressure, density, and mass flux were performed in a transient shock tube flow using three laser absorption schemes. All methods employed an intracavity-doubled ring dye laser tuned to an OH transition at 306 nm. In the first scheme, the gas was labeled by 193.3-nm excimer photolysis of H2O, and the passage of the generated OH was detected downstream. In the second method, the laser was tuned at a rate of 3 kHz over the R1(7) and R1(11) line pair, and absorption was simultaneously monitored at 90 and 60 deg with respect to the flow. Velocity was determined from the Doppler shift of the profiles and the temperature from the intensity ratio of the lines. Pressure was determined from both the magnitude of absorption and the collisional broadening. In the third method, the laser wavelength was fixed at a single frequency, and a continuous measurement of velocity and pressure was obtained using the signals from the two beam paths. All methods gave results which compare favorably to calculated values.