Optical design of Lyman/FUSE
The optical system for the proposed Lyman/Far UV Spectroscopic Explorer (FUSE) orbiting observatory is described and illustrated with drawings and graphs of predicted performance. The system comprises (1) an FUV channel based on a 1.84-m-diameter Rowland circle spectrograph with five high-density modified ellipsiodal near-normal-incidence gratings and an array of four MAMA detectors; (2) an EUV channel with ellipsoidal mirror, planar varied-line-space grating, microchannel-plate array, and wedge-and-strip anode detector; (3) a 70-cm Wolter II glancing-incidence telescope; and (4) a CCD-detector fine-error sensor to provide accurate pointing (within 200 marcsec rms). The resolving powers of the spectrographs are 30,000 in the FUV and 300-600 (wavelength-dependent) in the EUV.