Search NASA⌕ Search

Engineering topics

Davila, Pamela

Publications and source records attributed to Davila, Pamela.

An Overview of Integration and Test of the James Webb Space Telescope Integrated Science Instrument Module

The James Webb Space Telescope (JWST) is a 6.6m diameter, segmented, deployable telescope for cryogenic IR space astronomy (approx.40K). The JWST Observatory architecture includes the Optical Telescope Element (OTE) and the Integrated Science Instrument Module (ISIM) element that contains four science instruments (SI) including a Guider. The SIs and Guider are mounted to a composite metering structure with outer dimensions of 2.1x2.2x1.9m. The SI and Guider units are integrated to the ISIM structure and optically tested at NASA/Goddard Space Flight Center as an instrument suite using a high-fidelity, cryogenic JWST telescope simulator that features a 1.5m diameter powered mirror. The SIs are integrated and aligned to the structure under ambient, clean room conditions. SI performance, including focus, pupil shear and wavefront error, is evaluated at the operating temperature. We present an overview of the ISIM integration within the context of Observatory-level construction. We describe the integration and verification plan for the ISIM element, including an overview of our incremental verification approach, ambient mechanical integration and test plans and optical alignment and cryogenic test plans. We describe key ground support equipment and facilities.

Drury, Michael↗

Cryogenic System for Interferometry of High-precision Optics at 20 K: Design and Performance

This report describes the facility and experimental methods at the Goddard Space Flight Center Optics Branch for the measurement of the surface figure of cryogenically-cooled spherical mirrors using standard phase-shifting interferometry, with a standard uncertainty below 2nm rms. Two developmental silicon carbide mirrors were tested: both were spheres with radius of curvature of 600 mm, and clear apertures of 150 mm. The mirrors were cooled within a cryostat, and the surface figure error measured through a fused-silica window. The GSFC team developed methods to measure the in-situ SFE at 20 K with a combined standard uncertainty below 2 nm rms and the change in SFE with temperature (the cryochange) with a combined standard uncertainty of 0.25 -- 0.75 nm rms. This paper will present the measurement facility, methods, and uncertainty analysis.

Blake,Peter↗

Minimizing Uncertainty in Cryogenic Surface Figure Measurement

A new facility at the Goddard Space Flight Center is designed to measure with unusual accuracy the surface figure of mirrors at cryogenic temperatures down to 12 K. The facility is currently configured for spherical mirrors with a radius of curvature (ROC) of 600 mm, and apertures of about 150 mm or less. The goals of the current experiment were to 1) Obtain the best possible estimate of test mirror surface figure, S(x,y) at 87 K and 20 K; 2) Obtain the best estimate of the cryo-change, Delta (x,y): the change in surface figure between room temperature and the two cryo-temperatures; and 3) Determine the uncertainty of these measurements, using the definitions and guidelines of the ISO Guide to the Expression of Uncertainty in Measurement. A silicon mirror was tested, and the cry-change from room temperature to 20K was found to be 3.7 nm rms, with a standard uncertainty of 0.23 nm in the rms statistic. Both the cryo-change figure and the uncertainty are among the lowest such figures yet published. This report describes the facilities, experimental methods, and uncertainty analysis of the measurements.

Blake, Peter↗

Surface Figure Measurement of Silicon Carbide Mirrors at Cryogenic Temperatures

The surface figure of a developmental silicon carbide mirror, cooled to 87 K and then 20 K within a cryostat, was measured with unusually high precision at the Goddard Space Flight Center (GSFC). The concave spherical mirror, with a radius of 600 mm and a clear aperture of 150 mm, was fabricated of sintered silicon carbide. The mirror was mounted to an interface plate representative of an optical bench, made of the material Cesic@, a composite of silicon, carbon, and silicon carbide. The change in optical surface figure as the mirror and interface plate cooled from room temperature to 20 K was 3.7 nm rms, with a standard uncertainty of 0.23 nm in the rms statistic. Both the cryo-change figure and the uncertainty are among the lowest such figures yet published. This report describes the facilities, experimental methods, and uncertainty analysis of the measurements.

Blake, Peter↗

Surface Figure Measurement at 20K: Silicon Carbide and Cesic Mirrors

This report presents the facility, methods, and results of testing cryogenically-cooled spherical mirrors, using standard phase-shifting interferometry, at the Goddard Space Flight Center (GSFC). Two mirrors were supplied to GSFC by the European Space Technology Center, so that GSFC could render a second, independent cryo-measurement of their surface figures at 20K. These mirrors, produced by Galileo Avionica and its partners, demonstrate the technology of silicon carbide and SiC-composite lightweighted mirrors, designed for high accuracy (10 nm rms surface figure error) at both room temperature and 20K. The two mirrors provided for testing at GSFC include one made of sintered silicon carbide (mirror blank by Bettini), and a second made of the C/Si/SiC composite known as Cesic (supplied by ECM). Both mirrors are f/2 spheres with 150 mm clear aperture, and with integral mounts. At GSFC, the mirrors will be measured first at at room temperature, making use of standard techniques, with a predicted uncertainty of 2 nm. Then each mirror will be tested in the cryostat, down to 20K: first freely supported and, second, mounted to a Cesic plate that models a Cesic optical bench. The uncertainty of the resultant surface figure error is predicted to be about 5 nm rms. Details of the uncertainty budget are discussed in a related poster. GSFC's techniques and results can be usefully compared to the measurements performed on the same two mirrors by and for Galileo Avionica, who used a somewhat different test configuration and alignment approach.

Blake, Peter↗

High-Accuracy Surface Figure Measurement of Silicon Mirrors at 80 K

This report describes the equipment, experimental methods, and first results at a new facility for interferometric measurement of cryogenically-cooled spherical mirrors at the Goddard Space Flight Center Optics Branch. The procedure, using standard phase-shifting interferometry, has an standard combined uncertainty of 3.6 nm rms in its representation of the two-dimensional surface figure error at 80, and an uncertainty of plus or minus 1 nm in the rms statistic itself. The first mirror tested was a concave spherical silicon foam-core mirror, with a clear aperture of 120 mm. The optic surface was measured at room temperature using standard absolute techniques; and then the change in surface figure error from room temperature to 80 K was measured. The mirror was cooled within a cryostat. and its surface figure error measured through a fused-silica window. The facility and techniques will be used to measure the surface figure error at 20K of prototype lightweight silicon carbide and Cesic mirrors developed by Galileo Avionica (Italy) for the European Space Agency (ESA).

Blake, Peter↗