Search NASA⌕ Search

Engineering topics

Davisson, M. Lee

Publications and source records attributed to Davisson, M. Lee.

Hydrogen and oxygen stable isotope composition of water in metaschoepite mineralization on U 3 O 8

When exposed to humidity in an oxidizing atmosphere hydrated uranium oxide grows as a secondary mineral on aged U 3 O 8 and may incorporate the oxygen stable isotope signature of the water vapor into the secondary uranium oxide, as well as hydrogen and oxygen stable isotopes into any mineral hydration water. Because geospatial variation in δ 2 H and δ 18 O values of atmospheric humidity and precipitation is well understood, the H and O stable isotope composition of mineral hydration waters can give information on the environment of mineral formation. We exposed powdered U 3 O 8 to humidity with known H and O stable isotope composition at constant 30%, 61% and 91% relative humidity. We sampled and analyzed the U 3 O 8 powders along with any secondary hydrated minerals that had formed on the particle surfaces at various intervals from 1 to 10 days throughout the 180-day humidity exposures. We present stable H and O isotope results of mineral hydration waters in uranium oxide materials analyzed by thermogravimetry-enabled isotope ratio infrared spectroscopy (TGA-IRIS), which uses precise heating by thermogravimetric analyzer to liberate water vapor for subsequent online isotope analysis via a laser-based isotope ratio infrared spectroscopy instrument (Picarro L-2130i). Scanning electron microscopy (SEM), transmission electron microscopy (TEM), and x-ray diffraction (XRD) analysis of humidity-exposed U 3 O 8 heated to 350 °C indicates that the U 3 O 8 had a measurable metaschoepite ((UO 3 )•2H 2 O) phase along with α-U 3 O 8 . After heating to 350 °C, the metaschoepite is eliminated but the α-U 3 O 8 is retained, meaning that the heating successfully extracted the water in the metaschoepite but did not disturb the crystalline structure of the U 3 O 8 . Analysis of the bulk oxygen isotope composition by fluorination of these samples before and after heating, indicates that the oxygen isotope value of the U 3 O 8 is also not affected by heating to 350 °C. Precision for δ 2 H and δ 18 O values of metaschoepite mineral hydration water stable isotope values yielded by the TGA-IRIS method on metaschoepite are 5.86‰ for δ 2 H, and 0.34‰ for δ 18 O. Hydrogen in the various water reservoirs is highly exchangeable and thus the δ 2 H values of these waters is not easily interpreted. However, oxygen in the separate water reservoirs is much less exchangeable, and thus δ 18 O values of the metaschoepite mineral hydration water is likely to reflect that of the water vapor the sample was exposed to. Once metaschoepite is formed on the surface of U 3 O 8 particles, the oxygen isotope signature of the mineral hydration water in metaschoepite does not respond to changes in exposure vapor isotopic composition, and thus appears to be fairly durable in this regard. Furthermore, these results suggest that it may be possible to discern information about the provenance and history of an oxidized U 3 O 8 sample from oxygen stable isotope measurements of metaschoepite mineral hydration water.

07 ISOTOPE AND RADIATION SOURCES↗

Water vapor exposure chamber for constant humidity and hydrogen and oxygen stable isotope composition

Rationale: Water vapor exposure experiments have applications for studying water physisorption and chemisorption hydration and hydroxylation reactions on a wide variety of material surfaces. The stable isotopes of hydrogen and oxygen in the water molecule are useful tracers of water exchange mechanisms and/or rates in such vapor exposure experiments. Methods: We designed and built a humidity chamber system that uses membrane-mediated liquid–vapor exchange of water followed by mixing with dry air to control the relative humidity of air and its δ 2 H and δ 18 O isotopic composition. We tested the stability and precision of the humidity and its isotopic composition on hourly to 90-day timescales. Results: The humidity chamber design reported here is capable of providing relative humidity control to within ±1%, and consistent δ 2 H and δ 18 O values of the water vapor that are similar to our cavity ringdown spectroscopy (CRDS) measurement precision (δ2H vap ± 0.7‰ and δ18O vap ± 0.24‰). We quantify the isotopic enrichment effects of Rayleigh distillation in the system and provide information on water reservoir sizes large enough to buffer isotopic enrichment effects to within measurement precision. Conclusions: The humidity chamber design reported here provides a means to create constant δ2H and δ18O values over the course of an exposure experiment. The design has applications to a wide range of studies of water sorption on material surfaces from foods and pharmaceuticals to geological materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Hydrogen and oxygen stable isotope dynamics of hyper-saline and salt-saturated aqueous solutions

An attractive tracer of water-surface interactions in humidity exposure experiments are the stable hydrogen and oxygen isotopes in water vapor, though the conventional method of using salt saturated aqueous solutions to control humidity is likely to exert strong effects on the H and O stable isotope composition of the vapor. The magnitude of these effects are virtually unknown for hyper-saline solutions near salt saturation and beyond. Here we explore the hydrogen and oxygen stable isotope effects of salt-water mixtures from dilute to the salt saturation point and beyond for BaCl 2 , CaCl 2 , KCl, K 2 SO 4 , MgCl 2 , NaBr, NaCl, and NaI salts, of which the O isotope results on BaCl 2 , K 2 SO 4 , and NaBr are the first to be reported, and the first for H with BaCl2. We find that vapor humidity levels, and hydrogen and oxygen isotope effects in the vapor generated from dilute solutions to salt-saturated mixtures increase in magnitude by predictable linear trends. In the case of hydrogen isotope salt effects, the cation identity matters, as the effect becomes stronger with decreasing size and increasing charge (increasing ionic potential) in the sequence of: K < Na < Ba < Ca < Mg. For oxygen, the cation effect becomes stronger with increasing ionic potential, in the order of Na < Ba < K < Ca < Mg (irrespective of sign). Hydrogen and oxygen isotope effects in vapor from salt concentrations greater than the salt saturation point do not behave as systematically, with some of the salts displaying no increase in isotope effects beyond saturation, while others show an increase in isotope effects beyond salt saturation, especially in the case of hydrogen. We make specific recommendations on the salts that exert hydrogen and oxygen isotope effects with the least magnitude and most predictability for humidity levels from 26% to 92%. The use of salt solutions to create vapor at less than 100% and with specific δ 2 H and δ 18 O values that differ from that defined by the global meteoric water relationship also seems possible. Hyper-saline surface waters can exist at and above saturation, and thus these isotope effects may be present in them, as well as in minerals that form from these waters.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Relative impact of H 2 O and O 2 in the oxidation of UO 2 powders from 50 to 300 °C

Here, we studied the reaction of water and molecular oxygen with stoichiometric uranium dioxide (i.e. UO 2 ) powder at elevated temperature by high-resolution x-ray photoelectron spectroscopy (XPS), infrared (IR) spectroscopy, powder x-ray diffraction (XRD), and scanning electron microscopy (SEM). We observed and quatified oxidation resulting from the dissociative chemisorption of the adsorbing molecules and subsequent incorporation into the oxide lattice. Molecular oxygen was found to be a stronger oxidation agent than water at elevated temperatures but not at ambient.

36 MATERIALS SCIENCE↗

An XPS study on the impact of relative humidity on the aging of UO 2 powders

High resolution x-ray photoemission spectroscopy (XPS) was used to characterize the chemical speciation of high purity uranium dioxide (UO 2 ) powder samples following aging for periods of up to one year under controlled conditions with relative humidity ranging from 34% to 98%. A systematic shift to higher uranium oxidation states, and thus an increase in the mean uranium valence, was found to directly correlate with the dose of water received (i.e. the product of exposure time and relative humidity). Exposure duration was found to have a greater impact on sample aging than relative humidity. Lastly, the sample aged at 98% relative humidity was found to have unique structural differences for exposure time beyond 180 days when observed by scanning electron microscopy (SEM).

36 MATERIALS SCIENCE↗

XPS Investigation on Changes in UO 2 Speciation following Exposure to Humidity

High purity UO 2 powder samples were subjected to accelerated aging under controlled conditions with relative humidity ranging from 34% to 98%. Characterization of the chemical speciation of the products was accomplished using X-ray photoelectron spectroscopy (XPS). A shift to higher uranium oxidation states was found to be directly correlated to increased relative humidity exposure. In addition, the relative abundance of O 2- , OH - , and H 2 O was found to vary with exposure time. Therefore, it is expected that uranium oxide materials exposed to high relative humidity conditions during processing and storage would display a similar increase in average uranium valence.

36 MATERIALS SCIENCE↗

Correlated SEM, FIB-SEM, TEM, and NanoSIMS Imaging of Microbes from the Hindgut of a Lower Termite: Methods for In Situ Functional and Ecological Studies of Uncultivable Microbes

The hindguts of lower termites harbor highly diverse, endemic communities of symbiotic protists, bacteria, and archaea essential to the termite's ability to digest wood. Despite over a century of experimental studies, ecological roles of many of these microbes are unknown, partly because almost none can be cultivated. Many of the protists associate with bacterial symbionts, but hypotheses for their respective roles in nutrient exchange are based on genomes of only two such bacteria. To show how the ecological roles of protists and nutrient transfer with symbiotic bacteria can be elucidated by direct imaging, we combined stable isotope labeling ( 13 C-cellulose) of live termites with analysis of fixed hindgut microbes using correlated scanning electron microscopy, focused ion beam-scanning electron microscopy (FIB-SEM), transmission electron microscopy, and high resolution imaging mass spectrometry (NanoSIMS). We developed methods to prepare whole labeled cells on solid substrates, whole labeled cells milled with a FIB-SEM instrument to reveal cell interiors, and ultramicrotome sections of labeled cells for NanoSIMS imaging of 13 C enrichment in protists and associated bacteria. Our results show these methods have the potential to provide direct evidence for nutrient flow and suggest the oxymonad protist Oxymonas dimorpha phagocytoses and enzymatically degrades ingested wood fragments, and may transfer carbon derived from this to its surface bacterial symbionts.

59 BASIC BIOLOGICAL SCIENCES↗

Draft SOP for Sample Matching using ICP-MS

The purpose of this standard operating procedure (SOP) is to provide an assay for testing the hypothesis that two samples are from the same sub-population, which can mean they came from the same batch, set of replicate batches, or the same process. The outcome is a likelihood ratio, which should be used in combination with prior odds to determine the posterior odds of the two samples coming from the same sub-population. Note that the term “match” is not used because it is imprecise in the context of determining the relationship between two samples. Under this SOP, inductively coupled plasma mass spectrometer (ICP-MS) is used to generate elemental composition data, which is used to test the hypothesis that two samples come from the same sub-population. ICP-MS is a highly sensitive bulk analysis method. The quantity of sample required is ultimately determined by the instrumentation used and the elements selected for generating ROC curves. This SOP specifies that greater than 5 mg of sample be used to enable accurate weights to be obtained for the sample in tared 3 mL Teflon vials. However, we have conducted preliminary assays with our instrumentation that suggest that sample quantity can be reduced to 50 micrograms if elemental abundances are normalized to total metal content (see Step 10). We use ICP-MS because it is the most sensitive method for determining the concentration of the largest number of elements. Other elemental analysis methods could be used to generate data for this test (e.g., ICP-OES), but specific tests would be necessary to work out the SOP.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗