Search NASA⌕ Search

Engineering topics

Day, Anthony R.

Publications and source records attributed to Day, Anthony R..

At least 19 records

Migration of noble gas tracers at the site of an underground nuclear explosion at the Nevada National Security Site

As part of an underground gas migration study, two radioactive noble gases and two stable tracer gases were injected into a nuclear explosion test chimney and allowed to migrate naturally. Soil gas samples were collected from a series of boreholes and a range of depths from the shallow subsurface (3 meters) to deeper levels (~160 meters) over a period of eleven months. These samples have provided insights into the development and evolution of the subsurface plume and constrained the relative migration rates of the radioactive and stable gas species. Analysis of the samples concluded that the stable tracer SF6 was consistently enriched in the subsurface samples relative to the radiotracer 127Xe, but the ratios of SF6 and 37Ar remained similar throughout the samples.

Johnson, Christine M.↗

Stilbene cell development to improve radioxenon detection

A prototype stilbene beta cell has been designed, manufactured, tested, and compared to a plastic scintillator beta cell used for nuclear explosion monitoring of radioxenon. Measurements of the four isotopes of interest show similar responses for both the plastic scintillator and stilbene cell. However, we show that the stilbene cell exhibits minimal memory effect (0.043%), a capability that is of interest in nuclear explosion monitoring because it improves detection sensitivity, allowing for decreased time between measurements. The resolution of the stilbene cell is improved slightly (2.2 keV at 129 keV) when compared to the plastic scintillator cell. The efficiency of the stilbene cell is lower than that of the plastic by an average 15%. These results suggest that an improvement in light collection are needed. Pulse shape discrimination analysis decreases the minimum detectable concentration by 1%. The use of this geometry allows for a simple replacement of the plastic cells currently used in the field versus a complete overhaul of the existing radioxenon monitoring stations.

Sivels, Ciara B.↗

Direct low-energy measurement of 37Ar and 127Xe in a radiotracer gas using low-background proportional counters

A radiotracer gas with a blend of 37Ar and 127Xe was created for a gas migration experiment and was characterized at Pacific Northwest National Laboratory using ultra-low-background proportional counters. This paper describes the direct low-energy measurement of 37Ar and 127Xe in a dual-isotope sample. Using this low-energy technique, the dual-isotope radiotracer gas was determined to have activity concentrations of 483 Bq/cc and 1,435 Bq/cc for 37Ar and 127Xe, respectively, and a ratio of 1:3 on the reference date of 7/11/2016.

Mace, Emily K.↗

Development of a Low-Level 39Ar Calibration Standard – Analysis by Absolute Gas Counting Measurements Augmented with Simulation

This paper describes the generation of 39Ar, via reactor irritation of potassium carbonate, followed by quantitative analysis (length-compensated proportional counting) to yield calibration standards that are approximately 50 and 3 times atmospheric background levels. Measurements were performed in Pacific Northwest National Laboratory’s shallow underground counting laboratory studying the effect of gas density on beta-transport; these results are compared with simulation. The total expanded uncertainty of the specific activity for the ~50x 39Ar in P10 standard is 3.6% (k=2).

Absolute radiation measurement↗

Development of a Low-Level Ar-37 Calibration Standard

Argon-37 is an important environmental signature of an underground nuclear explosion. Producing and quantifying low-level 37Ar standards is an important step in the development of sensitive field measurement instruments for use during an On-Site Inspection, a key provision of the Comprehensive Nuclear-Test-Ban Treaty. This paper describes progress at Pacific Northwest National Laboratory (PNNL) in the development of a process to generate and quantify low-level 37Ar standard material, which can then be used to calibrate sensitive field systems at activities consistent with soil background levels. The 37Ar used for our work was generated using a laboratory-scale, high-energy neutron source to irradiate powdered samples of calcium carbonate. Small aliquots of 37Ar were then extracted from the head space of the irradiated samples. The specific activity of the head space samples, mixed with P10 (90% stable argon:10% methane by mole fraction) count gas, is then derived using the accepted Length-Compensated Internal-Source Proportional Counting method. Due to the low activity of the samples, a set of three Ultra-Low Background Proportional-Counters designed and fabricated at PNNL from radio-pure electroformed copper was used to make the measurements in PNNL’s shallow underground counting laboratory. Very low background levels (<10 counts/day) have been observed in the spectral region near the 37Ar emission feature at 2.8 keV. Two separate samples from the same irradiation were measured. The first sample was counted for 12 days beginning 28 days after irradiation, the second sample was counted for 24 days beginning 70 days after irradiation (the half-life of 37Ar is 35.0 days). Both sets of measurements were analyzed and yielded very similar results for the starting activity (~0.1 Bq) and activity concentration (0.15 mBq/ccSTP argon) after P10 count gas was added. A detailed uncertainty model was developed based on the ISO Guide to the Expression of Uncertainty in Measurement. This paper presents a discussion of the measurement analysis, along with assumptions and uncertainty estimates.

Absolute radiation measurement↗

39Ar/Ar measurements using ultra-low background proportional counters

Age dating groundwater and seawater using 39Ar/Ar ratios is an important tool to understand water mass flow rates and mean residence time. For modern or contemporary argon, the 39Ar activity is 1.8 mBq per liter of argon. Radiation measurements at these activity levels require ultra low-background detectors. Low-background proportional counters have been developed at Pacific Northwest National Laboratory. These detectors use traditional mixtures of argon and methane as counting gas, and the residual 39Ar from commercial argon has become a predominant source of background activity in these detectors. We demonstrated sensitivity to 39Ar by using geological or ancient argon from gas wells in place of commercial argon. The low level counting performance of these proportional counters is then demonstrated for sensitivities to 39Ar/Ar ratios sufficient to date water masses as old as 1000 years.

39Ar/Ar measurements using ultra-low background pr↗

A New Shallow Underground Gas-Proportional Counting Lab - First Results and Ar-37 Sensitivity

Abstract A new ultra-low-background proportional counter was recently developed with an internal volume of 100 ml and has been characterized at pressures from 1-10 atmospheres with P-10 (90% Ar, 10% methane) gas. This design, along with a counting system providing event digitization and passive and active shielding, has been developed to complement a new shallow underground laboratory (30 meters water-equivalent). Backgrounds and low-level reference materials have been measured, and system sensitivity for Ar-37 has been calculated.

argon-37↗

Development of an Absolute Gas-Counting Capability for Low to Medium Activities

ABSTRACT Pacific Northwest National Laboratory (PNNL) is developing a capability to measure the absolute activity concentration of various gaseous radionuclides using length-compensated proportional-counting methods. This capability will enable the validation and use of low-level, gaseous radionuclide calibration standards for use in PNNL’s shallow underground laboratory. Two sets of unequal length proportional counters have been fabricated. These detector assemblies operate on a static gas-fill principle, in contrast to continuous, flow-through configurations. One set of three counters has been fabricated using ultra-low background (ULB) electroformed copper and low-background fabrication methods. Once fully operational, these ULB counters will be used in PNNL’s shallow underground counting laboratory for analysis of gases with low activity concentrations < 1 Bq/cc. A second set of four unequal length counters has been fabricated from Oxygen-Free High-Conductivity Copper (OFHC) using similar low-background cleaning and assembly methods. These OFHC counters will be operated above ground in the analysis of gases with activity concentrations in the range of 1-10 Bq/cc. A gas delivery system is being developed to actively mix the analyte gas with an appropriate amount of count-gas and uniformly deliver it to the counters with high accuracy and repeatability. A description of both detector assemblies and gas delivery system will be given along with a preliminary uncertainty analysis of a simulated 0.05 Bq/cm3 gas measurement.

Williams, Richard M.↗

Initial Characterization of Unequal-Length, Low-Background Proportional Counters for Absolute Gas-Counting Applications

Abstract. Characterization of two sets of custom unequal length proportional counters is underway at Pacific Northwest National Laboratory (PNNL). These detectors will be used in measurements to determine the absolute activity concentration of gaseous radionuclides (e.g., 37Ar). A set of three detectors has been fabricated based on previous PNNL ultra-low-background proportional counters (ULBPC) designs and now operate in PNNL’s shallow underground counting laboratory. A second set of four counters has also been fabricated using clean assembly of OFHC copper components for use in an above-ground counting laboratory. Characterization of both sets of detectors is underway with measurements of background rates, gas gain, energy resolution, and shielding considerations. These results will be presented along with uncertainty estimates of future absolute gas counting measurements.

Mace, Emily K.↗

Calibration of an ultra-low-background proportional counter for measuring {sup 37}Ar

An ultra-low-background proportional counter design has been developed at Pacific Northwest National Laboratory (PNNL) using clean materials, primarily electro-chemically-purified copper. This detector, along with an ultra-low-background counting system (ULBCS), was developed to complement a new shallow underground laboratory (30 meters water-equivalent) at PNNL. The ULBCS design includes passive neutron and gamma shielding, along with an active cosmic-veto system. This system provides a capability for making ultra-sensitive measurements to support applications like age-dating soil hydrocarbons with {sup 14}C/{sup 3}H, age-dating of groundwater with {sup 39}Ar, and soil-gas assay for {sup 37}Ar to support On-Site Inspection (OSI). On-Site Inspection is a key component of the verification regime for the Comprehensive Nuclear-Test-Ban Treaty (CTBT). Measurements of radionuclides created by an underground nuclear explosion are valuable signatures of a Treaty violation. For OSI, the 35-day half-life of {sup 37}Ar, produced from neutron interactions with calcium in soil, provides both high specific activity and sufficient time for inspection before decay limits sensitivity. This work describes the calibration techniques and analysis methods developed to enable quantitative measurements of {sup 37}Ar samples over a broad range of proportional counter operating pressures. These efforts, along with parallel work in progress on gas chemistry separation, are expected to provide a significant new capability for {sup 37}Ar soil gas background studies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Controlling Low-Rate Signal Path Microdischarge for an Ultra-Low-Background Proportional Counter

ABSTRACT Pacific Northwest National Laboratory (PNNL) has developed an ultra-low-background proportional counter (ULBPC) made of high purity copper. These detectors are part of an ultra-low-background counting system (ULBCS) in the newly constructed shallow underground laboratory at PNNL (at a depth of ~30 meters water-equivalent). To control backgrounds, the current preamplifier electronics are located outside the ULBCS shielding. Thus the signal from the detector travels through ~1 meter of cable and is potentially susceptible to high voltage microdischarge and other sources of electronic noise. Based on initial successful tests, commercial cables and connectors were used for this critical signal path. Subsequent testing across different batches of commercial cables and connectors, however, showed unwanted (but still low) rates of microdischarge noise. To control this noise source, two approaches were pursued: first, to carefully validate cables, connectors, and other commercial components in this critical signal path, making modifications where necessary; second, to develop a custom low-noise, low-background preamplifier that can be integrated with the ULBPC and thus remove most commercial components from the critical signal path. This integrated preamplifier approach is based on the Amptek A250 low-noise charge-integrating preamplifier module. The initial microdischarge signals observed are presented and characterized according to the suspected source. Each of the approaches for mitigation is described, and the results from both are compared with each other and with the original performance seen with commercial cables and connectors.

low noise↗

Digital Pulse-Shape Discrimination Applied to an Ultra-Low-Background Gas-Proportional Counting System: First Results

Abstract A new ultra-low-background proportional counter (ULBPC) design was recently developed at Pacific Northwest National Laboratory (PNNL). This design, along with an ultra-low-background counting system (ULBCS) which provides passive and active shielding with radon exclusion, has been developed to complement a new shallow underground laboratory (~30 meters water-equivalent) constructed at PNNL. After these steps to mitigate dominant backgrounds (cosmic rays, external gamma-rays, radioactivity in materials), remaining background events do not exclusively arise from ionization of the proportional counter gas. Digital pulse-shape discrimination (PSD) is thus employed to further improve measurement sensitivity. In this work, a template shape is generated for each individual sample measurement of interest, a "self-calibrating" template. Differences in event topology can also cause differences in pulse shape. In this work, the temporal region analyzed for each event is refined to maximize background discrimination while avoiding unwanted sensitivity to event topology. This digital PSD method is applied to sample and background data, and initial measurement results from a biofuel methane sample are presented in the context of low-background measurements currently being developed.

signal processing, pulse-shape discrimination, pro↗

The Design, Construction, and Initial Characterization of an Ultra-Low-Background Gas-Proportional Counting System

ABSTRACT Over the past several years, the Pacific Northwest National Laboratory (PNNL) has developed an ultra-low background proportional counter (ULBPC) technology. The resulting detector is the product of an effort to produce a low-background, physically robust gas proportional counter for applications like radon emanation measurements, groundwater tritium, and 37Ar. In order to fully take advantage of the inherent low-background properties designed into the ULBPC, a comparably low-background dedicated counting system is required. An ultra-low-background counting system (ULBCS) was recently built in the new shallow underground laboratory at PNNL. With a design depth of 30 meters water-equivalent, the shallow underground laboratory provides approximately 100x fewer fast neutrons and 6x fewer muons than a surface location. The ULBCS itself provides additional shielding in the form of active anti-cosmic veto (via 2-in. thick plastic scintillator paddles) and passive borated poly (1 in.), lead (6 in.), and copper (~3 in.) shielding. This work will provide details on PNNL’s new shallow underground laboratory, examine the motivation for the design of the counting system, and provide results from the characterization of the ULBCS, including initial detector background.

ultra-low-background, proportional counters, shall↗

Empirical Correction of Crosstalk in a Low-Background Germanium γ–γ Analysis System

ABSTRACT The Pacific Northwest National Laboratory is currently developing a custom software suite capable of automating many of the tasks required to accurately analyze coincident signals within gamma spectrometer arrays. During the course of this work, significant crosstalk was identified in the energy determination for spectra collected with a new low-background intrinsic germanium (HPGe) array at PNNL. The HPGe array is designed for high detection efficiency, ultra-low-background performance, and sensitive gamma gamma coincidence detection. The first half of the array, a single cryostat containing 7 HPGe crystals, was recently installed into a new shallow underground laboratory facility. This update will present a brief review of the germanium array, describe the observed crosstalk, and present a straight-forward empirical correction that significantly reduces the impact of this crosstalk on the spectroscopic performance of the system.

coincidence↗

The Multi-sensor Airborne Radiation Survey (MARS) Instrument

The Multi-sensor Airborne Radiation Survey (MARS) project has developed a new single cryostat detector array design for high purity germanium (HPGe) gama ray spectrometers that achieves the high detection efficiency required for stand-off detection and actionable characterization of radiological threats. This approach, we found, is necessary since a high efficiency HPGe detector can only be built as an array due to limitations in growing large germanium crystals. Moreover, the system is ruggedized and shock mounted for use in a variety of field applications, including airborne and maritime operations.

array↗

A Germanium Array for Sample Measurements: Recent Results and New Analysis Methods

ABSTRACT The Pacific Northwest National Laboratory is finalizing construction of a 14-crystal intrinsic germanium (HPGe) array designed for high detection efficiency, ultra-low-background performance, and sensitive gamma gamma coincidence detection. Initial development of a custom software suite capable of automating many of the tasks required to accurately analyze coincident signals within close-geometry detector arrays will also be completed this year. The analysis capability is required to enable rapid interpretation of data collected with the low-background (HPGe) array. The status of final construction of the 2nd cryostat and the complete system will be discussed, as well as measurement results from independent operation of the 1st cryostat. Status of the CASCADES analysis development, including cross-talk correction and new techniques for efficiency calibration, are also presented.

Keillor, Martin E.↗

Measurement of 37Ar to support technology for On-site Inspection under the Comprehensive Nuclear-Test-Ban Treaty

On-Site Inspection (OSI) is a key component of the verification regime for the Comprehensive Nuclear-Test-Ban Treaty (CTBT). Measurements of radionuclide isotopes created by an underground nuclear explosion are a valuable signature of a Treaty violation. Argon-37 is produced from neutron interaction with calcium in soil, 40Ca(n,α)37Ar. For OSI, the 35-day half-life of 37Ar provides both high specific activity and sufficient time for completion of an inspection before decay limits sensitivity. This paper presents a low-background internal-source gas proportional counter with an 37Ar measurement sensitivity level equivalent to 45.1 mBq/SCM in whole air.

CTBT On-site Inspection↗