Combined Scanning Transmission Electron Microscopy Tilt- and Focal Series

In this study, a combined tilt- and focal series is proposed as a new recording scheme for high-angle annular dark-field scanning transmission electron microscopy (STEM) tomography. Three-dimensional (3D) data were acquired by mechanically tilting the specimen, and recording a through-focal series at each tilt direction. The sample was a whole-mount macrophage cell with embedded gold nanoparticles. The tilt focal algebraic reconstruction technique (TF-ART) is introduced as a new algorithm to reconstruct tomograms from such combined tilt- and focal series. The feasibility of TF-ART was demonstrated by 3D reconstruction of the experimental 3D data. The results were compared with a conventional STEM tilt series of a similar sample. The combined tilt- and focal series led to smaller missing wedge artifacts, and a higher axial resolution than obtained for the STEM tilt series, thus improving on one of the main issues of tilt series-based electron tomography.

Dahmen, Tim↗

The three-dimensional point spread function of aberration-corrected scanning transmission electron microscopy

Aberration-correction reduces the depth of field in scanning transmission electron microscopy and allows three-dimensional imaging by depth-sectioning. This imaging mode offers the potential for sub- ngstrom lateral resolution and nanometer-scale depth sensitivity. For biological samples, which may be many microns across and where high lateral resolution may not always be needed, optimizing the depth resolution even at the expense of lateral resolution may be desired, aiming to image through thick specimens. Although there has been extensive work examining and optimizing the probe formation in two-dimensions, there is less known about the probe shape along the optical axis. Here we examine the probe shape in three-dimensions in an attempt to better understand the depth-resolution in this mode. We present examples of how aberrations change the probe shape in three-dimensions and demonstrate that off-axial aberrations may need to be considered for focal series of large areas. We show that oversized or annular apertures theoretically improve the vertical resolution for 3D imaging of nanoparticles. When imaging nanoparticles of several nanometer size, the regular STEM can thereby be optimized such that the vertical full width at half maximum approaches that of the aberration corrected STEM with a standard aperture.

99 GENERAL AND MISCELLANEOUS↗

Three-dimensional scanning transmission electron microscopy of biological specimens

A three-dimensional (3D) reconstruction of the cytoskeleton and a clathrin-coated pit in mammalian cells has been achieved from a focal-series of images recorded in an aberration-corrected scanning transmission electron microscope (STEM). The specimen was a metallic replica of the biological structure comprising Pt nanoparticles 2 - 3 nm in diameter, with a high stability under electron beam radiation. The 3D dataset was processed by an automated deconvolution procedure. The lateral resolution was 1.1 nm, set by pixel size. Particles differing by only 10 nm in vertical position were identified as separate objects with greater than 20% dip in contrast between them. We refer to this value as the axial resolution of the deconvolution or reconstruction, the ability to recognize two objects, which were unresolved in the original data set. The precision of the height determination was 0.2 nm. The resolution of the reconstruction is comparable to that achieved by tilt-series transmission electron microscopy (TEM). However, the focal-series method does not require mechanical tilting and is therefore much faster. 3D STEM images were also recorded of the Golgi ribbon in conventional thin sections containing 3T3 cells with a comparable axial resolution in the deconvolved data set.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Microfluidic system for transmission electron microscopy

We present a microfluidic system that maintains liquid flow in a specimen chamber for (scanning) transmission electron microscope ((S)TEM) imaging. The specimen chamber consists of two ultra-thin silicon nitride windows supported by silicon microchips. They are placed in a specimen holder that seals the sample from the vacuum in the electron microscope, and incorporates tubing to and from the sample connected to a syringe pump outside the microscope. Using results obtained from fluorescence microscopy of microspheres flowing through the system, an equation to characterize the liquid flow through the system was calibrated. Gold nanoparticles of diameters of 30 and 100 nm moving in liquid were imaged with a 200 kV STEM. It was concluded that despite strong influences from Brownian motion, and sensitivity to small changes in the depth of the bypass channel, the electron microscopy flow data matched the calculated flow speed within an order of magnitude. The system allows for rapid (within a minute) liquid exchange, which can potentially be used, for example, to investigate the response of specimens, e.g., eukaryotic-, or bacterial cells, to certain stimuli.

99 GENERAL AND MISCELLANEOUS↗

Atmospheric pressure scanning transmission electron microscopy

Scanning transmission electron microscope (STEM) images of gold nanoparticles (2.1 nm average diameter) at atmospheric pressure have been recorded through a 0.36 mm thick mixture of CO, O2 and He. This was accomplished using a reaction cell consisting of two electron-transparent silicon nitride membranes mounted on a specially designed specimen rod. Gas flow occurred through plastic tubing from the outside of the microscope to the specimen region and back. Gold nanoparticles of a full width half maximum diameter of 1.0 nm were visible above the background noise and the achieved resolution was 0.5 nm in accordance with calculations of the beam broadening.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Correlative fluorescence microscopy and liquid STEM of proteins labeled with quantum dots on intact cells.

Liquid scanning transmission electron microscopy (liquid STEM) was used to image individual quantum dots bound to receptors in COS7 cells. The same regions on intact fixed cells were imaged both with fluorescence microscopy and liquid STEM. The obtained spatial resolution on was 3 nm. The resolution was sufficient to discriminate between quantum dots and gold nanoparticles for double labeling applications.

59 BASIC BIOLOGICAL SCIENCES↗

Electron microscopy through micrometers thick water layers

Scanning transmission electron microscopy can be used to image specimens in water layers of several micrometers thickness, sufficiently thick to contain eukaryotic cells. We determined the resolution obtained on gold nanoparticles above and below water layers with thicknesses ranging from 1.3 13 m. The best achieved resolution values were 1.4 nm and 9 nm, above 3.3 m and below 1.3 m of water, respectively. A theoretical model included probe broadening and Monte Carlo simulations were developed to describe the resolution as function of the sample parameters.

99 GENERAL AND MISCELLANEOUS↗