PETN Sample Preparation Safety Limits
27 psi has been determined to be the maximum allowable pressure for contact operations with PETN at LLNL. Pressures above this limit can be tested, but samples must be prepared via remote handling operations. This document summarizes the safety review and discussion that took place at LLNL to define this pressure limit.