Organic Vacuum Pump Fluids for the Vacuum Pumping of Fusion Power Plants

Vacuum pumps are the heart of the fusion fuel cycle, but most currently proposed pumping technologies are not capable of handling the required flow rates and vacuum pressures. Oil-containing vacuum pumps can readily meet the flow requirements, but vacuum fluids will degrade in fusion-relevant environments due to contact with tritium and exposure to high-energy radiation. Here, in this study, we describe a methodology to screen vacuum fluid candidates and purify these candidate fluids post oxidation, post exposure to deuterium, and post exposure to gamma radiation (<7.5 MGy) to simulate a process in which vacuum fluids can be recovered and regenerated during the fusion fuel cycle. A series of oils, including a highly purified mineral oil, phenyl silicone oil, and a polyphenyl ether, are shown to be suitable candidates for vacuum pumping. Additionally, we describe a simple purification methodology to remove oxidized functionalities and the associated isotopologues induced by contact with deuterium from the candidate vacuum fluids This purification methodology can also be applied to radiological damage with moderate effect. Finally, we demonstrate that the sorbents can be regenerated through electromagnetic microwave digestion.

oxidation↗

Photoluminescence Induced in Mineral Oil by Ionizing Radiation

We have studied photoluminescence (PL) properties of vacuum pump mineral oil as a function of the type and intensity of ionizing radiation exposure. The mineral oil has a simple aliphatic structure, which possesses no chromophore in the traditional sense. Unexpected PL in the mineral oil has characteristic features such as variation of the emission peak wavelength depending on the excitation wavelength and intensity dramatically increasing with radiation dose. The observed behavior can be understood in the framework of a previously suggested model introducing aggregation-induced PL and the formation of conjugated clusters comprising nontraditional chromophores. Our findings can be used for the development of optical sensors for real-time monitoring of oil utilized in vacuum pumps in nuclear fusion reactors.

Bliznyuk, Valery N.↗

Functionalized Polymer Thin Films for Plutonium Capture and Isotopic Screening from Aqueous Sources

The rapid screening of plutonium from aqueous sources remains a critical challenge for nuclear nonproliferation efforts. The determination of trace-level Pu isotopes in water requires offsite sample preparation and analysis; therefore, new methods that combine plutonium purification, concentration, and isotopic screening in a fieldable detection system will provide an invaluable tool for nuclear safeguards. This contribution describes the development and characterization of thin polymer-ligand films for the isolation and concentration of waterborne Pu for direct spectroscopic analyses. Submicron thin films were prepared through spin coating onto Si wafers and consisted of combinations of polystyrene (PS) with dibenzoylmethane, thenoyltrifluoroacetone, and di(2-ethylhexyl)phosphoric acid (HDEHP). Pu uptake studies from solutions at pH from 2.3 to 6.3 indicated that only films containing HDEHP exhibited significant recovery of Pu. High alpha spectroscopy peak energy resolutions were achieved for PS-HDEHP films over a range of film thicknesses from 30 to 250 nm. Furthermore, a separate study was performed to evaluate uptake from a primarily Pu(V) solution where it was observed that doubling the HDEHP loading in the film increased uptake of Pu by an order of magnitude. X-ray photoelectron spectroscopy (XPS) analysis revealed that HDEHP was highly concentrated within the first few nanometers of the film at the higher loading. XPS analysis also revealed that, in the presence of water, HDEHP was stripped from the surface layer of the film at circumneutral pH. While significant losses of ligand were seen in all samples, higher loadings of HDEHP resulted in measurable amounts of ligand retained after a 12-h soak in water. Findings of this study are being used to guide the development of thin-film composite membrane-based detection methods for the rapid, fieldable analysis of Pu in water.

36 MATERIALS SCIENCE↗