An interleave retrieval method for oversampled limb scans
Rodgers presents a general approach for error analysis of retrievals based on a linearization of the retrieval problem. This approach allows calculation of retrieval error from uncertainties in the input radiances and in each of the forward radiance model parameters. These terms are weighted according to the sensitivity of the retrieval to each of them. We use this framework to describe the results of an error analysis performed on HALOE data. This paper will show the effect of using over sampled profile data and an interleave retrieval technique by application of formal error analysis.